An Artificial Endocrine Pancreas

Albisser, A M, Leibel, B S, Ewart, T G, Davidovac, Z, Botz, C K, Zingg, W·1974·Diabetes

Abstract

In order to regulate the blood sugar in the intact depancreatized dog as precisely as that accomplished by its normal pancreas, specific equipment has been devised to deliver insulin or glucose continuously and establish normoglycemia both in the fasting and glucose-loaded states. A minicomputer was programmed to respond to the constantly monitored whole blood glucose by injecting appropriate insulin or glucose intravenously to maintain or restore the normal blood sugar. Standardized glucose challenges consisting of uniform infusions of 10 mg. glucose per kg. min. for sixty minutes were applied to assess the performance of the artificial pancreas. Direct control which relates insulin dosage to the level of the circulating blood sugar results in a response to the challenge resembling mild maturity-onset diabetes both in the abnormally high blood sugar response to glucose loading and in the large amount of insulin required to effect a return to normoglycemia. In contrast, control based on projected (predicted) values of blood sugar not only prevents the abnormal rise but consumes in some cases only 10 per cent of the insulin used for the same glucose load. The performance of the system parallels that of the normal pancreas and lends support to the hypothesis that biphasic insulin responses to glucose challenges are essential for the economy of insulin and the precision of regulation seen in healthy subjects.

Integrity signals

Registry

Crossref · 10.2337/diab.23.5.389

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The first bedside computer-controlled closed-loop system, the Biostator, was invented by Miles Laboratory in 1974.

    “The first bedside computer-controlled closed-loop system, the Biostator, was invented by Miles Laboratory (Elkhart IN) in 1974 (ref. 124).”

Cited by

Sorted by citations

Authors
Albisser, A. M., Leibel, B. S., Ewart, T. G., Davidovac, Z., Botz, C. K., & Zingg, W.
Affiliations
University of Toronto (CA)
Venue
Diabetes
Published
1974-05-01
Volume
23
Issue
5
Pages
389-396
ISSN
  • 0012-1797 (ISSN-L)
  • 1939-327X
OpenAlex
W2134653585
Cited by
379
References
0
Citations by year
2026: 3 · 2025: 8 · 2024: 6 · 2023: 9 · 2022: 7 · 2021: 3 · 2020: 8 · 2019: 10 · 2018: 11 · 2017: 13 · 2016: 13 · 2015: 6 · 2014: 17 · 2013: 8 · 2012: 14
FWCI
9.68
Type
journal article
Language
en
Open access
closed
Locations
  • Diabetes (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Surgery › Pancreatic function and diabetes
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
Keywords
artificial pancreas, continuous insulin infusion, glucose infusion, depancreatized dogs, normoglycemia, type 1 diabetes, insulin dose, blood glucose monitoring, minicomputer control
MeSH terms
Analog-Digital Conversion, Animals, Artificial Organs, Blood Glucose, Computers, Diabetes Mellitus, Dogs, Glucose, Glucose Tolerance Test, Homeostasis, Infusions, Parenteral, Insulin, Islets of Langerhans, Lipase, Mathematics, Pancreatectomy, Pancreatin, Research Design, Insulin, Long-Acting

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review