The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
ADSORPTION EQUILIBRIA OF HYDROGEN, DEUTERIUM, AND THEIR MIXTURES. PART I
Abstract
Adsorption isotherms of hydrogen and deuterium have been measured at temperatures of 75–90 °K and pressures up to 760 mm Hg on the following six adsorbents: charcoal (2), silica gel, and Linde molecular sieves type 4A, 5A, and 13X.Deuterium was found to be adsorbed to a greater extent than hydrogen in all cases investigated, its isosteric heat of adsorption exceeding that of hydrogen by 50 to 300 cal/mole.Binary adsorption isotherms were determined on the same adsorbents in the range 10–90% D 2 at temperatures of 75 and 90 °K and a total pressure π of 750 and 200 mm Hg. The analyses were performed by the thermal conductivity method using thermistor sensing elements in a static system at atmospheric pressure. The device proved of exceptional stability, requiring no recalibrations and yielding an analytical accuracy of better than 0.02% deuterium content. The binary separation factors α were found to be constant over the concentration range investigated, with values for α varying from about 1.25 on charcoal to 2.54 on type 4A molecular sieves at 75 °K and 750 mm Hg. The results suggest that the variations in α are due mainly to differences in chemical composition of the adsorbents rather than pore size, surface area, or origin of the materials.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
According to prior studies, heavier hydrogen isotopes were more strongly adsorbed than lighter isotopes, mainly due to their larger heats of adsorption, and no remarkable influence of pore size was observed, not even in microporous adsorbents.
“According to these studies, the heavier isotopes were more strongly adsorbed than the lighter isotopes, mainly due to their larger heats of adsorption, and no remarkable influence of the pore size was observed, not even in microporous adsorbents.399,402,403”
From Zeolites in Adsorption Processes: State of the Art and Future Prospects (2022) · cites this paper as [402]
Separation-oriented adsorption studies of hydrogen isotopes on activated carbons, silicas, and zeolites have been reported since the 1930s.
“Separation-oriented adsorption studies of hydrogen isotopes on activated carbons, silicas, and zeolites have been reported since the 1930s by several authors.398−404”
From Zeolites in Adsorption Processes: State of the Art and Future Prospects (2022) · cites this paper as [402]
Citations
Cites
�ber das Auftreten des Tunneleffektes bei Ad- und Desorption der Wasserstoffisotope
Harteck, P., & Melkonian, G. A. (1950) · Die Naturwissenschaften · doi:10.1007/bf00638075 · Cited by 7
Flagged first, then by citations
Research works printed but not linked: 20
- GLUECICAUF E., 1949, Discissions 1:araday Soc., 7, 199
- MELICONIAN G. A., 1954, Z. Elektrochern., 58, 616
- EDSE R., 1940, Chem., 53, 210
- WHITE D., 1959, J. Chem. Phys., 27, 1368, 10.1063/1.1730203 · DOI · Paper page
- PETERS,R. and LOHMAR, \V. Doklady .Alcad. Naulc S.S.S.R. 57, 157 (1947).
- 1937, Chem. A, 180, 51
- GOULD A. J., 1934, J . Chern. Phys., 2, 362, 10.1063/1.1749490 · DOI · Paper page
- THOMAS C., 1959, Phys. Chern., 63, 427, 10.1021/j150573a021 · DOI
- OHROSHI S., 1958, J . Chem. Soc. Japan, 31, 770, 10.1246/bcsj.31.770 · DOI
- FARKAS,A. Orthohydrogen, parahydrogen and heavy hydrogen. The University Press, Cambridge, Eng. 1935.
- SACHSSE,13. and B A T % L E < I< Z.physik. Chem. rl, 171, 331 (1934). · DOI
- GROSS P., 1933, Mikrochemie, 17, 43, 10.1007/BF02740117 · DOI
- TRENNER N. R., 1937, Chem. Phys., 5, 382
- SANDLER, Y . C. J . Phys. dhem. 58,<58(1954). ' · DOI
- CUNNINGHALL C. M., J . rl, 11
- BURSTEIK R., 1938, Physicochim U. R. S. S., 8, 857
- 1939, TAN DER WAARDEN. Physica, 6, 49
- M. and SCHEFFER.F. E. C. Rec. tray. chim. 71. 689 (1952). · DOI
- BARRER R. M., 1959, Brit. Chern. Eng., 4, 267
- VAN CLEAVE A. B., 1935, Research, 12, 57
Cited by
Sorted by citations
Zeolites in Adsorption Processes: State of the Art and Future Prospects
Pérez-Botella, E., Valencia, S., & Rey, F. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00140 · Cited by 1,126
Metadata
- Authors
- Basmadjian, D.
- Corresponding author
- Basmadjian, D.
- Venue
- Canadian Journal of Chemistry
- Publisher
- Canadian Science Publishing
- Published
- 1960-01-01
- Volume
- 38
- Issue
- 1
- Pages
- 141-148
- ISSN
- 0008-4042 (ISSN-L)
- 1480-3291
- OpenAlex
- W1990930570
- Cited by
- 74
- References
- 1
- Citations by year
- 2025: 2 · 2022: 3 · 2020: 3 · 2019: 2 · 2018: 2 · 2017: 3 · 2016: 1 · 2014: 1 · 2013: 1
- FWCI
- 0.74
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Canadian Journal of Chemistry (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Adsorption, diffusion, and thermodynamic properties of materials
- Physical Sciences › Materials Science › Materials Chemistry › Hydrogen Storage and Materials
- Physical Sciences › Chemical Engineering › Filtration and Separation › Membrane Separation and Gas Transport
- Keywords
- hydrogen adsorption, deuterium adsorption, hydrogen-deuterium mixtures, adsorption isotherms, isosteric heat of adsorption, charcoal, silica gel, molecular sieves, cryogenic adsorption
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review