Relating flame radiation to home ignition using modeling and experimental crown fires
The DOI matches its Crossref record; 8 of the 9 references it cites were found in a registry or an index.
Abstract
Wildlandurban fire destruction depends on homes igniting and thus requires an examination of the ignition requirements. A physicaltheoretical model, based on severe case conditions and ideal heat transfer characteristics, estimated wood wall ignition occurrence from flame radiation heating and piloted ignition requirements. Crown fire experiments provided an opportunity for assessing model reliability. The crown fire experiments were specifically instrumented with wood wall sections and heat flux sensors to investigate direct flame heating leading to home ignition during wildland fires. The experimental results indicated that the flame radiation model overestimated the structure-to-flame distance that would result in wood wall ignition. Wall sections that ignited during the experimental crown fires did not sustain flaming after crown fire burnout. The experiments also revealed that the forest canopy attenuated the flame radiation as the crown fire spread within the forest plot. Ignition modeling and the associated crown fire experiments described the flame-to-structure distance scale associated with flame heating related to wall ignition.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Cohen (2004) reported that models predicted ignition of wood walls when less than 28 m from a crown fire in forested vegetation, with actual experimental crown fires finding ignition at a 10-m distance, but not 20 m or 30 m.”
From Housing arrangement and vegetation factors associated with single-family home survival in the 2018 Camp Fire, California (2021) · cites this paper as Cohen (2004)
Citations
Cites
An Introduction to Fire Dynamics
Drysdale, D. (2011) · Wiley eBooks · doi:10.1002/9781119975465 · Cited by 2,598
Preventing Disaster: Home Ignitability in the Wildland-Urban Interface
Cohen, J. D. (2000) · Journal of Forestry · doi:10.1093/jof/98.3.15 · Cited by 459 · cited 1×
“The model results indicated that the radiation heat transfer, to meet the requirements for piloted ignition, had to occur at flame-to-structure distances less than 40 m (Cohen 2000).”
BackgroundSelf-citationCrown fire behaviour in a northern jack pine black spruce forest
Stocks, B. J., Alexander, M. E., Wotton, B. M., Stefner, C. N., Flannigan, M. D., Taylor, S. W., Lavoie, N., Mason, J. A., Hartley, G. R., Maffey, M. E., et al. (2004) · Canadian Journal of Forest Research · doi:10.1139/x04-054 · Cited by 193 · cited 4×
“The International Crown Fire Modelling Experiment (Stocks et al. 2004) offered an opportunity to compare model estimates of heating and wood ignition with measured heat fluxes and the observed occurrence of ignition during actual crown fires.”
BackgroundInfluentialThe Wildland-Urban Interface: Paradise or Battleground?
Davis, J. B. (1990) · Journal of Forestry · doi:10.1093/jof/88.1.26 · Cited by 111
HEAT TRANSFER THROUGH FABRICS AS RELATED TO THERMAL INJURY*†
Stoll, A. M., & Chianta, M. A. (1971) · Transactions of the New York Academy of Sciences · doi:10.1111/j.2164-0947.1971.tb02630.x · Cited by 105
Cohen, J. D., & Butler, B. W. (1998) · Cited by 56
Self-citationStructure ignition assessment model (SIAM)
Cohen, J. D. (1995) · Cited by 38
Self-citationA site-specific approach for assessing the fire risk to structures at the wildland/urban interface
Cohen, J. D. (1991) · Cited by 17
Self-citation
Research works printed but not linked: 4
- Butler C.P., 1974, Papers, 74, 1
- Cohen J.D., 2000, J. For., 98, 15
- Davis J.B., 1990, J. For., 88, 26
- Stocks B.J., 2004, J. For. Res. 34. This issue.
Cited by
Learning to coexist with wildfire
Moritz, M. A., Batllori, E., Bradstock, R. A., Gill, A. M., Handmer, J., Hessburg, P. F., Leonard, J., McCaffrey, S., Odion, D. C., Schoennagel, T., et al. (2014) · Nature · doi:10.1038/nature13946 · Cited by 1,169
How risk management can prevent future wildfire disasters in the wildland-urban interface
Calkin, D. E., Cohen, J. D., Finney, M. A., & Thompson, M. P. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1315088111 · Cited by 529
Self-citationThe wildland–urban interface fire problem – current approaches and research needs
Mell, W. E., Manzello, S. L., Maranghides, A., Butry, D., & Rehm, R. G. (2010) · International Journal of Wildland Fire · doi:10.1071/wf07131 · Cited by 444
“Empirical studies on structure ignition from flame fronts As part of the International Crown Fire Modelling Experiment, seven experiments included mock structural walls of untreated and unpainted plywood placed 10, 20 and 30 m from the downwind edge of the wildland burn plot (Cohen 2004).”
BackgroundMethodInfluentialReinhardt, E. D., Keane, R. E., Calkin, D. E., & Cohen, J. D. (2008) · Forest Ecology and Management · doi:10.1016/j.foreco.2008.09.016 · Cited by 349
Self-citationCaton, S. E., Hakes, R. S. P., Gorham, D. J., Zhou, A., & Gollner, M. J. (2017) · Fire Technology · doi:10.1007/s10694-016-0589-z · Cited by 241
“The derived flux-time correlation identified two primary ignition criteria for wood: a minimum critical heat flux of 13 kW/m(2) and a critical heating dosage level which accumulates over time [11].”
BackgroundInfluential
Metadata
- Authors
- Cohen, J. D.
- Corresponding author
- Cohen, Jack D
- Venue
- Canadian Journal of Forest Research
- Publisher
- Canadian Science Publishing
- Published
- 2004-08-01
- Volume
- 34
- Issue
- 8
- Pages
- 1616-1626
- ISSN
- 0045-5067 (ISSN-L)
- 1208-6037
- OpenAlex
- W2063976525
- Cited by
- 167
- References
- 9
- Citations by year
- 2026: 12 · 2025: 11 · 2024: 8 · 2023: 12 · 2022: 11 · 2021: 5 · 2020: 20 · 2019: 10 · 2018: 13 · 2017: 5 · 2016: 4 · 2015: 8 · 2014: 11 · 2013: 4 · 2012: 6
- FWCI
- 12.63
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.nrcresearchpress.com/page/about/CorporateTextAndDataMining (tdm)
- Locations
- Canadian Journal of Forest Research (publishedVersion)
- Topics
- Physical Sciences › Engineering › Safety, Risk, Reliability and Quality › Fire dynamics and safety research
- Physical Sciences › Environmental Science › Global and Planetary Change › Fire effects on ecosystems
- Physical Sciences › Engineering › Computational Mechanics › Combustion and flame dynamics
- Keywords
- flame radiation, wildland-urban interface, crown fire, piloted ignition, heat flux, wildfire spread, ignition modeling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.