The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
AUTOMATIC DETECTION OF EPILEPTIC EEG SIGNALS USING HIGHER ORDER CUMULANT FEATURES
Abstract
The unpredictability of the occurrence of epileptic seizures makes it difficult to detect and treat this condition effectively. An automatic system that characterizes epileptic activities in EEG signals would allow patients or the people near them to take appropriate precautions, would allow clinicians to better manage the condition, and could provide more insight into these phenomena thereby revealing important clinical information. Various methods have been proposed to detect epileptic activity in EEG recordings. Because of the nonlinear and dynamic nature of EEG signals, the use of nonlinear Higher Order Spectra (HOS) features is a seemingly promising approach. This paper presents the methodology employed to extract HOS features (specifically, cumulants) from normal, interictal, and epileptic EEG segments and to use significant features in classifiers for the detection of these three classes. In this work, 300 sets of EEG data belonging to the three classes were used for feature extraction and classifier development and evaluation. The results show that the HOS based measures have unique ranges for the different classes with high confidence level (p-value < 0.0001). On evaluating several classifiers with the significant features, it was observed that the Support Vector Machine (SVM) presented a high detection accuracy of 98.5% thereby establishing the possibility of effective EEG segment classification using the proposed technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Andrzejak, R. G., Lehnertz, K., Mormann, F., Rieke, C., David, P., & Elger, C. E. (2001) · Physical Review E · doi:10.1103/physreve.64.061907 · Cited by 3,032
Artificial neural network based epileptic detection using time-domain and frequency-domain features
Srinivasan, V., Eswaran, C., & Sriraam, A. N. (2005) · Journal of Medical Systems · doi:10.1007/s10916-005-6133-1 · Cited by 417
Cited by
Acharya, U. R., Oh, S. L., Hagiwara, Y., Tan, J. H., & Adeli, H. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2017.09.017 · Cited by 1,647
Self-citationAutomated EEG analysis of epilepsy: A review
Acharya, U. R., Vinitha Sree, S., Swapna, G., Martis, R. J., & Suri, J. S. (2013) · Knowledge-Based Systems · doi:10.1016/j.knosys.2013.02.014 · Cited by 837
Self-citationAn automated system for epilepsy detection using EEG brain signals based on deep learning approach
Ullah, I., Hussain, M., Qazi, E.-U.-H., & Aboalsamh, H. (2018) · Expert Systems with Applications · doi:10.1016/j.eswa.2018.04.021 · Cited by 622
Wavelet-based EEG processing for computer-aided seizure detection and epilepsy diagnosis
Faust, O., Acharya, U. R., Adeli, H., & Adeli, A. (2015) · Seizure · doi:10.1016/j.seizure.2015.01.012 · Cited by 572
Self-citationSeizure detection, seizure prediction, and closed-loop warning systems in epilepsy
Ramgopal, S., Thome-Souza, S., Jackson, M., Kadish, N. E., Sánchez Fernández, I., Klehm, J., Bosl, W., Reinsberger, C., Schachter, S., & Loddenkemper, T. (2014) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2014.06.023 · Cited by 469
Metadata
- Authors
- ACHARYA, U. R., SREE, S. V., & SURI, J. S.
- Venue
- International Journal of Neural Systems
- Publisher
- World Scientific Pub Co Pte Lt
- Published
- 2011-10
- Volume
- 21
- Issue
- 05
- Pages
- 403-414
- ISSN
- 0129-0657 (ISSN-L)
- 1793-6462
- OpenAlex
- W2004718447
- Cited by
- 196
- References
- 2
- FWCI
- 7.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: AUTOMATIC DETECTION OF EPILEPTIC EEG SIGNALS USING HIGHER ORDER CUMULANT FEATURES. https://app.cochat.ai/papers/10.1142/s0129065711002912
- The paper
- ACHARYA, U. R., SREE, S. V., & SURI, J. S. (2011). AUTOMATIC DETECTION OF EPILEPTIC EEG SIGNALS USING HIGHER ORDER CUMULANT FEATURES. International Journal of Neural Systems. https://doi.org/10.1142/s0129065711002912
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.