Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index; 35 of the 69 sources its claims cite were checked for support.

Visual percepts evoked with an intracortical 96-channel microelectrode array inserted in human occipital cortex

Open access
Fernández, Eduardo, Alfaro, Arantxa, Soto-Sánchez, Cristina, Gonzalez-Lopez, Pablo, Lozano, Antonio M., Peña, Sebastian, Grima, Maria Dolores, Rodil, Alfonso, Gómez, Bernardeta, Chen, Xing, Roelfsema, Pieter R., Rolston, John D., Davis, Tyler S., Normann, Richard A. · 2021 · Journal of Clinical Investigation

Abstract

BACKGROUNDA long-held goal of vision therapy is to transfer information directly to the visual cortex of blind individuals, thereby restoring a rudimentary form of sight. However, no clinically available cortical visual prosthesis yet exists.METHODSWe implanted an intracortical microelectrode array consisting of 96 electrodes in the visual cortex of a 57-year-old person with complete blindness for a 6-month period. We measured thresholds and the characteristics of the visual percepts elicited by intracortical microstimulation.RESULTSImplantation and subsequent explantation of intracortical microelectrodes were carried out without complications. The mean stimulation threshold for single electrodes was 66.8 ± 36.5 μA. We consistently obtained high-quality recordings from visually deprived neurons and the stimulation parameters remained stable over time. Simultaneous stimulation via multiple electrodes was associated with a significant reduction in thresholds (P < 0.001, ANOVA) and evoked discriminable phosphene percepts, allowing the blind participant to identify some letters and recognize object boundaries.CONCLUSIONSOur results demonstrate the safety and efficacy of chronic intracortical microstimulation via a large number of electrodes in human visual cortex, showing its high potential for restoring functional vision in the blind.TRIAL REGISTRATIONClinicalTrials.gov identifier NCT02983370.FUNDINGThe Spanish Ministerio de Ciencia Innovación y Universidades, the Generalitat Valenciana (Spain), the Europan Union's Horizon 2020 programme, the Bidons Egara Research Chair of the University Miguel Hernández (Spain), and the John Moran Eye Center of the University of Utah.

Overview

CoChat Summary

TL;DR

In a 57-year-old woman with complete blindness, a 96-channel Utah Electrode Array implanted in right occipital cortex for 6 months was safely implanted and explanted, and intracortical microstimulation evoked phosphenes via 88 of 96 electrodes. Multi-electrode stimulation produced discriminable patterned percepts that allowed identification of some letters and object boundaries, though percepts were variable and required training and calibration.

Key findings

  • Implantation and explantation occurred without complications; electrode impedances were mostly 37–56 kΩ (47 ± 4.8 kΩ), and single-electrode thresholds increased by 19.4% over the last 4 months, from 64.8 to 80.4 μA. Phosphenes were reliably evoked with 88 of 96 electrodes, with a mean single-electrode threshold of 66.8 ± 36.5 μA (range 7–128 μA).
  • Simultaneous stimulation of larger electrode groups significantly reduced thresholds (P < 0.001, ANOVA); 4-electrode thresholds averaged 48.0 ± 22.6 μA, 28% lower than single electrodes. Two-point discrimination was limited: 23.6% of pair stimulations evoked 2 discrete phosphenes, while 76.4% evoked a single phosphene that was 1.9 ± 0.1 times larger; for electrodes 400 μm apart, temporal separation >250 ms yielded 2 distinct phosphenes 90% of the time, reaching 100% at ≥565 μm separation.
  • The subject discriminated horizontal versus vertical patterns with 81.4% overall success across 22 sessions on 4 days, later reaching 100%; she reliably discriminated letters such as i, L, C, V, and O with overall success always >70%. In an O-versus-o task, performance improved to 90%–95% after 70 trials and 100% in the latest sessions.
  • With a bio-inspired retinal encoder, the subject localized a large white square with 100% accuracy across 70 trials and a smaller square with 100% accuracy across 150 trials over 5 days; reaction time decreased from 8.6 ± 0.6 seconds to 5.4 ± 0.3 seconds after 2 training days.

Methods

  • Single-subject feasibility study in a 57-year-old right-handed female with toxic optic neuropathy and complete blindness for 16 years. A Utah Electrode Array with 96 electrodes (1.5-mm shanks, 10 × 10 grid) was implanted in the right occipital cortex near the V1/V2 border and explanted after 6 months.
  • Stimulation and recording used the CereStim 96 and NeuroPort systems, with up to 16 simultaneously stimulated electrodes; sessions occurred generally 5 days per week, 1–2 times per day, up to 4 hours per session, totaling approximately 540 hours of stimulation. Thresholds were measured with a binary search procedure (1–128 μA, 1-μA minimum step, 10% catch trials), and psychometric curves were fit with a Weibull cumulative distribution function to estimate 50% detection thresholds.
  • Behavioral testing included sham-controlled detection, 2-alternative forced-choice discrimination, phosphene mapping on a digitizing tablet, subjective brightness/size ratings, two-point discrimination with varied electrode spacing and stimulus delays, and preliminary tests with a bio-inspired retinal encoder. Statistical analysis used IBM SPSS 20.0 with t tests or ANOVA and Scheffe’s procedure, with P < 0.05 considered significant.

Limitations

  • Stated: the study involved a single subject over a 6-month period, and the authors state that further investigations in more subjects and over a longer period are required; simultaneous stimulation currents can summate, possibly requiring temporal interleaving; percepts sometimes did not clearly correlate with electrode locations, suggesting spatial remapping or fine calibration may be needed; not all letters could be induced, and many stimulation patterns were not recognized as letters; wireless systems are not yet sufficiently robust for clinical use.
  • Stated: the CereStim 96 limited simultaneous stimulation to 16 electrodes, constraining the complexity of patterns that could be tested.
  • Evident from the text: outcomes depend heavily on the single participant’s subjective reports of phosphene location, brightness, size, and shape, and there was no blinding or control group, limiting generalizability and objectivity.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1172/jci151331

Cites

60 of 60 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

19 Valid · 2 Not valid · 5 Not checked · 144 Own results and interpretations

90 more claims · 1 with their cited sources checked

Create a free account to see all 170 claims and every source verdict.

See all claims — free account
  • Probably not a substantial claim. 34
  • It may state two separate claims as one. 50
  • The quote only partly states this claim. 1

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

10 more claims about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Citations

Cites

Show all 56 references

Cited by

See all 246

Metadata

Authors
Fernández, E., Alfaro, A., Soto-Sánchez, C., Gonzalez-Lopez, P., Lozano, A. M., Peña, S., Grima, M. D., Rodil, A., Gómez, B., Chen, X., Roelfsema, P. R., Rolston, J. D., Davis, T. S., & Normann, R. A.
Affiliations
  • Universitat de Miguel Hernández d'Elx (ES)
  • Netherlands Institute for Neuroscience (NL)
  • University of Utah (US)
Venue
Journal of Clinical Investigation
Published
2021-12-01
Volume
131
Issue
23
ISSN
  • 0021-9738 (ISSN-L)
  • 1558-8238
OpenAlex
W3207382873
Cited by
246
References
56
Citations by year
2026: 63 · 2025: 69 · 2024: 31 · 2023: 42 · 2022: 40 · 2021: 1
FWCI
10.33
Type
journal article
Language
en
Open access
Locations
  • Journal of Clinical Investigation (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • Pure Amsterdam UMC (publishedVersion, cc-by)
  • KNAW Research Portal (The Royal Netherlands Academy of Arts and Sciences) (publishedVersion, other-oa)
  • KNAW research portal (Royal Academy of Art and Sciences (KNAW)) (publishedVersion, other-oa)
  • VU Research Portal (publishedVersion, other-oa)
  • Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
Funders
  • Spanish Ministerio de Ciencia Innovación y Universidades (RTI2018-098969-B-100)
  • Generalitat Valenciana (PROMETEO/2019/119)
  • Bidons Egara Research Chair of the University Miguel Hernández (2019)
  • John Moran Eye Center of the University of Utah (2019)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
Keywords
cortical visual prosthesis, intracortical microelectrode arrays, microstimulation, visual percepts, phosphenes, blindness, visual cortex, stimulation threshold, vision restoration
MeSH terms
Blindness, Electric Stimulation, Electrodes, Implanted, Female, Humans, Microelectrodes, Middle Aged, Occipital Lobe, Optic Nerve Diseases, Phosphenes, Retina, Vision, Ocular, Visual Cortex, Visual Perception, Treatment Outcome, Visual Prosthesis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Visual percepts evoked with an intracortical 96-channel microelectrode array inserted in human occipital cortex. https://app.cochat.ai/papers/10.1172/jci151331
The paper
Fernández, E., Alfaro, A., Soto-Sánchez, C., Gonzalez-Lopez, P., Lozano, A. M., Peña, S., Grima, M. D., Rodil, A., Gómez, B., Chen, X., Roelfsema, P. R., Rolston, J. D., Davis, T. S., & Normann, R. A. (2021). Visual percepts evoked with an intracortical 96-channel microelectrode array inserted in human occipital cortex. Journal of Clinical Investigation. https://doi.org/10.1172/jci151331

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.