CoChat

Adequacy of prescribing nasal continuous positive airway pressure therapy for the sleep apnoea/hypopnoea syndrome on the basis of night time respiratory recording variables.

Open access
Montserrat, J M, Alarcon, A, Lloberes, P, Ballester, E, Fornas, C, Rodriguez-Roisin, R · 1995 · Thorax
Cited by 20

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The increased demand of full polysomnographic studies, not only for diagnostic purposes but also for continuous positive airway pressure (CPAP) titration, has produced long waiting lists. Simpler methods are therefore needed to avoid having to refer all patients for full polysomnography. The hypothesis that CPAP therapy for the sleep apnoea/hypopnoea syndrome (SAHS) can be performed exclusively on the basis of recording night time respiratory variables was tested. METHODS: The level of CPAP in a group of 41 patients (three women) of mean (SD) age 52 (10) years, body mass index 31.5 (4.4) kg/m2, and apnoea/hypopnoea index (AHI) 53(16) events/hour was measured. During a two week period CPAP titration was performed in a random order in two settings: (1) in the sleep laboratory using full polysomnography; and (2) in the respiratory ward using equipment which continuously recorded and displayed pulse oximetry, airflow, chest and abdominal motion, and body position. The level of CPAP was increased progressively until apnoea, hypopnoea, snoring, and thoraco-abdominal paradox disappeared. RESULTS: No differences in CPAP levels (9.34(2.2) versus 9.68 (2.1) cm H2O) were found between full polysomnography and night time respiratory recordings. The accuracy of the measurement of both procedures showed good agreement. Only one patient showed a significant difference in CPAP level requirements between the two methods. CONCLUSIONS: Night time respiratory recording is sufficient to permit a reasonable choice of CPAP levels to abolish all the respiratory disturbances in most of the patients studied.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/thx.50.9.969

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 20

Metadata

Authors
Montserrat, J. M., Alarcon, A., Lloberes, P., Ballester, E., Fornas, C., & Rodriguez-Roisin, R.
Venue
Thorax
Publisher
BMJ
Published
1995-09-01
Volume
50
Issue
9
Pages
969-971
ISSN
0040-6376 (ISSN-L)
OpenAlex
W2086548777
Cited by
20
References
1
FWCI
0.63
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Adequacy of prescribing nasal continuous positive airway pressure therapy for the sleep apnoea/hypopnoea syndrome on the basis of night time respiratory recording variables. https://app.cochat.ai/papers/10.1136/thx.50.9.969
The paper
Montserrat, J. M., Alarcon, A., Lloberes, P., Ballester, E., Fornas, C., & Rodriguez-Roisin, R. (1995). Adequacy of prescribing nasal continuous positive airway pressure therapy for the sleep apnoea/hypopnoea syndrome on the basis of night time respiratory recording variables. Thorax. https://doi.org/10.1136/thx.50.9.969

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.