Neurolight: A Deep Learning Neural Interface for Cortical Visual Prostheses

Lozano, Antonio, Suárez, Juan Sebastián, Soto-Sánchez, Cristina, Garrigós, Javier, Martínez-Alvarez, J. Javier, Ferrández, J. Manuel, Fernández, Eduardo · 2020 · International Journal of Neural Systems

Abstract

Visual neuroprosthesis, that provide electrical stimulation along several sites of the human visual system, constitute a potential tool for vision restoration for the blind. Scientific and technological progress in the fields of neural engineering and artificial vision comes with new theories and tools that, along with the dawn of modern artificial intelligence, constitute a promising framework for the further development of neurotechnology. In the framework of the development of a Cortical Visual Neuroprosthesis for the blind (CORTIVIS), we are now facing the challenge of developing not only computationally powerful tools and flexible approaches that will allow us to provide some degree of functional vision to individuals who are profoundly blind. In this work, we propose a general neuroprosthesis framework composed of several task-oriented and visual encoding modules. We address the development and implementation of computational models of the firing rates of retinal ganglion cells and design a tool — Neurolight — that allows these models to be interfaced with intracortical microelectrodes in order to create electrical stimulation patterns that can evoke useful perceptions. In addition, the developed framework allows the deployment of a diverse array of state-of-the-art deep-learning techniques for task-oriented and general image pre-processing, such as semantic segmentation and object detection in our system’s pipeline. To the best of our knowledge, this constitutes the first deep-learning-based system designed to directly interface with the visual brain through an intracortical microelectrode array. We implement the complete pipeline, from obtaining a video stream to developing and deploying task-oriented deep-learning models and predictive models of retinal ganglion cells’ encoding of visual inputs under the control of a neurostimulation device able to send electrical train pulses to a microelectrode array implanted at the visual cortex.

Overview

Integrity signals

Registry

Crossref · 10.1142/s0129065720500458

Cites

63 of 63 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 65 references

Research works printed but not linked: 12

  1. House W. F., 1976, Otol. Rhinol. Laryngol., 85, 1
  2. Mcintosh L., 2016, Advances in Neural Information Processing Systems, 29, 1369
  3. Bradski G., 2000, Dr. Dobb’s J. Softw. Tools, 25, 120
  4. Oliphant T. E., 2006, Guide to NumPy
  5. Cadieu C. F., 2014, PLoS Comput. Biol., 10, 1
  6. Marblestone A. H., 2016, Front. Comput. Neurosci., 10
  7. Roe1 A. W., 2015, Front. Neuroanat., 9, 135
  8. Lozano A., 2019, Lect. Notes Comput. Sci., 11486, 1
  9. Vicente J. M. Ferrandez, 2019, Proc. of the th Int. Work-Conf. the Interplay Between Natural and Artificial Computation
  10. Vicente J. M. Ferrandez, 2019, From Bioinspired Systems and Biomedical Applications to Machine Learning, Proc. of the th Int. Work-Conf. the Interplay Between Natural and Artificial Computation
  11. Romero S., 2008, Proc. of the First Int. Conf. Biomedical Electronics and Devices, 84
  12. Fernandez E., 2019, Invest. Ophthalmol. Vis. Sci., 60, 4021

Cited by

See all 58

Metadata

Authors
Lozano, A., Suárez, J. S., Soto-Sánchez, C., Garrigós, J., Martínez-Alvarez, J. J., Ferrández, J. M., & Fernández, E.
Affiliations
  • Universidad Politécnica de Cartagena (ES)
  • Universitat de Miguel Hernández d'Elx (ES)
  • Instituto de Bioingeniería, Universidad Miguel Hernández, 03202 Alicante, Spain
  • Departamento de Electrónica, Tecnología de Computadoras y Proyectos, Universidad Politécnica de Cartagena, 30202 Cartagena, Spain
Venue
International Journal of Neural Systems
Published
2020-07-21
Volume
30
Issue
09
Pages
2050045
ISSN
  • 0129-0657 (ISSN-L)
  • 1793-6462
OpenAlex
W3025652821
Cited by
57
References
65
Citations by year
2026: 8 · 2025: 9 · 2024: 5 · 2023: 7 · 2022: 15 · 2021: 13
FWCI
4.01
Type
journal article
Language
en
Open access
closed
Locations
  • International Journal of Neural Systems (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Fundacion Seneca Agencia de Ciencia y Tecnologia de la Region de Murcia (20041/GERM/16, 21091/PDC/19, RTI2018-098969-B-100)
  • Spanish Ministerio de Ciencia Innovacion y Universidades (PROMETEO/2019/119)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
Keywords
cortical visual prosthesis, intracortical microelectrodes, visual encoding, semantic segmentation, object detection, neurostimulation devices, visual cortex
MeSH terms
Electrocorticography, Deep Learning, Blindness, Cerebral Cortex, Equipment Design, Humans, Image Interpretation, Computer-Assisted, Models, Theoretical, Retinal Ganglion Cells, Software Design, Visual Prosthesis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Neurolight: A Deep Learning Neural Interface for Cortical Visual Prostheses. https://app.cochat.ai/papers/10.1142/s0129065720500458
The paper
Lozano, A., Suárez, J. S., Soto-Sánchez, C., Garrigós, J., Martínez-Alvarez, J. J., Ferrández, J. M., & Fernández, E. (2020). Neurolight: A Deep Learning Neural Interface for Cortical Visual Prostheses. International Journal of Neural Systems. https://doi.org/10.1142/s0129065720500458

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.