Flavourings significantly affect inhalation toxicity of aerosol generated from electronic nicotine delivery systems (ENDS)
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
BACKGROUND: E-cigarettes or electronic nicotine delivery systems (ENDS) are designed to deliver nicotine-containing aerosol via inhalation. Little is known about the health effects of flavoured ENDS aerosol when inhaled. METHODS: Aerosol from ENDS was generated using a smoking machine. Various types of ENDS devices or a tank system prefilled with liquids of different flavours, nicotine carrier, variable nicotine concentrations and with modified battery output voltage were tested. A convenience sample of commercial fluids with flavour names of tobacco, piña colada, menthol, coffee and strawberry were used. Flavouring chemicals were identified using gas chromatography/mass spectrometry. H292 human bronchial epithelial cells were directly exposed to 55 puffs of freshly generated ENDS aerosol, tobacco smoke or air (controls) using an air-liquid interface system and the Health Canada intense smoking protocol. The following in vitro toxicological effects were assessed: (1) cell viability, (2) metabolic activity and (3) release of inflammatory mediators (cytokines). RESULTS: Exposure to ENDS aerosol resulted in decreased metabolic activity and cell viability and increased release of interleukin (IL)-1β, IL-6, IL-10, CXCL1, CXCL2 and CXCL10 compared to air controls. Cell viability and metabolic activity were more adversely affected by conventional cigarettes than most tested ENDS products. Product type, battery output voltage and flavours significantly affected toxicity of ENDS aerosol, with a strawberry-flavoured product being the most cytotoxic. CONCLUSIONS: Our data suggest that characteristics of ENDS products, including flavours, may induce inhalation toxicity. Therefore, ENDS users should use the products with caution until more comprehensive studies are performed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Levels of selected carcinogens and toxicants in vapour from electronic cigarettes
Goniewicz, M. L., Knysak, J., Gawron, M., Kosmider, L., Sobczak, A., Kurek, J., Prokopowicz, A., Jablonska-Czapla, M., Rosik-Dulewska, C., Havel, C., et al. (2014) · Tobacco Control · doi:10.1136/tobaccocontrol-2012-050859 · Cited by 1,705
Self-citationE-Cigarettes: A Scientific Review
Grana, R., Benowitz, N., & Glantz, S. A. (2014) · Circulation · doi:10.1161/circulationaha.114.007667 · Cited by 1,194
Lerner, C. A., Sundar, I. K., Yao, H., Gerloff, J., Ossip, D. J., McIntosh, S., Robinson, R., & Rahman, I. (2015) · PLOS ONE · doi:10.1371/journal.pone.0116732 · Cited by 666
Nicotine Levels in Electronic Cigarettes
Goniewicz, M. L., Kuma, T., Gawron, M., Knysak, J., & Kosmider, L. (2013) · Nicotine & Tobacco Research · doi:10.1093/ntr/nts103 · Cited by 590 · cited 1×
“24 25 To measure the effects of ENDS voltage on cellular toxicity, aerosols were generated from an eGo tank system fi lled with PG-only solution containing tobacco fl avour and 24 mg/mL of nicotine that was set to 3.3, 4.0 or 4.8 V.”
MethodInfluentialSelf-citationFlavour chemicals in electronic cigarette fluids
Tierney, P. A., Karpinski, C. D., Brown, J. E., Luo, W., & Pankow, J. F. (2016) · Tobacco Control · doi:10.1136/tobaccocontrol-2014-052175 · Cited by 365
Chemical hazards present in liquids and vapors of electronic cigarettes
Hutzler, C., Paschke, M., Kruschinski, S., Henkler, F., Hahn, J., & Luch, A. (2014) · Archives of Toxicology · doi:10.1007/s00204-014-1294-7 · Cited by 348 · cited 1×
“5 6 8 Hutzler et al 9 analysed 28 ENDS liquids by gas chromatography/mass spectrometry (GC/MS) and identi fi ed 141 different fl avouring chemicals among them.”
BackgroundCorey, C. G., Wang, B., Johnson, S. E., Apelberg, B. J., Husten, C. G., King, B. A., McAfee, T. A., Bunnell, R. E., Arrazola, R. A., & Dube, S. R. (2013) · Cited by 325
Identification of toxicants in cinnamon-flavored electronic cigarette refill fluids
Behar, R. Z., Davis, B., Wang, Y., Bahl, V., Lin, S., & Talbot, P. (2014) · Toxicology in Vitro · doi:10.1016/j.tiv.2013.10.006 · Cited by 248
(2013) · PubMed Central · Cited by 247
Farsalinos, K., Romagna, G., Allifranchini, E., Ripamonti, E., Bocchietto, E., Todeschi, S., Tsiapras, D., Kyrzopoulos, S., & Voudris, V. (2013) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph10105146 · Cited by 223 · cited 1×
“10 Farsalinos et al 11 evaluated sweet-fl avoured e-liquids for the presence of diace-tyl and acetyl propionyl, which are chemicals approved for food use but are associated with respiratory disease when inhaled.”
Background
Cited by
Pulmonary toxicity of e-cigarettes
Chun, L. F., Moazed, F., Calfee, C. S., Matthay, M. A., & Gotts, J. E. (2017) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.00071.2017 · Cited by 311
Pro-inflammatory effects of e-cigarette vapour condensate on human alveolar macrophages
Scott, A., Lugg, S. T., Aldridge, K., Lewis, K. E., Bowden, A., Mahida, R. Y., Grudzinska, F. S., Dosanjh, D., Parekh, D., Foronjy, R., et al. (2018) · Thorax · doi:10.1136/thoraxjnl-2018-211663 · Cited by 274
Muthumalage, T., Prinz, M., Ansah, K. O., Gerloff, J., Sundar, I. K., & Rahman, I. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2017.01130 · Cited by 272
E-cigarettes: Impact of E-Liquid Components and Device Characteristics on Nicotine Exposure
DeVito, E. E., & Krishnan-Sarin, S. (2018) · Current Neuropharmacology · doi:10.2174/1570159x15666171016164430 · Cited by 248
“, reduced metabolic activity, cytokine release): reduced metabolic activity was observed following exposure to vapors from 50PG/50VG and VG only, but not PG only, while cytokine release was increased following exposure to PG only [91].”
BackgroundZare, S., Nemati, M., & Zheng, Y. (2018) · PLOS ONE · doi:10.1371/journal.pone.0194145 · Cited by 240
High exposure to nicotine among adolescents who use Juul and other vape pod systems (‘pods’)
Goniewicz, M. L., Boykan, R., Messina, C. R., Eliscu, A., & Tolentino, J. (2019) · Tobacco Control · doi:10.1136/tobaccocontrol-2018-054565 · Cited by 231
Self-citationWills, T. A., Soneji, S. S., Choi, K., Jaspers, I., & Tam, E. K. (2021) · European Respiratory Journal · doi:10.1183/13993003.01815-2019 · Cited by 218
Omaiye, E. E., McWhirter, K. J., Luo, W., Pankow, J. F., & Talbot, P. (2019) · Chemical Research in Toxicology · doi:10.1021/acs.chemrestox.8b00381 · Cited by 217
Rose, J. J., Krishnan-Sarin, S., Exil, V. J., Hamburg, N. M., Fetterman, J. L., Ichinose, F., Perez-Pinzon, M. A., Rezk-Hanna, M., Williamson, E., & on behalf of the American Heart Association Council on Cardiopulmonary, C. C. (2023) · Circulation · doi:10.1161/cir.0000000000001160 · Cited by 215
Gerloff, J., Sundar, I. K., Freter, R., Sekera, E. R., Friedman, A. E., Robinson, R., Pagano, T., & Rahman, I. (2017) · Applied In Vitro Toxicology · doi:10.1089/aivt.2016.0030 · Cited by 213
“Recently, it has been shown that ENDS aerosol containing flavorings on exposure in human bronchial epithelial cells caused decreased metabolic activity and viability, and increased release of cytokines, such as IL-1b, IL-6, IL-10, CXCL1, CXCL2, and CXCL10.”
BackgroundE-cigarettes induce toxicological effects that can raise the cancer risk
Canistro, D., Vivarelli, F., Cirillo, S., Babot Marquillas, C., Buschini, A., Lazzaretti, M., Marchi, L., Cardenia, V., Rodriguez-Estrada, M. T., Lodovici, M., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-02317-8 · Cited by 193
Ganapathy, V., Manyanga, J., Brame, L., McGuire, D., Sadhasivam, B., Floyd, E., Rubenstein, D. A., Ramachandran, I., Wagener, T., & Queimado, L. (2017) · PLOS ONE · doi:10.1371/journal.pone.0177780 · Cited by 178
“Another variable to consider, is the fact that toxicant yield varies with EC brand, product model, e-liquid flavor, e-liquid solvent, and device power [19, 21, 23, 84, 85] so it is not possible to directly compare our study to others using different ECs or e-liquids.”
BackgroundAnalytical and toxicological evaluation of flavor chemicals in electronic cigarette refill fluids
Behar, R. Z., Luo, W., McWhirter, K. J., Pankow, J. F., & Talbot, P. (2018) · Scientific Reports · doi:10.1038/s41598-018-25575-6 · Cited by 175
Kaur, G., Muthumalage, T., & Rahman, I. (2018) · Toxicology Letters · doi:10.1016/j.toxlet.2018.02.025 · Cited by 159
Voos, N., Smith, D., Kaiser, L., Mahoney, M. C., Bradizza, C. M., Kozlowski, L. T., Benowitz, N. L., O’Connor, R. J., & Goniewicz, M. L. (2020) · Psychopharmacology · doi:10.1007/s00213-019-05386-x · Cited by 51
Self-citation
Metadata
- Authors
- Leigh, N. J., Lawton, R. I., Hershberger, P. A., & Goniewicz, M. L.
- Venue
- Tobacco Control
- Publisher
- BMJ
- Published
- 2016-09-15
- Volume
- 25
- Issue
- Suppl 2
- Pages
- ii81-ii87
- ISSN
- 0964-4563 (ISSN-L)
- 1468-3318
- OpenAlex
- W2520706757
- Cited by
- 240
- References
- 25
- FWCI
- 19.39
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.