Intelligent CPAP systems: clinical experience
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Nasal continuous positive airway pressure (CPAP) remains the treatment of choice for obstructive sleep apnoea (OSA) syndrome. It is believed to work by pneumatically splinting the upper airway.1 2 As the pressure is gradually increased the subject passes through a spectrum of gradually decreasing severity of obstruction.3 4 Frank obstructive apnoeas, hypopnoeas, and desaturation first disappear, then 2–4 cm H2O higher snoring and most respiratory arousals disappear, leaving only silent inspiratory airflow limitation associated with high respiratory work. This occurs at an average pressure of 8 cm H2O. A further increase of 2 cm H2O produces a 75% reduction in respiratory work and normal breathing. A higher pressure is required to prevent apnoeas in REM sleep and in the supine position, and the lowest pressure is required in slow wave sleep in the lateral position.5 Although nasal CPAP has no serious side effects in subjects with uncomplicated sleep apnoea syndrome, there are several minor side effects that reduce patient compliance and quality of life. These are chiefly pressure related, the most frequent being dryness, burning, and congestion of the nasal mucosa, discomfort exhaling against the pressure, chest wall discomfort, middle ear discomfort, mask and machine noise, conjunctivitis from leaks into the eyes, and air swallowing.6-11 The first goal of treatment initiation is therefore a “pressure titration” to find a pressure that makes a reasonable trade-off between increasing effectiveness at eliminating respiratory related events and avoiding unpleasant side effects.12 Current practice is to perform the titration in the laboratory with full polysomnography, gradually increasing the pressure through the spectrum described above, in all body positions and sleep stages.13 This is skilled, tedious, and expensive work. Furthermore, it is controversial whether the pressure determined in this way will still be correct in a month or a …
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sullivan, C., Berthon-Jones, M., Issa, F., & Eves, L. (1981) · The Lancet · doi:10.1016/s0140-6736(81)92140-1 · Cited by 2,731
Self-citationObstructive apneas during sleep in patients with seasonal allergic rhinitis.
(1982) · PubMed · doi:10.1164/arrd.1982.126.4.625 · Cited by 277
Sleep apnea and body position during sleep
George, C. F., Millar, T. W., & Kryger, M. H. (1988) · Sleep · doi:10.1093/sleep/11.1.90 · Cited by 136
Cited by
Sleep apnea: a review of diagnostic sensors, algorithms, and therapies
Shokoueinejad, M., Fernandez, C., Carroll, E., Wang, F., Levin, J., Rusk, S., Glattard, N., Mulchrone, A., Zhang, X., Xie, A., et al. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa6ec6 · Cited by 64
“Several studies have been hypothesized that adjustable lower pressure with APAP could increase acceptance and adherence with chronic positive pressure treatment (Teschler and Berthon-Jones 1998, Berthon-Jones et al 1996, Berry et al 2002, Berry and Sriram 2014).”
BackgroundPreference for fixed or automatic CPAP in patients with obstructive sleep apnea syndrome
MARRONE, O. (2004) · Sleep Medicine · doi:10.1016/j.sleep.2003.09.011 · Cited by 41
“This may lead to improved compliance, as the lower pressure could be easier to apply and to tolerate; high CPAP pressure levels may also be more commonly associated with side effects [3,4].”
BackgroundEffects of fixed compared to automatic CPAP on sleep in Obstructive Sleep Apnoea Syndrome
Resta, O., Carratù, P., Depalo, A., Giliberti, T., Ardito, M., Marrone, O., & Insalaco, G. (2004) · Monaldi Archives for Chest Disease · doi:10.4081/monaldi.2004.694 · Cited by 23
“Automatic CPAP ventilators administer a mean level of positive pressure during one night lower than fixed level CPAP machines [6, 7]. This could lead to an improvement in compliance to treatment, as a lower pressure could be easier to apply and to tolerate, and high CPAP levels may be associated with more common side…”
Background
Metadata
- Authors
- Teschler, H., & Berthon-Jones, M.
- Venue
- Thorax
- Publisher
- BMJ
- Published
- 1998-10-01
- Volume
- 53
- Issue
- Supplement 3
- Pages
- S49-S52
- ISSN
- 0040-6376 (ISSN-L)
- OpenAlex
- W2032882051
- Cited by
- 49
- References
- 3
- FWCI
- 1.81
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intelligent CPAP systems: clinical experience. https://app.cochat.ai/papers/10.1136/thx.53.2008.s49
- The paper
- Teschler, H., & Berthon-Jones, M. (1998). Intelligent CPAP systems: clinical experience. Thorax. https://doi.org/10.1136/thx.53.2008.s49
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.