Rapid vertical tube rotor gradient assay for binding of 2,3,7,8-tetrachIorodibenzo-p-dioxin to the Ah receptor
The DOI matches its Crossref record.
Abstract
The Ah receptor, which regulates induction of aryl hydrocarbon hydroxylase (cytochrome P 1-450), can be assayed using [3 H]2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) as the radioligand. Sucrose density gradient (SDG) centrifligation is the most reliable method for detecting and quantitating Ah receptor; however, previous gradient assays in swinging bucket rotors (SBR) have required overnight centrifugation to achieve adequate separation of specific receptor peaks from nonspecific binding to other cytosolic components. These lengthy runs limit the number of assays which can be performed and could permit excessive dissociation of radioligand from the receptor. Thus, we tested brief (2-h) SDG centrifugation assays in a vertical tube rotor (VTR) as a possible alternative to prolonged SBR runs. Two-hour VTR runs yield gradient profiles very similar to those obtained with 16-h runs in an SBR and the calculated sedimentation coefficient (in low ionic strength buffer) is about 9.6 S for the Ah receptor assayed in either rotor. The concentration of Ah receptor in cytosols from liver, lung, kidney, and testis of C57BL/6J mice is the same by VTR analysis as when measured by SBR analysis. Thus, extensive dissociation of [3 H]TCDD from the Ah receptor does not appear to occur in cystosols from a variety of tissues even with run times up to 16 h. Assays performed by rapid VTR centrifugation appear equally valid to those obtained by overnight SBR centrifugation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Enzyme induction in the cytochrome P-450 system
Okey, A. B. (1990) · Pharmacology & Therapeutics · doi:10.1016/0163-7258(90)90030-6 · Cited by 625
Self-citationThe aryl hydrocarbon receptor: A comparative perspective
Hahn, M. E. (1998) · Comparative Biochemistry and Physiology Part C: Pharmacology, Toxicology and Endocrinology · doi:10.1016/s0742-8413(98)10028-2 · Cited by 369
Okey, A. B. (2007) · Toxicological Sciences · doi:10.1093/toxsci/kfm096 · Cited by 258
Self-citationKarchner, S. I., Franks, D. G., Kennedy, S. W., & Hahn, M. E. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0509950103 · Cited by 207
Pohjanvirta, R., Viluksela, M., Tuomisto, J. T., Unkila, M., Karasinska, J., Franc, M.-A., Holowenko, M., Giannone, J. V., Harper, P. A., Tuomisto, J., et al. (1999) · Toxicology and Applied Pharmacology · doi:10.1006/taap.1998.8565 · Cited by 105
Self-citation
Metadata
- Authors
- Tsui, H. W., & Okey, A. B.
- Venue
- Canadian Journal of Physiology and Pharmacology
- Publisher
- Canadian Science Publishing
- Published
- 1981-09-01
- Volume
- 59
- Issue
- 9
- Pages
- 927-931
- ISSN
- 0008-4212 (ISSN-L)
- 1205-7541
- OpenAlex
- W2108131387
- Cited by
- 74
- References
- 0
- FWCI
- 3.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid vertical tube rotor gradient assay for binding of 2,3,7,8-tetrachIorodibenzo-p-dioxin to the Ah receptor. https://app.cochat.ai/papers/10.1139/y81-143
- The paper
- Tsui, H. W., & Okey, A. B. (1981). Rapid vertical tube rotor gradient assay for binding of 2,3,7,8-tetrachIorodibenzo-p-dioxin to the Ah receptor. Canadian Journal of Physiology and Pharmacology. https://doi.org/10.1139/y81-143
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.