Neck circumference and other clinical features in the diagnosis of the obstructive sleep apnoea syndrome.

Open access
Davies, R J, Ali, N J, Stradling, J R·1992·Thorax

Abstract

BACKGROUND: Neck circumference has been suggested to be more predictive of obstructive sleep apnoea than general obesity, but the statistical validity of this conclusion has been questioned. Combining neck circumference with other signs and symptoms may allow the clinical diagnosis or exclusion of sleep apnoea to be made with reasonable confidence. This study examines these issues. METHODS: One hundred and fifty patients referred to a sleep clinic for investigation of sleep related breathing disorders completed a questionnaire covering daytime sleepiness, snoring, driving, and nasal disease. Body mass index and neck circumference corrected for height were measured and obstructive sleep apnoea severity was quantified as number of dips in arterial oxygen saturation (SaO2) of more than 4% per hour of polysomnography. Multiple linear regression was used retrospectively to identify independent predictors of SaO2 dip rate, and the model derived was then prospectively tested in a further 85 subjects. RESULTS: The retrospective analysis showed that the question "Do you fall asleep during the day, particularly when not busy?" was the best questionnaire predictor of variance in the SaO2 dip rate (r2 = 0.13); no other question improved this correlation. This analysis also showed that neither body mass index nor any of the questionnaire variables improved the amount of variance explained by height corrected neck circumference alone (r2 = 0.35). A statistically similar prospective analysis confirmed this relationship (r2 = 0.38). CONCLUSIONS: Prospective study of these patients referred to a sleep clinic with symptoms suggesting sleep apnoea shows that neck circumference corrected for height is more useful as a predictor of obstructive sleep apnoea than general obesity. None of the questionnaire variables examined add to its predictive power, but alone it is inadequate to avoid the need for sleep studies to diagnose this disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/thx.47.2.101

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 479

Metadata

Authors
Davies, R. J., Ali, N. J., & Stradling, J. R.
Venue
Thorax
Publisher
BMJ
Published
1992-02-01
Volume
47
Issue
2
Pages
101-105
ISSN
0040-6376 (ISSN-L)
OpenAlex
W1981691121
Cited by
479
References
0
FWCI
4.67
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Neck circumference and other clinical features in the diagnosis of the obstructive sleep apnoea syndrome. https://app.cochat.ai/papers/10.1136/thx.47.2.101
The paper
Davies, R. J., Ali, N. J., & Stradling, J. R. (1992). Neck circumference and other clinical features in the diagnosis of the obstructive sleep apnoea syndrome. Thorax. https://doi.org/10.1136/thx.47.2.101

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.