Relation of ventilatory impairment and of chronic mucus hypersecretion to mortality from obstructive lung disease and from all causes.

Open access
Lange, P, Nyboe, J, Appleyard, M, Jensen, G, Schnohr, P·1990·Thorax

Abstract

The relation of ventilatory impairment and chronic mucus hypersecretion to death from all causes and death from obstructive lung disease (chronic bronchitis, emphysema and asthma) was studied in 13,756 men and women randomly selected from the general population of the City of Copenhagen. During the 10 year follow up 2288 subjects died. In 164 subjects obstructive lung disease was considered to be an underlying or a contributory cause of death (obstructive lung disease related death); in 73 subjects it was considered to be the underlying cause of death (obstructive lung disease death). Forced expiratory volume in one second, expressed as a percentage of the predicted value (FEV1% pred), and the presence of chronic phlegm were used to characterise ventilatory function and chronic mucus hypersecretion respectively. For mortality analysis the proportional hazards regression model of Cox was used; it included age, sex, pack years, inhalation habit, body mass index, alcohol consumption, and the presence or absence of asthma, heart disease, and diabetes mellitus as confounding factors. By comparison with subjects with an FEV1 of 80% pred or more, subjects with an FEV1 below 40% pred had increased risk of dying from all causes (relative risk (RR) = 5.0 for women, 2.7 for men), a higher risk of obstructive lung disease related death (RR = 57 for women, 34 for men), and a higher risk of obstructive lung disease death (RR = 101 for women, 77 for men). Chronic mucus hypersecretion was associated with only a slightly higher risk of death from all causes (RR = 1.1 for women, 1.3 for men). The association between chronic mucus hypersecretion and obstructive lung disease death varied with the level of ventilatory function, being weak in subjects with normal ventilatory function (for an FEV1 of 80% pred the RR was 1.2), but more pronounced in subjects with reduced ventilatory function (for an FEV1 of 40% pred the RR was 4.2). A similar though statistically non-significant trend was observed with regard to obstructive lung disease related death. This study shows that impaired lung function is very strongly related to total mortality, obstructive lung disease related mortality, and obstructive lung disease mortality and suggests that chronic mucus hypersecretion, in those with impaired ventilatory function, is also a significant risk factor for death from obstructive lung disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/thx.45.8.579

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 217

Metadata

Authors
Lange, P., Nyboe, J., Appleyard, M., Jensen, G., & Schnohr, P.
Venue
Thorax
Publisher
BMJ
Published
1990-08-01
Volume
45
Issue
8
Pages
579-585
ISSN
0040-6376 (ISSN-L)
OpenAlex
W2091361930
Cited by
217
References
1
FWCI
1.00
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Relation of ventilatory impairment and of chronic mucus hypersecretion to mortality from obstructive lung disease and from all causes. https://app.cochat.ai/papers/10.1136/thx.45.8.579
The paper
Lange, P., Nyboe, J., Appleyard, M., Jensen, G., & Schnohr, P. (1990). Relation of ventilatory impairment and of chronic mucus hypersecretion to mortality from obstructive lung disease and from all causes. Thorax. https://doi.org/10.1136/thx.45.8.579

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.