Two months follow up of auto-CPAP treatment in patients with obstructive sleep apnoea
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Continuous positive airway pressure (CPAP) with fixed mask pressure is the current standard treatment for obstructive sleep apnoea (OSA). Auto-CPAP devices apply at any time the minimally required pressure to normalise breathing and may improve patient comfort and compliance. We present an open descriptive study of auto-CPAP treatment at home in patients previously managed with conventional CPAP. METHODS: Fifteen patients with obstructive sleep apnoea (OSA), previously treated for at least one year with standard CPAP, were followed prospectively for a two month period on auto-CPAP. Outcome measures were both subjective evaluation by the patients and objective (polysomnographic) data obtained at one and two months of follow up. RESULTS: The Epworth sleepiness score did not change significantly between baseline and follow up after one and two months and no systematic changes in CPAP related side effects were reported. Compared with the baseline polysomnographic values without treatment, a significant improvement in both respiratory and sleep parameters was observed during auto-CPAP. These results were not significantly different from those obtained with standard CPAP. A significant correlation was found between the effective CPAP pressure (Peff) and the amount of time spent below Peff during auto-CPAP treatment (r = 0.6, p = 0.01). CONCLUSION: Long term auto-CPAP treatment in these patients with severe OSA appears to provide comparable efficacy to that of standard CPAP treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Objective Measurement of Patterns of Nasal CPAP Use by Patients with Obstructive Sleep Apnea
Kribbs, N. B., Pack, A. I., Kline, L. R., Smith, P. L., Schwartz, A. R., Schubert, N. M., Redline, S., Henry, J. N., Getsy, J. E., & Dinges, D. F. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/147.4.887 · Cited by 1,339
Cited by
Improving CPAP use by patients with the sleep apnoea/hypopnoea syndrome (SAHS)
Engleman, H. M., & Wild, M. R. (2003) · Sleep Medicine Reviews · doi:10.1053/smrv.2001.0197 · Cited by 473
Smith, I., & Lasserson, T. J. (2009) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003531.pub3 · Cited by 151
Autoadjusting CPAP Therapy Based on Impedance Efficacy, Compliance and Acceptance
RANDERATH, W. J., SCHRAEDER, O., GALETKE, W., FELDMEYER, F., & RÜHLE, K.-H. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.3.2006168 · Cited by 143
“In an open study involving patients pretreated with constant CPAP, Boudewyns and colleagues ( 22 ) discovered a significant improvement in the polysomnographic data with an autoadjusting CPAP system, as had been seen earlier with constant CPAP.”
BackgroundHudgel, D. W., & Fung, C. (2000) · Sleep · doi:10.1093/sleep/23.5.1g · Cited by 112
Pressure-Relief Continuous Positive Airway Pressure vs Constant Continuous Positive Airway Pressure
Nilius, G., Happel, A., Domanski, U., & Ruhle, K.-H. (2006) · Chest · doi:10.1378/chest.130.4.1018 · Cited by 99
Metadata
- Authors
- Boudewyns, A., Grillier-Lanoir, V, Willemen, M. J., De Cock, W. A., Van de Heyning, P. H., & De Backer, W. A.
- Venue
- Thorax
- Publisher
- BMJ
- Published
- 1999-02-01
- Volume
- 54
- Issue
- 2
- Pages
- 147-149
- ISSN
- 0040-6376 (ISSN-L)
- OpenAlex
- W2161478729
- Cited by
- 32
- References
- 1
- FWCI
- 1.21
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.