CoChat

Do large volume spacer devices reduce the systemic effects of high dose inhaled corticosteroids?

Open access
Brown, P H, Blundell, G, Greening, A P, Crompton, G K · 1990 · Thorax
Cited by 110

The DOI matches its Crossref record.

Abstract

When used in high doses, inhaled corticosteroids may cause suppression of the hypothalamo-pituitary-adrenal axis. The influence of the mode of drug inhalation on the degree of this suppression is not clear. Hypothalamo-pituitary-adrenal function was assessed by measurement of 0900 h serum cortisol concentrations, a short tetracosactrin test, and 24 hour urine free cortisol excretion in 48 adults with asthma taking 1500-2500 micrograms beclomethasone dipropionate daily via a metered dose aerosol. Twelve patients had hypothalamo-pituitary-adrenal suppression, as judged by subnormal results from at least two of the three tests or (in one patient) by an abnormal insulin stress test response. These patients then changed to inhaling the same dose of beclomethasone dipropionate through a 750 ml spacer device (Volumatic). The endocrine tests were repeated from nine days to eight weeks later in 10 patients. Comparison with initial values showed that adding the spacing device caused an increase in the median 0900 h cortisol concentration from 126 nmol/l to 398 nmol/l, in the post-tetracosactrin cortisol concentration from 402 nmol/l to 613 nmol/l and in 24 hour urine free cortisol excretion from 54 nmol to 84 nmol. The rise in serum cortisol concentration in response to tetracosactrin did not change. Evidence of persisting hypothalamo-pituitary-adrenal axis suppression was present in only four of the 10 patients; the most pronounced improvements in function tended to occur in those who had never required long term oral corticosteroids. The results from this uncontrolled study suggest that asthmatic patients taking high dose beclomethasone dipropionate may minimise adverse effects by using a large volume spacer device.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/thx.45.10.736

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 110

Metadata

Authors
Brown, P. H., Blundell, G., Greening, A. P., & Crompton, G. K.
Venue
Thorax
Publisher
BMJ
Published
1990-10-01
Volume
45
Issue
10
Pages
736-739
ISSN
0040-6376 (ISSN-L)
OpenAlex
W2150353636
Cited by
110
References
0
FWCI
9.26
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Do large volume spacer devices reduce the systemic effects of high dose inhaled corticosteroids? https://app.cochat.ai/papers/10.1136/thx.45.10.736
The paper
Brown, P. H., Blundell, G., Greening, A. P., & Crompton, G. K. (1990). Do large volume spacer devices reduce the systemic effects of high dose inhaled corticosteroids? Thorax. https://doi.org/10.1136/thx.45.10.736

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.