CoChat

Intelligent CPAP systems: clinical experience

Open access
Teschler, H, Berthon-Jones, M · 1998 · Thorax
Cited by 49

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Nasal continuous positive airway pressure (CPAP) remains the treatment of choice for obstructive sleep apnoea (OSA) syndrome. It is believed to work by pneumatically splinting the upper airway.1 2 As the pressure is gradually increased the subject passes through a spectrum of gradually decreasing severity of obstruction.3 4 Frank obstructive apnoeas, hypopnoeas, and desaturation first disappear, then 2–4 cm H2O higher snoring and most respiratory arousals disappear, leaving only silent inspiratory airflow limitation associated with high respiratory work. This occurs at an average pressure of 8 cm H2O. A further increase of 2 cm H2O produces a 75% reduction in respiratory work and normal breathing. A higher pressure is required to prevent apnoeas in REM sleep and in the supine position, and the lowest pressure is required in slow wave sleep in the lateral position.5 Although nasal CPAP has no serious side effects in subjects with uncomplicated sleep apnoea syndrome, there are several minor side effects that reduce patient compliance and quality of life. These are chiefly pressure related, the most frequent being dryness, burning, and congestion of the nasal mucosa, discomfort exhaling against the pressure, chest wall discomfort, middle ear discomfort, mask and machine noise, conjunctivitis from leaks into the eyes, and air swallowing.6-11 The first goal of treatment initiation is therefore a “pressure titration” to find a pressure that makes a reasonable trade-off between increasing effectiveness at eliminating respiratory related events and avoiding unpleasant side effects.12 Current practice is to perform the titration in the laboratory with full polysomnography, gradually increasing the pressure through the spectrum described above, in all body positions and sleep stages.13 This is skilled, tedious, and expensive work. Furthermore, it is controversial whether the pressure determined in this way will still be correct in a month or a …

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/thx.53.2008.s49

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Teschler, H., & Berthon-Jones, M.
Venue
Thorax
Publisher
BMJ
Published
1998-10-01
Volume
53
Issue
Supplement 3
Pages
S49-S52
ISSN
0040-6376 (ISSN-L)
OpenAlex
W2032882051
Cited by
49
References
3
FWCI
1.81
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.