Do large volume spacer devices reduce the systemic effects of high dose inhaled corticosteroids?
Open accessThe DOI matches its Crossref record.
Abstract
When used in high doses, inhaled corticosteroids may cause suppression of the hypothalamo-pituitary-adrenal axis. The influence of the mode of drug inhalation on the degree of this suppression is not clear. Hypothalamo-pituitary-adrenal function was assessed by measurement of 0900 h serum cortisol concentrations, a short tetracosactrin test, and 24 hour urine free cortisol excretion in 48 adults with asthma taking 1500-2500 micrograms beclomethasone dipropionate daily via a metered dose aerosol. Twelve patients had hypothalamo-pituitary-adrenal suppression, as judged by subnormal results from at least two of the three tests or (in one patient) by an abnormal insulin stress test response. These patients then changed to inhaling the same dose of beclomethasone dipropionate through a 750 ml spacer device (Volumatic). The endocrine tests were repeated from nine days to eight weeks later in 10 patients. Comparison with initial values showed that adding the spacing device caused an increase in the median 0900 h cortisol concentration from 126 nmol/l to 398 nmol/l, in the post-tetracosactrin cortisol concentration from 402 nmol/l to 613 nmol/l and in 24 hour urine free cortisol excretion from 54 nmol to 84 nmol. The rise in serum cortisol concentration in response to tetracosactrin did not change. Evidence of persisting hypothalamo-pituitary-adrenal axis suppression was present in only four of the 10 patients; the most pronounced improvements in function tended to occur in those who had never required long term oral corticosteroids. The results from this uncontrolled study suggest that asthmatic patients taking high dose beclomethasone dipropionate may minimise adverse effects by using a large volume spacer device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
National Asthma Education and Prevention Program
VanGraafeiland, B. (2002) · The Nurse Practitioner · doi:10.1097/00006205-200206001-00003 · Cited by 1,091
Systemic Adverse Effects of Inhaled Corticosteroid Therapy: A Systematic Review and Meta-analysis
Lipworth, B. J. (1999) · Archives of Internal Medicine · doi:10.1001/archinte.159.9.941 · Cited by 918
“05 for before vs after beclomethasone therapy (n = 16) Nassif et al,106 1987 Prospective cohort; taking beclomethasone dipropionate (32); mean age, 13 y; prednisone taking alternate day (24); mean age, 10 y; asthmatic controls (20); mean age, 13 y; nonasthmatic subjects (21); mean age, 12 y Beclomethasone dipropionate…”
BackgroundInhaled Glucocorticoids for Asthma
Barnes, P. J. (1995) · New England Journal of Medicine · doi:10.1056/nejm199503303321307 · Cited by 629
Adrenal insufficiency in corticosteroids use: systematic review and meta-analysis
Broersen, L. H. A., Pereira, A. M., Jørgensen, J. O. L., & Dekkers, O. M. (2015) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2015-1218 · Cited by 456
Adverse effects of inhaled corticosteroids
Hanania, N. A., Chapman, K. R., & Kesten, S. (1995) · The American Journal of Medicine · doi:10.1016/s0002-9343(99)80404-5 · Cited by 294
Metadata
- Authors
- Brown, P. H., Blundell, G., Greening, A. P., & Crompton, G. K.
- Venue
- Thorax
- Publisher
- BMJ
- Published
- 1990-10-01
- Volume
- 45
- Issue
- 10
- Pages
- 736-739
- ISSN
- 0040-6376 (ISSN-L)
- OpenAlex
- W2150353636
- Cited by
- 110
- References
- 0
- FWCI
- 9.26
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Do large volume spacer devices reduce the systemic effects of high dose inhaled corticosteroids? https://app.cochat.ai/papers/10.1136/thx.45.10.736
- The paper
- Brown, P. H., Blundell, G., Greening, A. P., & Crompton, G. K. (1990). Do large volume spacer devices reduce the systemic effects of high dose inhaled corticosteroids? Thorax. https://doi.org/10.1136/thx.45.10.736
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.