CoChat

Effect of inspiratory pressure support on exercise tolerance and breathlessness in patients with severe stable chronic obstructive pulmonary disease.

Open access
Keilty, S E, Ponte, J, Fleming, T A, Moxham, J · 1994 · Thorax
Cited by 117

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND: In patients with chronic obstructive pulmonary disease exercise tolerance is commonly limited by breathlessness. These patients have an increased ventilatory load at rest which is exacerbated during exercise. The purpose of this study was to investigate the effect of supporting ventilation by non-invasive inspiratory pressure support (IPS) during submaximal treadmill exercise in such patients to see if they would experience less breathlessness and improve their exercise capacity. METHODS: Eight men with disabling breathlessness due to chronic obstructive pulmonary disease (COPD) (mean (SD) FEV1 0.73 (0.2) 1) were studied. Patients walked on a treadmill until their sensation of breathlessness, scored at one minute intervals, reached level 5 ("severe") on the 10-point Borg scale. Studies were performed with IPS (mean airway pressure 12-15 cm H2O), continuous positive airway pressure (CPAP 6 cm H2O), and with oxygen (2 l/min via a mask) in random order on three separate days. Each of these walks was compared with a control walk using a sham circuit (breathing air via an oxygen mask at 2 l/min from an unlabelled cylinder), and with a baseline walk in which patients walked freely on the treadmill. On cessation of exercise, distance achieved and a leg fatigue score were recorded. RESULTS: No patients stopped due to leg fatigue, all stopping only when their sensation of breathlessness had reached level 5 on the Borg scale. IPS improved median walking distance by 62% compared with the control walk (sham circuit). There was no change in walking distance with either CPAP or oxygen at 2 l/min. There was no difference between the control and the baseline walks. CONCLUSIONS: Inspiratory pressure support can reduce breathlessness and increase exercise tolerance to submaximal treadmill exercise in patients with COPD. This could have implications for the rehabilitation of these severely disabled patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/thx.49.10.990

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Keilty, S. E., Ponte, J., Fleming, T. A., & Moxham, J.
Venue
Thorax
Publisher
BMJ
Published
1994-10-01
Volume
49
Issue
10
Pages
990-994
ISSN
0040-6376 (ISSN-L)
OpenAlex
W2166710486
Cited by
117
References
2
FWCI
2.43
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.