Normal Standards for Lung Volumes, Intrapulmonary Gas-mixing, and Maximum Breathing Capacity
Open accessAbstract
An objective assessment of respiratory function is important in the diagnosis and management of patients complaining of dyspnoea or suffering from disease involving the lungs.There are four main subdivisions, excluding blood composition, of the respiratory gas exchange process (ventilatory, dis- tributive, diffusional, and circu!atory), which are disturbed in various proportions in different diseases; therefore no single test of respiratory function can be adequate in all cases (Comroe, 1951 ; Gilson and Oldham, 1952).The ventilatory and distributive (intrapulmonary gas mixing) aspects of respiratory efficiency are commonly studied by measuring the total lung capacity (T.L.C.) and its subdivisions, the maximum breath- ing capacity (M.B.C.), the timed vital capacity (T.V.C.), and some form of "mixing efficiency" test.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Meneely, G. R., & Kaltreider, N. L. (1949) · Journal of Clinical Investigation · doi:10.1172/jci102041 · Cited by 424
Cournand, A., Baldwin, E. D., Darling, R. C., & Richards, D. W. (1941) · Journal of Clinical Investigation · doi:10.1172/jci101261 · Cited by 185
Bernstein, L., D'Silva, J. L., & Mendel, D. (1952) · Thorax · doi:10.1136/thx.7.3.255 · Cited by 174
Darling, R. C., Cournand, A. F., Richards, D. W., & Domanski, B. (1944) · Journal of Clinical Investigation · doi:10.1172/jci101473 · Cited by 99
Basal metabolism in health and disease
(1927) · The American Journal of Surgery · doi:10.1016/s0002-9610(27)91037-x · Cited by 24
Cited by
Optimum End-Expiratory Airway Pressure in Patients with Acute Pulmonary Failure
Suter, P. M., Fairley, H. B., & Isenberg, M. D. (1975) · New England Journal of Medicine · doi:10.1056/nejm197502062920604 · Cited by 1,295
The veterans administration-army cooperative study of pulmonary function
Kory, R. C., Callahan, R., Boren, H. G., & Syner, J. C. (1961) · The American Journal of Medicine · doi:10.1016/0002-9343(61)90096-1 · Cited by 792
Natural History and Treated Course of Usual and Desquamative Interstitial Pneumonia
Carrington, C. B., Gaensler, E. A., Coutu, R. E., FitzGerald, M. X., & Gupta, R. G. (1978) · New England Journal of Medicine · doi:10.1056/nejm197804132981501 · Cited by 791
Berglund, E., Birath, G., Bjure, J., Grimby, G., Kjellmer, I., Sandqvist, L., & Söderholm, B. (1963) · Acta Medica Scandinavica · doi:10.1111/j.0954-6820.1963.tb16520.x · Cited by 642
Grimby, G., & Sóderholm, B. (1963) · Acta Medica Scandinavica · doi:10.1111/j.0954-6820.1963.tb16523.x · Cited by 474
Metadata
- Authors
- Needham, C. D., Rogan, M. C., & McDonald, I.
- Venue
- Thorax
- Publisher
- BMJ
- Published
- 1954-12-01
- Volume
- 9
- Issue
- 4
- Pages
- 313-325
- ISSN
- 0040-6376 (ISSN-L)
- OpenAlex
- W2036773163
- Cited by
- 298
- References
- 5
- FWCI
- 8.56
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.