Nocturnal monitoring of home non-invasive ventilation: the contribution of simple tools such as pulse oximetry, capnography, built-in ventilator software and autonomic markers of sleep fragmentation
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Complex respiratory events, which may have a detrimental effect on both quality of sleep and control of nocturnal hypoventilation, occur during sleep in patients treated with non-invasive ventilation (NIV). Among these events are patient-ventilator asynchrony, increases in upper airway resistance (with or without increased respiratory drive) and leaks. Detection of these events is important in order to select the most appropriate ventilator settings and interface. Simple tools can provide important information when monitoring NIV. Pulse oximetry is important to ensure that adequate oxygen saturation is provided and to detect either prolonged or short and recurrent desaturations. However, the specificity of pulse oximetry tracings during NIV is low. Transcutaneous capnography helps discriminate between hypoxaemia related to ventilation/perfusion mismatch and hypoventilation, documents correction of nocturnal hypoventilation and may detect ventilator-induced hyperventilation, a possible cause for central apnoea/hypopnoea and glottic closure. Data provided by ventilator software help the clinician by estimating ventilation, tidal volume, leaks and the rate of inspiratory or expiratory triggering by the patient, although further validation of these signals by independent studies is indicated. Finally, autonomic markers of sympathetic tone using signals such as pulse wave amplitude of the pulse oximetry signal can provide reliable information of sleep fragmentation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sériès, F., Kimoff, R. J., Morrison, D., Leblanc, M. H., Smilovitch, M., Howlett, J., Logan, A. G., Floras, J. S., & Bradley, T. D. (2005) · Chest · doi:10.1378/chest.127.5.1507 · Cited by 83
Cited by
Jilwan, F. N., Escourrou, P., Garcia, G., Jaïs, X., Humbert, M., & Roisman, G. (2013) · Chest · doi:10.1378/chest.11-3124 · Cited by 115
Adler, D., Perrig, S., Takahashi, H., Espa, F., Rodenstein, D., Pépin, J. L., & Janssens, J.-P. (2012) · Sleep and Breathing · doi:10.1007/s11325-011-0605-y · Cited by 104
“Monitoring pulse oximetry (SpO2) and transcutaneous capnography (PtcCO2) alone do not explore this aspect of therapy adequately.”
BackgroundInfluentialSelf-citationLong-Term Ventilation in Neuromuscular Patients: Review of Concerns, Beliefs, and Ethical Dilemmas
Crimi, C., Pierucci, P., Carlucci, A., Cortegiani, A., & Gregoretti, C. (2019) · Respiration · doi:10.1159/000495941 · Cited by 46
Metadata
- Authors
- Janssens, J.-P., Borel, J.-C., Pepin, J.-L., & on behalf of the SomnoNIV Group
- Venue
- Thorax
- Publisher
- BMJ
- Published
- 2010-10-22
- Volume
- 66
- Issue
- 5
- Pages
- 438-445
- ISSN
- 0040-6376 (ISSN-L)
- OpenAlex
- W2145136340
- Cited by
- 251
- References
- 1
- FWCI
- 7.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.