QUANTIFIED DEEP TENDON REFLEX DEVICE, SECOND GENERATION
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
The deep tendon reflex is a fundamental aspect of neurological examinations. The severity of and degree of recovery from a traumatic brain injury can be assessed by the myotatic stretch reflex. A hyperactive reflex response is correlated with spasticity, which can also be correlated with the degree of damage to the supraspinal input, in essence assessing the severity of traumatic brain injury. The myotatic stretch reflex is clinically evaluated by the National Institute of Neurological Disorders and Stroke (NINDS) reflex scale (0–4); however, this scale lacks temporal data and may also vary in interpretation. The solution is a fully quantified evaluation system of the myotatic stretch reflex, whereby a patellar hammer's force input is based on original potential energy and a microelectromechanical system (MEMS) accelerometer quantifies the output. The MEMS accelerometer is attached to a set anchor point near the ankle. The reflex amplitude is based on the maximum acceleration of the reflex response. The quantified data collected from MEMS accelerometers are transmitted by a portable computer (i.e. a Pocket PC). This paper describes a device that quantitatively evaluates the reflex response using accelerometers and that demonstrates precision for reproducibility.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The proposed method is simple and does not necessitate complicated setups compared to systems that are tethered or fixed to static or bulky structures [12], [13], [19].”
From The Validity and Reliability of Motion Analysis in Patellar Tendon Reflex Assessment (2013) · cites this paper as [19]
In the citing paper
“Such fixations on subjects might lead to discomfort and affect the natural response of a reflex 17 .”
From Motion Analysis of Normal Patellar Tendon Reflex (2013) · cites this paper as [17]
Citations
Cites
Voerman, G., Gregorič, M., & Hermens, H. (2005) · Disability and Rehabilitation · doi:10.1080/09638280400014600 · Cited by 201
Reliability of the NINDS Myotatic Reflex Scale
Litvan, I., Mangone, C. A., Werden, W., Bueri, J. A., Estol, C. J., Garcea, D. O., Rey, R. C., Sica, R. E. P., Hallett, M., & Bartko, J. J. (1996) · Neurology · doi:10.1212/wnl.47.4.969 · Cited by 92
Manschot, S., van Passel, L., Buskens, E., Algra, A., & van Gijn, J. (1998) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.64.2.253 · Cited by 86
Faist, M., Ertel, M., Berger, W., & Dietz, V. (1999) · Brain · doi:10.1093/brain/122.3.567 · Cited by 80
Biceps femoris tendon jerk reflexes are enhanced at the end of the swing phase in humans
de Crommert, H. W. A. A. V., Faist, M., Berger, W., & Duysens, J. (1996) · Brain Research · doi:10.1016/0006-8993(96)00885-2 · Cited by 62
Pagliaro, P., & Zamparo, P. (1999) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(98)00045-5 · Cited by 47
Lebiedowska, M. K., & Fisk, J. R. (2003) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(02)04946-8 · Cited by 37
Monitoring of head injury by myotatic reflex evaluation
Cozens, J. A., Miller, S., Chambers, I. R., & Mendelow, A. D. (2000) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.68.5.581 · Cited by 24
Cited by
Heinze, F., Hesels, K., Breitbach‐Faller, N., Schmitz‐Rode, T., & Dißelhorst-Klug, C. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0624-z · Cited by 104
“Furthermore, accelerometers have been successful introduced for reflex quantification [25] and the monitoring of tremor in Parkinson’s disease [43].”
MethodLemoyne, R. C., & Mastroianni, T. (2014) · Methods in molecular biology · doi:10.1007/978-1-4939-2172-0_23 · Cited by 92
Self-citationACCELEROMETERS FOR QUANTIFICATION OF GAIT AND MOVEMENT DISORDERS: A PERSPECTIVE REVIEW
Lemoyne, R. C., COROIAN, C., Mastroianni, T., & Grundfest, W. S. (2008) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519408002656 · Cited by 95
Self-citationLemoyne, R. C., Mastroianni, T., COROIAN, C., & Grundfest, W. S. (2011) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519410003733 · Cited by 45
Self-citationLemoyne, R. C., & Mastroianni, T. (2017) · InTech eBooks · doi:10.5772/intechopen.69961 · Cited by 45
Self-citationQUANTIFIED DEEP TENDON REFLEX DEVICE FOR RESPONSE AND LATENCY, THIRD GENERATION
Lemoyne, R. C., COROIAN, C., Mastroianni, T., & Grundfest, W. S. (2008) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519408002772 · Cited by 36
Self-citationWIRELESS ACCELEROMETER ASSESSMENT OF GAIT FOR QUANTIFIED DISPARITY OF HEMIPARETIC LOCOMOTION
Lemoyne, R. C., Coroian, C., Mastroianni, T., & Grundfest, W. S. (2009) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519409003024 · Cited by 34
Self-citationLemoyne, R. C., Mastroianni, T., KALE, H., LUNA, J., Stewart, J. I. M., Elliot, S., BRYAN, F., COROIAN, C., & Grundfest, W. S. (2010) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519410003654 · Cited by 34
Self-citationThe Validity and Reliability of Motion Analysis in Patellar Tendon Reflex Assessment
Tham, L. K., Abu Osman, N. A., Wan Abas, W. A. B., & Lim, K. S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0055702 · Cited by 32
“Other methods include attaching force transducer [18] and accelerometer [17,19] to the joint.”
Influence of Age on Patellar Tendon Reflex Response
Chandrasekhar, A., Abu Osman, N. A., Tham, L. K., Lim, K. S., & Wan Abas, W. A. B. (2013) · PLoS ONE · doi:10.1371/journal.pone.0080799 · Cited by 31
WIRELESS THREE DIMENSIONAL ACCELEROMETER REFLEX QUANTIFICATION DEVICE WITH ARTIFICIAL REFLEX SYSTEM
Lemoyne, R. C., Mastroianni, T., COROIAN, C., & Grundfest, W. S. (2010) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519410003472 · Cited by 21
Self-citationPortable Wearable and Wireless Systems for Gait and Reflex Response Quantification
Lemoyne, R. C., & Mastroianni, T. (2017) · Smart sensors, measurement and instrumentation · doi:10.1007/978-981-10-5684-0_5 · Cited by 12
Self-citationLemoyne, R. C., & Mastroianni, T. (2017) · Smart sensors, measurement and instrumentation · doi:10.1007/978-981-10-5684-0_7 · Cited by 11
Self-citationLemoyne, R. C., & Mastroianni, T. (2021) · IntechOpen eBooks · doi:10.5772/intechopen.95550 · Cited by 7
Self-citationLemoyne, R. C., Mastroianni, T., Whiting, D. M., & Tomycz, N. D. (2019) · Smart sensors, measurement and instrumentation · doi:10.1007/978-981-13-5808-1_3 · Cited by 7
Self-citationQuantification Systems Appropriate for a Clinical Setting
Lemoyne, R. C., & Mastroianni, T. (2017) · Smart sensors, measurement and instrumentation · doi:10.1007/978-981-10-5684-0_3 · Cited by 6
Self-citationMotion Analysis of Normal Patellar Tendon Reflex
Tham, L. K., Osman, N. A. A., Abas, W. A. B. W., & Lim, K. S. (2013) · Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques · doi:10.1017/s0317167100015985 · Cited by 4
Uslu, S., Nüzket, T., Gürbüz, M., & Uysal, H. (2022) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-022-02638-5 · Cited by 4
“However, evaluating only with EMG responses does not provide information about the temporal characteristics of the reflex response [12, 39].”
BackgroundTraditional Clinical Evaluation of Gait and Reflex Response by Ordinal Scale
Lemoyne, R. C., & Mastroianni, T. (2017) · Smart sensors, measurement and instrumentation · doi:10.1007/978-981-10-5684-0_2 · Cited by 3
Self-citationKareem, S. K., Dilara, K., Maruthy, K. N., Johnson, P., & Kumar, A. V. S. (2021) · Clinical Epidemiology and Global Health · doi:10.1016/j.cegh.2021.100881 · Cited by 2
Cho, M. K., Lee, I., Kwon, J.-N., Shin, B. C., Ko, S., Ko, H. Y., Shin, Y. I., & Hong, J. W. (2015) · 대한한의학회지 · doi:10.13048/jkm.15029 · Cited by 2
Wearable and Wireless Systems for Gait Analysis and Reflex Quantification
Lemoyne, R. C., & Mastroianni, T. (2017) · Smart sensors, measurement and instrumentation · doi:10.1007/978-981-10-5684-0_1 · Cited by 2
Self-citationThe Rise of Inertial Measurement Units
Lemoyne, R. C., & Mastroianni, T. (2017) · Smart sensors, measurement and instrumentation · doi:10.1007/978-981-10-5684-0_4 · Cited by 2
Self-citationYIKEMOTO, Y., Yu, W., & Acharya, U. R. (2011) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519411004204 · Cited by 1
Portable Wearable and Wireless Systems for Gait and Reflex Response Quantification
Lemoyne, R. C., & Mastroianni, T. (2024) · Smart sensors, measurement and instrumentation · doi:10.1007/978-981-97-2439-0_5 · Cited by 1
Self-citationWearable and Wireless Systems for Movement Disorder Evaluation and Deep Brain Stimulation Systems
Lemoyne, R. C., Mastroianni, T., Whiting, D. M., & Tomycz, N. D. (2019) · Smart sensors, measurement and instrumentation · doi:10.1007/978-981-13-5808-1_1 · Cited by 1
Self-citationDIFFERING ISOMETRIC CONTRACTIONS CAN AFFECT NEURAL EXCITABILITY
Wyld, K. (2011) · University of Bedfordshire Repository (University of Bedfordshire)
Wearable and Wireless Systems for Gait Analysis and Reflex Quantification
Lemoyne, R. C., & Mastroianni, T. (2024) · Smart sensors, measurement and instrumentation · doi:10.1007/978-981-97-2439-0_1
Self-citationQuantification Systems Appropriate for a Clinical Setting
Lemoyne, R. C., & Mastroianni, T. (2024) · Smart sensors, measurement and instrumentation · doi:10.1007/978-981-97-2439-0_3
Self-citationLemoyne, R. C., & Mastroianni, T. (2024) · Smart sensors, measurement and instrumentation · doi:10.1007/978-981-97-2439-0_7
Self-citationTraditional Clinical Evaluation of Gait and Reflex Response by Ordinal Scale
Lemoyne, R. C., & Mastroianni, T. (2024) · Smart sensors, measurement and instrumentation · doi:10.1007/978-981-97-2439-0_2
Self-citationThe Rise of Inertial Measurement Units
Lemoyne, R. C., & Mastroianni, T. (2024) · Smart sensors, measurement and instrumentation · doi:10.1007/978-981-97-2439-0_4
Self-citationLemoyne, R. C., Mastroianni, T., Whiting, D. M., & Tomycz, N. D. (2024) · Smart sensors, measurement and instrumentation · doi:10.1007/978-981-97-4635-4_3
Self-citationWearable and Wireless Systems for Movement Disorder Evaluation and Deep Brain Stimulation Systems
Lemoyne, R. C., Mastroianni, T., Whiting, D. M., & Tomycz, N. D. (2024) · Smart sensors, measurement and instrumentation · doi:10.1007/978-981-97-4635-4_1
Self-citation
Metadata
- Authors
- LEMOYNE, R., DABIRI, F., & JAFARI, R.
- Affiliations
- University of California, Los Angeles (US)
- Venue
- Journal of Mechanics in Medicine and Biology
- Publisher
- World Scientific Pub Co Pte Lt
- Published
- 2008-03
- Volume
- 08
- Issue
- 01
- Pages
- 75-85
- ISSN
- 0219-5194 (ISSN-L)
- 1793-6810
- OpenAlex
- W2093346634
- Cited by
- 34
- References
- 8
- Citations by year
- 2024: 8 · 2022: 1 · 2021: 2 · 2019: 2 · 2017: 7 · 2015: 1 · 2014: 1 · 2013: 3
- FWCI
- 2.22
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Mechanics in Medicine and Biology (publishedVersion)
- Funders
- National Science Foundation
- Topics
- Health Sciences › Medicine › Clinical Neurology › Traumatic Brain Injury Research
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Neurology › Neurology and Historical Studies
- Keywords
- deep tendon reflexes, traumatic brain injury, spasticity, MEMS accelerometer, neurological assessment, portable data acquisition
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.