Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 166

The DOI matches its Crossref record.

Predicting submaximal oxygen consumption during treadmill running in mice

Fernando, P., Bonen, A., Hoffman-Goetz, L. · 1993 · Canadian Journal of Physiology and Pharmacology

Abstract

Treadmill exercise is the most common form of exercise used in studies involving laboratory rodents. However, oxygen consumption [Formula: see text] is not usually monitored since the measurement of this parameter is particularly difficult in small, exercising animals. The purpose of this study was to develop a regression equation for predicting submaximal [Formula: see text] in mice during treadmill running. Twenty female mice of three strains were tested, in an Oxyscan metabolic treadmill, on different days at running speeds of 10, 13, 15, 17, and 20 m/min at a 0% grade. Each mouse was placed in the treadmill chamber for a 10-min period before running commenced. Running speed was increased in 2-min intervals by 5 m/min until the assigned speed was reached. Each mouse then ran for 10 min to reach steady state, followed by another 20 min at the steady-state plateau. During this period a 30-s expired gas sample was collected every minute. Gas samples were analyzed for O 2 and CO 2, using an Oxyscan gas analyzer. Trials were conducted during the nocturnal phase of the animals' photoperiod, and running speeds were assigned randomly to minimize order effects. This approach provided highly reliable measures of oxygen consumption (r = 0.96). By using the running speeds (10–20 m/min) and the animal's body weight it was possible to predict the submaximal oxygen consumption (mL/min) during running with a high degree of accuracy (i.e., R 2 = 0.85). In an independent group of animals (n = 14) we compared the predicted [Formula: see text] with the measured [Formula: see text]. This yielded a good correlation coefficient (r = 0.79) and a low prediction error (+2.4 ± 2.9%). This study demonstrated that it is possible to predict the submaximal oxygen consumption of laboratory mice during exercise, with an acceptable prediction error, from relatively simple measures (running speed and body weight). In addition, it was also possible to predict accurately the relative intensity of exercise [Formula: see text] using the animal's running speed on the treadmill (r = 0.999).Key words: submaximal [Formula: see text], treadmill exercise, regression equation, rodents.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1139/y93-128

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 166

Metadata

Authors
Fernando, P., Bonen, A., & Hoffman-Goetz, L.
Venue
Canadian Journal of Physiology and Pharmacology
Published
1993-10-01
Volume
71
Issue
10-11
Pages
854-857
ISSN
  • 0008-4212 (ISSN-L)
  • 1205-7541
OpenAlex
W2043844167
Cited by
166
References
0
FWCI
1.95
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Predicting submaximal oxygen consumption during treadmill running in mice. https://app.cochat.ai/papers/10.1139/y93-128
The paper
Fernando, P., Bonen, A., & Hoffman-Goetz, L. (1993). Predicting submaximal oxygen consumption during treadmill running in mice. Canadian Journal of Physiology and Pharmacology. https://doi.org/10.1139/y93-128

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.