ANALYSIS AND AUTOMATIC IDENTIFICATION OF SLEEP STAGES USING HIGHER ORDER SPECTRA
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Electroencephalogram (EEG) signals are widely used to study the activity of the brain, such as to determine sleep stages. These EEG signals are nonlinear and non-stationary in nature. It is difficult to perform sleep staging by visual interpretation and linear techniques. Thus, we use a nonlinear technique, higher order spectra (HOS), to extract hidden information in the sleep EEG signal. In this study, unique bispectrum and bicoherence plots for various sleep stages were proposed. These can be used as visual aid for various diagnostics application. A number of HOS based features were extracted from these plots during the various sleep stages (Wakefulness, Rapid Eye Movement (REM), Stage 1-4 Non-REM) and they were found to be statistically significant with p-value lower than 0.001 using ANOVA test. These features were fed to a Gaussian mixture model (GMM) classifier for automatic identification. Our results indicate that the proposed system is able to identify sleep stages with an accuracy of 88.7%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Collop, N. A., Anderson, W. M., Boehlecke, B., Claman, D., Goldberg, R., Gottlieb, D. J., Hudgel, D., Sateia, M., Schwab, R., & Portable Monitoring Task Force of the American Academy of Sleep Medicine (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27032 · Cited by 1,550
The visual scoring of sleep in adults
Silber, M. H., Ancoli-Israel, S., Bonnet, M. H., Chokroverty, S., Grigg-Damberger, M. M., Hirshkowitz, M., Kapen, S., Keenan, S. A., Kryger, M. H., Penzel, T., et al. (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.26814 · Cited by 1,064 · cited 1×
“The gold standard for doing so is attended, in-laboratory polysomnography (PSG), where sleep stages are obtained by manually scoring EEG, electro-oculography (EOG) and electromyography (EMG) montages.(60) However, resource constraints have restricted access to attended, in-laboratory PSG in many countries,(27) and the…”
BackgroundDijk, D., Shanahan, T. L., Duffy, J. F., Ronda, J. M., & Czeisler, C. A. (1997) · The Journal of Physiology · doi:10.1111/j.1469-7793.1997.851ba.x · Cited by 250
Cited by
A deep learning approach for Parkinson’s disease diagnosis from EEG signals
Oh, S. L., Hagiwara, Y., Raghavendra, U., Yuvaraj, R., Arunkumar, N., Murugappan, M., & Acharya, U. R. (2020) · Neural Computing and Applications · doi:10.1007/s00521-018-3689-5 · Cited by 627
Self-citationMichielli, N., Acharya, U. R., & Molinari, F. (2019) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2019.01.013 · Cited by 383
Self-citationACHARYA, U. R., SREE, S. V., ANG, P. C. A., YANTI, R., & SURI, J. S. (2012) · International Journal of Neural Systems · doi:10.1142/s0129065712500025 · Cited by 320
Self-citationA Novel Multi-Class EEG-Based Sleep Stage Classification System
Memar, P., & Faradji, F. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2776149 · Cited by 318
A comparative review on sleep stage classification methods in patients and healthy individuals
Boostani, R., Karimzadeh, F., & Nami, M. (2017) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2016.12.004 · Cited by 316
Metadata
- Authors
- ACHARYA, U. R., CHUA, E. C.-P., CHUA, K. C., MIN, L. C., & TAMURA, T.
- Venue
- International Journal of Neural Systems
- Publisher
- World Scientific Pub Co Pte Lt
- Published
- 2010-12
- Volume
- 20
- Issue
- 06
- Pages
- 509-521
- ISSN
- 0129-0657 (ISSN-L)
- 1793-6462
- OpenAlex
- W1992296489
- Cited by
- 153
- References
- 3
- FWCI
- 9.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.