Lung clearance index is a sensitive, repeatable and practical measure of airways disease in adults with cystic fibrosis

Open access
Horsley, A R, Gustafsson, P M, Macleod, K A, Saunders, C, Greening, A P, Porteous, D J, Davies, J C, Cunningham, S, Alton, E W F W, Innes, J A · 2007 · Thorax

Abstract

BACKGROUND: Lung clearance index (LCI) is a sensitive marker of early lung disease in children but has not been assessed in adults. Measurement is hindered by the complexity of the equipment required. The aims of this study were to assess performance of a novel gas analyser (Innocor) and to use it as a clinical tool for the measurement of LCI in cystic fibrosis (CF). METHODS: LCI was measured in 48 healthy adults, 12 healthy school-age children and 33 adults with CF by performing an inert gas washout from 0.2% sulfur hexafluoride (SF6). SF6 signal:noise ratio and 10-90% rise time of Innocor were compared with a mass spectrometer used in similar studies in children. RESULTS: Compared with the mass spectrometer, Innocor had a superior signal:noise ratio but a slower rise time (150 ms vs 60 ms) which may limit its use in very young children. Mean (SD) LCI in healthy adults was significantly different from that in patients with CF: 6.7 (0.4) vs 13.1 (3.8), p<0.001. Ten of the patients with CF had forced expiratory volume in 1 s > or = 80% predicted but only one had a normal LCI. LCI repeats were reproducible in all three groups of subjects (mean intra-visit coefficient of variation ranged from 3.6% to 5.4%). CONCLUSIONS: Innocor can be adapted to measure LCI and affords a simpler alternative to a mass spectrometer. LCI is raised in adults with CF with normal spirometry, and may prove to be a more sensitive marker of the effects of treatment in this group.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/thx.2007.082628

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 219

Metadata

Authors
Horsley, A. R., Gustafsson, P. M., Macleod, K. A., Saunders, C., Greening, A. P., Porteous, D. J., Davies, J. C., Cunningham, S., Alton, E. W. F. W., & Innes, J. A.
Venue
Thorax
Publisher
BMJ
Published
2007-09-17
Volume
63
Issue
2
Pages
135-140
ISSN
0040-6376 (ISSN-L)
OpenAlex
W2145135941
Cited by
219
References
4
FWCI
6.77
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Lung clearance index is a sensitive, repeatable and practical measure of airways disease in adults with cystic fibrosis. https://app.cochat.ai/papers/10.1136/thx.2007.082628
The paper
Horsley, A. R., Gustafsson, P. M., Macleod, K. A., Saunders, C., Greening, A. P., Porteous, D. J., Davies, J. C., Cunningham, S., Alton, E. W. F. W., & Innes, J. A. (2007). Lung clearance index is a sensitive, repeatable and practical measure of airways disease in adults with cystic fibrosis. Thorax. https://doi.org/10.1136/thx.2007.082628

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.