The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
IQOS: examination of Philip Morris International’s claim of reduced exposure
Open accessAbstract
Background: New electronic heated tobacco products are being introduced in the global market and are gaining popularity. In 2016, Philip Morris International, Inc. (PMI) submitted a modified risk tobacco product (MRTP) application to the Food and Drug Administration (FDA) to market IQOS in the USA with claims of reduced exposure and reduced risk. Methods: We examined PMI’s MRTP application, specifically sections on aerosol chemistry and human exposure assessment, to assess the validity of PMI’s claims of reduced exposure and risk. Findings: PMI reported levels for only 40 of 93 harmful and potentially harmful constituents (HPHCs) on FDA’s HPHC list in IQOS mainstream aerosol. All substances in PMI’s list of 58 constituents (PMI-58) were lower in IQOS emissions compared with mainstream smoke of 3R4F reference cigarettes. However, levels of 56 other constituents, which are not included in the PMI-58 list or FDA’s list of HPHCs, were higher in IQOS emissions; 22 were >200% higher and seven were >1000% higher than in 3R4F reference cigarette smoke. PMI’s studies also show significantly lower systemic exposure to some HPHCs from use of IQOS compared with smoking combustible cigarettes. Conclusion: PMI’s data appear to support PMI’s claim that IQOS reduces exposure to HPHCs. However, PMI’s data also show significantly higher levels of several substances that are not recognised as HPHCs by the FDA in IQOS emissions compared with combustible cigarette smoke. The impact of these substances on the overall toxicity or harm of IQOS is not known.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
E-Cigarettes: A Scientific Review
Grana, R., Benowitz, N., & Glantz, S. A. (2014) · Circulation · doi:10.1161/circulationaha.114.007667 · Cited by 1,194
Self-citationHidden formaldehyde in e-cigarette aerosols
Jensen, R. P., Luo, W., Pankow, J. F., Strongin, R. M., & Peyton, D. H. (2015) · New England Journal of Medicine · doi:10.1056/nejmc1413069 · Cited by 605
Cited by
2018 ACC Expert Consensus Decision Pathway on Tobacco Cessation Treatment
Barua, R. S., Rigotti, N. A., Benowitz, N. L., Cummings, K. M., Jazayeri, M.-A., Morris, P. B., Ratchford, E. V., Sarna, L., Stecker, E. C., & Wiggins, B. S. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.027 · Cited by 353
Self-citation
Metadata
- Authors
- St.Helen, G., Jacob III, P., Nardone, N., & Benowitz, N. L.
- Venue
- Tobacco Control
- Publisher
- BMJ
- Published
- 2018-08-29
- Volume
- 27
- Issue
- Suppl 1
- Pages
- s30-s36
- ISSN
- 0964-4563 (ISSN-L)
- 1468-3318
- OpenAlex
- W2889384664
- Cited by
- 207
- References
- 2
- FWCI
- 14.40
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: IQOS: examination of Philip Morris International’s claim of reduced exposure. https://app.cochat.ai/papers/10.1136/tobaccocontrol-2018-054321
- The paper
- St.Helen, G., Jacob III, P., Nardone, N., & Benowitz, N. L. (2018). IQOS: examination of Philip Morris International’s claim of reduced exposure. Tobacco Control. https://doi.org/10.1136/tobaccocontrol-2018-054321
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.