Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 535

The DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.

Using the lower limit of normal for the FEV1/FVC ratio reduces the misclassification of airway obstruction

Open access
Swanney, M P, Ruppel, G, Enright, P L, Pedersen, O F, Crapo, R O, Miller, M R, Jensen, R L, Falaschetti, E, Schouten, J P, Hankinson, J L, Stocks, J, Quanjer, P H·2008·Thorax

Abstract

AIM: The prevalence of airway obstruction varies widely with the definition used. OBJECTIVES: To study differences in the prevalence of airway obstruction when applying four international guidelines to three population samples using four regression equations. METHODS: We collected predicted values for forced expiratory volume in 1 s/forced vital capacity (FEV(1)/FVC) and its lower limit of normal (LLN) from the literature. FEV(1)/FVC from 40 646 adults (including 13 136 asymptomatic never smokers) aged 17-90+years were available from American, English and Dutch population based surveys. The prevalence of airway obstruction was determined by the LLN for FEV(1)/FVC, and by using the Global Initiative for Chronic Obstructive Lung Disease (GOLD), American Thoracic Society/European Respiratory Society (ATS/ERS) or British Thoracic Society (BTS) guidelines, initially in the healthy subgroup and then in the entire population. RESULTS: The LLN for FEV(1)/FVC varied between prediction equations (57 available for men and 55 for women), and demonstrated marked negative age dependency. Median age at which the LLN fell below 0.70 in healthy subjects was 42 and 48 years in men and women, respectively. When applying the reference equations (Health Survey for England 1995-1996, National Health and Nutrition Examination Survey (NHANES) III, European Community for Coal and Steel (ECCS)/ERS and a Dutch population study) to the selected population samples, the prevalence of airway obstruction in healthy never smokers aged over 60 years varied for each guideline: 17-45% of men and 7-26% of women for GOLD; 0-18% of men and 0-16% of women for ATS/ERS; and 0-9% of men and 0-11% of women for BTS. GOLD guidelines caused false positive rates of up to 60% when applied to entire populations. CONCLUSIONS: Airway obstruction should be defined by FEV(1)/FVC and FEV(1) being below the LLN using appropriate reference equations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/thx.2008.098483

Cites

63 of 63 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 63 references

Cited by

See all 535

Metadata

Authors
Swanney, M. P., Ruppel, G., Enright, P. L., Pedersen, O. F., Crapo, R. O., Miller, M. R., Jensen, R. L., Falaschetti, E., Schouten, J. P., Hankinson, J. L., Stocks, J., & Quanjer, P. H.
Venue
Thorax
Publisher
BMJ
Published
2008-05-20
Volume
63
Issue
12
Pages
1046-1051
ISSN
0040-6376 (ISSN-L)
OpenAlex
W2145153937
Cited by
535
References
63
FWCI
25.60
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Using the lower limit of normal for the FEV1/FVC ratio reduces the misclassification of airway obstruction. https://app.cochat.ai/papers/10.1136/thx.2008.098483
The paper
Swanney, M. P., Ruppel, G., Enright, P. L., Pedersen, O. F., Crapo, R. O., Miller, M. R., Jensen, R. L., Falaschetti, E., Schouten, J. P., Hankinson, J. L., Stocks, J., & Quanjer, P. H. (2008). Using the lower limit of normal for the FEV1/FVC ratio reduces the misclassification of airway obstruction. Thorax. https://doi.org/10.1136/thx.2008.098483

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.