Automatic nasal continuous positive airway pressure titration in the laboratory: patient outcomes
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Manual titration of nasal continuous positive airway pressure (NCPAP) treatment for obstructive sleep apnoea (OSA) is time consuming and expensive. There are now "intelligent" NCPAP machines that try to find the ideal pressure for a patient by monitoring a combination of apnoeas, hypopnoeas, inspiratory flow limitation, and snoring. Although these machines usually find similar pressures to skilled technicians, it is not clear if their use in the sleep laboratory influences subsequent acceptance by patients. This study addresses this question. METHODS: One hundred and twenty two patients undergoing a trial of NCPAP were randomly allocated to either manual or automatic (Horizon, DeVilbiss) titration of pressure during their first night on NCPAP in a hospital sleep laboratory. The primary outcome (available on 112 patients) was the acceptance of NCPAP or otherwise six weeks following the initial titration night. Baseline indicators of severity were compared between the groups, as were the pressures selected and the subsequent improvement in the sleepiness of the patients. RESULTS: The initial severity of OSA was not significantly different in the two groups and the mean (SD) NCPAP pressures were similar (manual 8.7 (2.5) cm H2O, automatic 8.2 (2.1) cm H2O). The percentage of patients successfully established on CPAP at six weeks was 64% and 73% for the manual and automatic groups, respectively; 13% and 2%, respectively, in the manual and automatic groups had given up completely (p < 0.05), and there were about equal numbers (23% versus 25%) in the two groups who were still undecided. CONCLUSIONS: The substitution of automatic NCPAP titration for manual titration during the first night of NCPAP in patients with OSA does not reduce the number accepting the treatment at six weeks and may slightly improve it. This has important cost saving potential.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Objective Measurement of Patterns of Nasal CPAP Use by Patients with Obstructive Sleep Apnea
Kribbs, N. B., Pack, A. I., Kline, L. R., Smith, P. L., Schwartz, A. R., Schubert, N. M., Redline, S., Henry, J. N., Getsy, J. E., & Dinges, D. F. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/147.4.887 · Cited by 1,339
Cited by
Malhotra, A., & White, D. P. (2002) · The Lancet · doi:10.1016/s0140-6736(02)09464-3 · Cited by 1,190
Jenkinson, C., Davies, R. J., Mullins, R., & Stradling, J. R. (1999) · The Lancet · doi:10.1016/s0140-6736(98)10532-9 · Cited by 826
Self-citationTask Force Members, Kushida, C. A., Chediak, A., Berry, R. B., Brown, L. K., Gozal, D., Iber, C., Parthasarathy, S., Quan, S. F., & Rowley, J. A. (2008) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27133 · Cited by 749
Flemons, W. W. (2002) · New England Journal of Medicine · doi:10.1056/nejmcp012849 · Cited by 362
Alternative Methods of Titrating Continuous Positive Airway Pressure: A Large Multicenter Study
Masa, J. F., Jiménez, A., Durán, J., Capote, F., Monasterio, C., Mayos, M., Terán, J., Hernández, L., Barbé, F., Maimó, A., et al. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200312-1787oc · Cited by 328
Metadata
- Authors
- Stradling, J. R., Barbour, C., Pitson, D. J., & Davies, R. J.
- Venue
- Thorax
- Publisher
- BMJ
- Published
- 1997-01-01
- Volume
- 52
- Issue
- 1
- Pages
- 72-75
- ISSN
- 0040-6376 (ISSN-L)
- OpenAlex
- W2130348431
- Cited by
- 103
- References
- 1
- FWCI
- 3.25
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.