CoChat

Atrophy and hypertrophy signalling of the quadriceps and diaphragm in COPD

Doucet, M., Dube, A., Joanisse, D. R., Debigare, R., Michaud, A., Pare, M.-E., Vaillancourt, R., Frechette, E., Maltais, F. · 2010 · Thorax
Cited by 55

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Factors involved in the regulation of muscle mass in chronic obstructive pulmonary disease (COPD) are still poorly understood. Comparing the signalisation involved in muscle mass regulation between two muscles with different levels of activation within the same subjects is an interesting strategy to tease out the impact of local (muscle activity) versus systemic factors in the regulation of muscle mass. A study was undertaken to measure and compare the protein levels of p-AKT, AKT, Atrogin-1, p-p70S6K, p-4E-BP1, p-GSK3β as well as the mRNA expression of Atrogin-1, MuRF1 and FoxO-1 in the quadriceps and the diaphragm of 12 patients with COPD and 7 controls with normal lung function. METHODS: Diaphragm biopsies were obtained during thoracic surgery and quadriceps samples were obtained from needle biopsies. Protein content and mRNA expression were measured by western blot and quantitative PCR, respectively. RESULTS: Increased mRNA expressions of Atrogin-1, MuRF1 and FoxO-1 were found in the quadriceps compared with the diaphragm only in patients with COPD. The quadriceps/diaphragm ratio for MuRF1 was higher in COPD. The protein level of p-p70S6K was decreased in the quadriceps compared with the diaphragm in patients with COPD. The quadriceps/diaphragm ratios of p-p70S6K and p-GSK3β were lower in patients with COPD than in controls. CONCLUSIONS: These results indicate a greater susceptibility to a catabolic/anabolic imbalance favouring muscle atrophy in the quadriceps compared with the diaphragm in patients with COPD. The balance between the atrophy and hypertrophy signalling is inhomogeneous between respiratory and lower limb muscles, suggesting that local factors are likely to be involved in the regulation of muscle mass in COPD.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/thx.2009.133827

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 55

Metadata

Authors
Doucet, M., Dube, A., Joanisse, D. R., Debigare, R., Michaud, A., Pare, M.-E., Vaillancourt, R., Frechette, E., & Maltais, F.
Venue
Thorax
Publisher
BMJ
Published
2010-10-21
Volume
65
Issue
11
Pages
963-970
ISSN
0040-6376 (ISSN-L)
OpenAlex
W2166774855
Cited by
55
References
11
FWCI
1.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.