CoChat

Nocturnal oximetry for the diagnosis of the sleep apnoea hypopnoea syndrome: a method to reduce the number of polysomnographies?

Open access
Chiner, E., Signes-Costa, J., Arriero, J. M., Marco, J., Fuentes, I., Sergado, A. · 1999 · Thorax
Cited by 157

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Polysomnography (PSG) is currently the "gold standard" for the diagnosis of the sleep apnoea hypopnoea syndrome (SAHS). Nocturnal oximetry (NO) has been used with contradictory results. A prospective study was performed to determine the accuracy of NO as a diagnostic tool and to evaluate the reduction in the number of PSGs if the diagnosis of SAHS had been established by this method. METHODS: Two hundred and seventy five patients with a clinical suspicion of SAHS were admitted to undergo, in the same night, full PSG and NO. Desaturation was defined as a fall in the haemoglobin saturation level (SaO(2)) to lower than 4% from the baseline level and an oxygen desaturation index per hour (ODI) was obtained in each patient with three cut off points: >/= 5 (ODI-5), >/= 10 (ODI-10), and >/= 15 (ODI-15). RESULTS: SAHS was diagnosed in 216 patients (194 men). After withdrawing patients with abnormal lung function (forced expiratory volume in one second (FEV(1)) lower than 80% predicted), sensitivity (SE), specificity (SP), positive and negative predictive values (PPV and NPV) of NO were: ODI-5 (80%, 89%, 97%, 48%); ODI-10 (71%, 93%, 97%, 42%); ODI-15 (63%, 96%, 99%, 38%). The accuracy for each ODI was 0.81, 0.75, and 0.70, respectively. If NO had been considered as a diagnostic tool and PSG had been performed only in patients with a negative NO (false negative and true negative) and those with a positive NO and abnormal pulmonary function tests, 135/275 (ODI-5), 156/275 (ODI-10), and 170/275 (ODI-15) PSGs would have been performed, a reduction of 140, 119, and 105, respectively. CONCLUSION: Nocturnal oximetry in patients with suspected SAHS and normal spirometric values permits the institution of therapeutic measures in most patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/thx.54.11.968

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 157

Metadata

Authors
Chiner, E., Signes-Costa, J., Arriero, J. M., Marco, J., Fuentes, I., & Sergado, A.
Venue
Thorax
Publisher
BMJ
Published
1999-11-01
Volume
54
Issue
11
Pages
968-971
ISSN
0040-6376 (ISSN-L)
OpenAlex
W2109846048
Cited by
157
References
1
FWCI
2.94
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.