CoChat

Modeling Impulsive Injections of Insulin: Towards Artificial Pancreas

Huang, Mingzhan, Li, Jiaxu, Song, Xinyu, Guo, Hongjian · 2012 · SIAM Journal on Applied Mathematics

The DOI matches its Crossref record; 26 of the 28 references it cites were found in a registry or an index, and 2 are not checked yet.

Abstract

We propose two novel mathematical models with impulsive injection of insulin or its analogues for type 1 and type 2 diabetes mellitus. One model incorporates the periodic impulsive injection of insulin. We analytically show the existence and uniqueness of a positive globally asymptotically stable periodic solution for type 1 diabetes, which implies that the perturbation caused by insulin injection will not disturb homeostasis but amend the glucose from a pathological level toward a healthier level. We also show that the system is uniformly permanent for type 2 diabetes, that is, the glucose concentration level is uniformly bounded above and below. The other model determines the insulin injection by closely monitoring the glucose level when it reaches or passes a predefined but adjustable threshold value. We analytically prove the existence and stability of the order one periodic solution, which ensures that the perturbation by the injection in such an automated way can keep the blood glucose concentration under control. Our numerical analysis confirms and further enhances the usefulness and robustness of our models. The first model has clinical implications in that the glucose level of a diabetic can be controlled within a desired level by adjusting the values of two model parameters, injection period and injection dose. A method for choosing these two parameters is described. The second model is, to the best of our knowledge, the first attempt to conquer some critical issues in the design of an artificial pancreas with closed-loop approach. For the former case, our numerical analysis reveals that a regime with a smaller insulin dose and more frequent deliveries is more efficient and effective, but surprisingly, for the latter case, a larger dose is more effective. This can be significant in the design and development of the insulin pump and artificial pancreas.

Overview

Integrity signals

Registry

Crossref · 10.1137/110860306

Cites

26 of 28 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 28 references

Research works printed but not linked: 5

  1. Chen L. S., 2011, J. Beihua University, 12, 1
  2. L. Perko, Differential Equations and Dynamical Systems , 3rd ed., Springer, Berlin, 2006.
  3. Roszler J., 2002, Diabetes Forecast, 55, 37
  4. Spollett G. R., 2005, Doc News, 2
  5. Sturis J., 1991, Amer. J. Physiol., 260, E801

Cited by

Items 101–119 of 119

Metadata

Authors
Huang, M., Li, J., Song, X., & Guo, H.
Venue
SIAM Journal on Applied Mathematics
Published
2012-01
Volume
72
Issue
5
Pages
1524-1548
ISSN
  • 0036-1399 (ISSN-L)
  • 1095-712X
OpenAlex
W2012470375
Cited by
119
References
27
Citations by year
2026: 4 · 2025: 4 · 2024: 13 · 2023: 7 · 2022: 11 · 2021: 7 · 2020: 9 · 2019: 8 · 2018: 11 · 2017: 11 · 2016: 10 · 2015: 12 · 2014: 8 · 2013: 4
FWCI
6.15
Type
journal article
Language
en
Open access
closed
Locations
SIAM Journal on Applied Mathematics (publishedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Physical Sciences › Mathematics › Applied Mathematics › Mathematical and Theoretical Epidemiology and Ecology Models
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Pancreatic function and diabetes
Keywords
insulin, artificial pancreas, type 1 diabetes, type 2 diabetes, glucose homeostasis, global asymptotic stability, insulin pump

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.