The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
High-intensity versus low-intensity non-invasive ventilation in patients with stable hypercapnic COPD: a randomised crossover trial
Open accessAbstract
RATIONALE: The conventional approach of low-intensity non-invasive positive pressure ventilation (NPPV) produces only minimal physiological and clinical benefits in patients with stable hypercapnic chronic obstructive pulmonary disease (COPD). OBJECTIVES: To determine whether the novel approach of high-intensity NPPV is superior to low-intensity NPPV in controlling nocturnal hypoventilation. METHODS: A randomised controlled crossover trial comparing 6 weeks of high-intensity NPPV (using controlled ventilation with mean inspiratory pressures of 28.6+/-1.9 mbar) with low-intensity NPPV (using assisted ventilation with mean inspiratory pressures of 14.6+/-0.8 mbar) was performed in 17 patients with severe stable hypercapnic COPD. RESULTS: Two patients refused low-intensity NPPV and two patients dropped out while on low-intensity NPPV. Thirteen patients (mean forced expiratory volume in 1 s (FEV(1)) 0.76+/-0.29 l) completed the trial. High-intensity NPPV produced higher pneumotachographically-measured expiratory volumes, with a mean treatment effect of 96 ml (95% CI 23 to 169) (p=0.015). This resulted in a mean treatment effect on nocturnal arterial carbon dioxide tension (Paco(2)) of -9.2 mm Hg (95% CI -13.7 to -4.6) (p=0.001) in favour of high-intensity NPPV. Daily use of NPPV was increased in high-intensity NPPV compared with low-intensity NPPV, with a mean difference of 3.6 h/day (95% CI 0.6 to 6.7) (p=0.024). In addition, compared with baseline, only high-intensity NPPV resulted in significant improvements in exercise-related dyspnoea, daytime Paco(2), FEV(1), vital capacity and the Severe Respiratory Insufficiency Questionnaire Summary Score. CONCLUSIONS: High-intensity NPPV is better tolerated by patients with severe chronic hypercapnic COPD and has been shown to be superior to the conventional and widely-used form of low-intensity NPPV in controlling nocturnal hypoventilation. High-intensity NPPV therefore offers a new promising therapeutic option for these patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Psychophysical bases of perceived exertion
BORG, G. A. V. (1982) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198205000-00012 · Cited by 16,580
Vestbo, J., Hurd, S. S., Agustí, A. G., Jones, P. W., Vogelmeier, C., Anzueto, A., Barnes, P. J., Fabbri, L. M., Martinez, F. J., Nishimura, M., et al. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201204-0596pp · Cited by 15,983
Lung volumes and forced ventilatory flows
Quanjer, P. H., Tammeling, G. J., Cotes, J. E., Pedersen, O. F., Peslin, R., & Yernault, J.-C. (1993) · European Respiratory Journal · doi:10.1183/09041950.005s1693 · Cited by 5,318
Rabe, K. F., Hurd, S., Anzueto, A., Barnes, P. J., Buist, S. A., Calverley, P., Fukuchi, Y., Jenkins, C., Rodriguez-Roisin, R., van Weel, C., et al. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200703-456so · Cited by 4,925
Celli, B. R., Cote, C. G., Marin, J. M., Casanova, C., Montes de Oca, M., Mendez, R. A., Pinto Plata, V., & Cabral, H. J. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa021322 · Cited by 4,015
(1993) · PubMed · Cited by 3,827
Two-, six-, and 12-minute walking tests in respiratory disease.
Butland, R. J., Pang, J., Gross, E. R., Woodcock, A. A., & Geddes, D. M. (1982) · BMJ · doi:10.1136/bmj.284.6329.1607 · Cited by 1,668
Rodríguez, R. (2007) · Cited by 1,391
Management of Chronic Obstructive Pulmonary Disease
Sutherland, E. R., & Cherniack, R. M. (2004) · New England Journal of Medicine · doi:10.1056/nejmra030415 · Cited by 563
Meecham Jones, D. J., Paul, E. A., Jones, P. W., & Wedzicha, J. A. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.152.2.7633704 · Cited by 479
Clini, E., Sturani, C., Rossi, A., Viaggi, S., Corrado, A., Donner, C. F., & Ambrosino, N. (2002) · European Respiratory Journal · doi:10.1183/09031936.02.02162001 · Cited by 447
Nocturnal non-invasive nasal ventilation in stable hypercapnic COPD: a randomised controlled trial
McEvoy, R. D., Pierce, R. J., Hillman, D., Esterman, A., Ellis, E. E., Catcheside, P. G., O'Donoghue, F. J., Barnes, D. J., Grunstein, R. R., & on behalf of the Australian trial of non-invasive Ventilation in Chronic Airflow Limitation (AVCAL) Study Group (2009) · Thorax · doi:10.1136/thx.2008.108274 · Cited by 418
Pizov, R. (2004) · Survey of Anesthesiology · doi:10.1097/01.sa.0000144225.72154.cf · Cited by 392
Casanova, C., Celli, B. R., Tost, L., Soriano, E., Abreu, J., Velasco, V., & Santolaria, F. (2000) · Chest · doi:10.1378/chest.118.6.1582 · Cited by 350
Average Volume-Assured Pressure Support in Obesity Hypoventilation
Storre, J. H., Seuthe, B., Fiechter, R., Milioglou, S., Dreher, M., Sorichter, S., & Windisch, W. (2006) · Chest · doi:10.1378/chest.130.3.815 · Cited by 290
Self-citationWindisch, W., Freidel, K., Schucher, B., Baumann, H., Wiebel, M., Matthys, H., & Petermann, F. (2003) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(03)00088-x · Cited by 232
Self-citationImpact of home mechanical ventilation on health-related quality of life
Windisch, W. (2008) · European Respiratory Journal · doi:10.1183/09031936.00066407 · Cited by 195
Self-citationHigh-intensity non-invasive positive pressure ventilation for stable hypercapnic COPD
Windisch, W., Haenel, M., Storre, J. H., & Dreher, M. (2009) · International Journal of Medical Sciences · doi:10.7150/ijms.6.72 · Cited by 182
Self-citationJanssens, J.-P., Metzger, M., & Sforza, E. (2009) · Respiratory Medicine · doi:10.1016/j.rmed.2008.03.013 · Cited by 175
Windisch, W., Kostić, S., Dreher, M., Virchow, J. C., & Sorichter, S. (2005) · Chest · doi:10.1378/chest.128.2.657 · Cited by 173
Self-citationA Meta-analysis of Nocturnal Noninvasive Positive Pressure Ventilation in Patients With Stable COPD
Wijkstra, P. J., Lacasse, Y., Guyatt, G. H., Casanova, C., Gay, P. C., Meecham Jones, J., & Goldstein, R. S. (2003) · Chest · doi:10.1378/chest.124.1.337 · Cited by 171
Systematic review of noninvasive positive pressure ventilation in severe stable COPD
Kolodziej, M., Jensen, L., Rowe, B. H., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00145106 · Cited by 140
Budweiser, S., Jörres, R. A., Riedl, T., Heinemann, F., Hitzl, A. P., Windisch, W., & Pfeifer, M. (2007) · CHEST Journal · doi:10.1378/chest.06-2124 · Cited by 132
Self-citationNoninvasive ventilation during walking in patients with severe COPD: a randomised cross-over trial
Dreher, M., Storre, J. H., & Windisch, W. (2007) · European Respiratory Journal · doi:10.1183/09031936.00075806 · Cited by 126
Self-citationPeak or plateau maximal inspiratory mouth pressure: which is best?
Windisch, W., Hennings, E., Sorichter, S., Hamm, H., & Criée, C.-P. (2004) · European Respiratory Journal · doi:10.1183/09031936.04.00136104 · Cited by 104
Self-citationNormocapnia during nIPPV in chronic hypercapnic COPD reduces subsequent spontaneous PaCO2
Windisch, W., VOGEL, M., Sorichter, S., et al. (2002) · Respiratory Medicine · doi:10.1053/rmed.2002.1326 · Cited by 96
Self-citationNocturnal non-invasive positive pressure ventilation: Physiological effects on spontaneous breathing
Windisch, W., Dreher, M., Storre, J. H., & Sorichter, S. (2005) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2005.05.017 · Cited by 81
Self-citationPhysiological and clinical effects of diurnal noninvasive ventilation in hypercapnic COPD
Orlando Díaz, P., Bégin, P., Andresen, M., Prieto, M. E., Castillo, C., Jorge Jorquera, A., & Lisboa, C. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00033905 · Cited by 80
Windisch, W., Budweiser, S., Heinemann, F., Pfeifer, M., & Rzehak, P. (2008) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2007.09.009 · Cited by 72
Self-citationClinical impact of leak compensation during non-invasive ventilation
Storre, J. H., Bohm, P., Dreher, M., & Windisch, W. (2009) · Respiratory Medicine · doi:10.1016/j.rmed.2009.04.020 · Cited by 57
Self-citationWeight Gain in Cachectic COPD Patients Receiving Noninvasive Positive-Pressure Ventilation
Budweiser, S., Heinemann, F., Meyer, K., Wild, P. J., & Pfeifer, M. (2006) · Respiratory Care · doi:10.4187/respcare.06510126 · Cited by 55
Dreher, M., Doncheva, E., Schwoerer, A., Walterspacher, S., Sonntag, F., Kabitz, H., & Windisch, W. (2008) · Respiration · doi:10.1159/000187717 · Cited by 53
Self-citationWijkstra, P. J. (2003) · Respiratory Medicine · doi:10.1016/s0954-6111(03)00163-x · Cited by 29
Management of Chronic Obstructive Pulmonary Disease
Ewart, R. M. (2004) · JAMA · doi:10.1001/jama.291.9.1066-a · Cited by 14
Cited by
Köhnlein, T., Windisch, W., Köhler, D., Drabik, A., Geiseler, J., Hartl, S., Karg, O., Laier-Groeneveld, G., Nava, S., Schönhofer, B., et al. (2014) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(14)70153-5 · Cited by 815
Self-citationErgan, B., Oczkowski, S., Rochwerg, B., Carlucci, A., Chatwin, M., Clini, E., Elliott, M., Gonzalez-Bermejo, J., Hart, N., Lujan, M., et al. (2019) · European Respiratory Journal · doi:10.1183/13993003.01003-2019 · Cited by 306
Self-citationAdler, D., Perrig, S., Takahashi, H., Espa, F., Rodenstein, D., Pépin, J. L., & Janssens, J.-P. (2012) · Sleep and Breathing · doi:10.1007/s11325-011-0605-y · Cited by 104
The growing role of noninvasive ventilation in patients requiring prolonged mechanical ventilation
Hess, D. R. (2012) · Respiratory Care · doi:10.4187/respcare.01692 · Cited by 59
The right interface for the right patient in noninvasive ventilation: a systematic review
Pierucci, P., Portacci, A., Carpagnano, G. E., Banfi, P., Crimi, C., Misseri, G., & Gregoretti, C. (2022) · Expert Review of Respiratory Medicine · doi:10.1080/17476348.2022.2121706 · Cited by 40
Metadata
- Authors
- Dreher, M., Storre, J. H., Schmoor, C., & Windisch, W.
- Venue
- Thorax
- Publisher
- BMJ
- Published
- 2010-04-01
- Volume
- 65
- Issue
- 4
- Pages
- 303-308
- ISSN
- 0040-6376 (ISSN-L)
- OpenAlex
- W2101918266
- Cited by
- 308
- References
- 34
- FWCI
- 11.31
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.