Microengineered cell and tissue systems for drug screening and toxicology applications: Evolution of in-vitro liver technologies
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
The liver performs many key functions, the most prominent of which is serving as the metabolic hub of the body. For this reason, the liver is the focal point of many investigations aimed at understanding an organism's toxicological response to endogenous and exogenous challenges. Because so many drug failures have involved direct liver toxicity or other organ toxicity from liver generated metabolites, the pharmaceutical industry has constantly sought superior, predictive in-vitro models that can more quickly and efficiently identify problematic drug candidates before they incur major development costs, and certainly before they are released to the public. In this broad review, we present a survey and critical comparison of in-vitro liver technologies along a broad spectrum, but focus on the current renewed push to develop "organs-on-a-chip". One prominent set of conclusions from this review is that while a large body of recent work has steered the field towards an ever more comprehensive understanding of what is needed, the field remains in great need of several key advances, including establishment of standard characterization methods, enhanced technologies that mimic the in-vivo cellular environment, and better computational approaches to bridge the gap between the in-vitro and in-vivo results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A General Model for the Origin of Allometric Scaling Laws in Biology
West, G. B., Brown, J. H., & Enquist, B. J. (1997) · Science · doi:10.1126/science.276.5309.122 · Cited by 5,016
The price of innovation: new estimates of drug development costs
DiMasi, J. A., Hansen, R. W., & Grabowski, H. G. (2003) · Journal of Health Economics · doi:10.1016/s0167-6296(02)00126-1 · Cited by 4,265
Can the pharmaceutical industry reduce attrition rates?
Kola, I., & Landis, J. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1470 · Cited by 4,167
Hepatic Stellate Cells: Protean, Multifunctional, and Enigmatic Cells of the Liver
Friedman, S. L. (2008) · Physiological Reviews · doi:10.1152/physrev.00013.2007 · Cited by 2,842
ACETAMINOPHEN-INDUCED HEPATIC NECROSIS. IV. PROTECTIVE ROLE OF GLUTATHIONE
Mitchell, J. R., Jollow, D. J., Potter, W. Z., Gillette, J. R., & Brodie, B. B. (1973) · The Journal of Pharmacology and Experimental Therapeutics · doi:10.1016/s0022-3565(25)29666-5 · Cited by 1,737
Martignoni, M., Groothuis, G. M. M., & de Kanter, R. (2006) · Expert Opinion on Drug Metabolism & Toxicology · doi:10.1517/17425255.2.6.875 · Cited by 1,478
Uygun, B. E., Soto-Gutierrez, A., Yagi, H., Izamis, M.-L., Guzzardi, M. A., Shulman, C., Milwid, J., Kobayashi, N., Tilles, A., Berthiaume, F., et al. (2010) · Nature Medicine · doi:10.1038/nm.2170 · Cited by 1,370
Self-citationMicroscale culture of human liver cells for drug development
Khetani, S. R., & Bhatia, S. N. (2008) · Nature Biotechnology · doi:10.1038/nbt1361 · Cited by 1,219
Idiosyncratic drug hepatotoxicity
Kaplowitz, N. (2005) · Nature Reviews Drug Discovery · doi:10.1038/nrd1750 · Cited by 1,054
Crispe, I. N. (2009) · Annual Review of Immunology · doi:10.1146/annurev.immunol.021908.132629 · Cited by 986
Cited by
Menya, E., Olupot, P. W., Storz, H., Lubwama, M., & Kiros, Y. (2018) · Chemical Engineering Research and Design · doi:10.1016/j.cherd.2017.11.008 · Cited by 319
Gökaltun, A., Kang, Y. B., Yarmush, M. L., Usta, O. B., & Asatekin, A. (2019) · Scientific Reports · doi:10.1038/s41598-019-43625-5 · Cited by 269
Self-citationLong‐term maintenance of a microfluidic 3D human liver sinusoid
Prodanov, L., Jindal, R., Bale, S. S., Hegde, M., McCarty, W. J., Golberg, I., Bhushan, A., Yarmush, M. L., & Usta, O. B. (2016) · Biotechnology and Bioengineering · doi:10.1002/bit.25700 · Cited by 214
“Microfluidic platforms have been shown to allow the creation of an artificially engineered, physiologically relevant cell culture microenvironment, which is not possible using standard plate cultures (Polini et al. 2014; Usta et al. 2015).”
BackgroundMethodSelf-citationMetabolic Patterning on a Chip: Towards in vitro Liver Zonation of Primary Rat and Human Hepatocytes
Kang, Y. B., Eo, J., Mert, S., Yarmush, M. L., & Usta, O. B. (2018) · Scientific Reports · doi:10.1038/s41598-018-27179-6 · Cited by 122
Self-citationMicrofluidic Liver-on-a-Chip for Preclinical Drug Discovery
Fu, J., Qiu, H., & Tan, C. S. (2023) · Pharmaceutics · doi:10.3390/pharmaceutics15041300 · Cited by 42
Metadata
- Authors
- Usta, O. B., McCarty, W. J., Bale, S., Hegde, M., Jindal, R., Bhushan, A., Golberg, I., & Yarmush, M. L.
- Venue
- TECHNOLOGY
- Publisher
- World Scientific Pub Co Pte Ltd
- Published
- 2015-03
- Volume
- 03
- Issue
- 01
- Pages
- 1-26
- ISSN
- 2339-5478 (ISSN-L)
- 2345-7740
- OpenAlex
- W2016936251
- Cited by
- 85
- References
- 31
- FWCI
- 5.50
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microengineered cell and tissue systems for drug screening and toxicology applications: Evolution of in-vitro liver technologies. https://app.cochat.ai/papers/10.1142/s2339547815300012
- The paper
- Usta, O. B., McCarty, W. J., Bale, S., Hegde, M., Jindal, R., Bhushan, A., Golberg, I., & Yarmush, M. L. (2015). Microengineered cell and tissue systems for drug screening and toxicology applications: Evolution of in-vitro liver technologies. TECHNOLOGY. https://doi.org/10.1142/s2339547815300012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.