Terahertz Sensing of Thin Poly(ethylene Terephthalate) Film Thickness Using a Metallic Mesh
Open accessAbstract
A metallic mesh, i.e., a metallic thin film with regularly spaced openings, works as a band-pass filter in the terahertz region. The filter's transmittance is far higher than the open-area ratio and its transmission spectrum is affected by the index of refraction in and above the openings. Therefore, metallic-mesh films can be used as high-sensitivity sensing or imaging conduits if samples adhere to the metal surface. Here, we report on our success in detecting 1-µm-thickness differences in poly(ethylene terephthalate) (PET) films and recording two-dimensional (2D) images using metallic-mesh sensing and imaging applications.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Several methods have been reported to lower the detection threshold for terahertz thin-film sensing, such as difference signals, metamaterial resonance shifts, and metal meshes.
“Various techniques have been reported to improve the detection threshold for THz thin film sensing, e. g., evaluation of difference signals, 3 resonance changes of metamaterials, 4 or the application of metal meshes to enhance the amplitude reduction of the THz bandpass.5”
From Highly sensitive terahertz measurement of layer thickness using a two-cylinder waveguide sensor (2010) · cites this paper as [5]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Optical properties of Au, Ni, and Pb at submillimeter wavelengths
Ordal, M. A., Bell, R. J., Alexander, R. W., et al. (1987) · Applied Optics · doi:10.1364/ao.26.000744 · Cited by 303 · see citing works
Terahertz sensing method for protein detection using a thin metallic mesh
Yoshida, H., Ogawa, Y., Kawai, Y., Hayashi, S., Hayashi, A., Otani, C., Kato, E., Miyamaru, F., & Kawase, K. (2007) · Applied Physics Letters · doi:10.1063/1.2825411 · Cited by 187 · see citing works
Self-citationMetallodielectric gratings with subwavelength slots: Optical properties
Steele, J. M., Moran, C. E., Lee, A., et al. (2003) · Physical review. B, Condensed matter · doi:10.1103/physrevb.68.205103 · Cited by 118 · see citing works
Terahertz electric response of fractal metamaterial structures
Miyamaru, F., Saito, Y., Takeda, M. W., et al. (2008) · Physical Review B · doi:10.1103/physrevb.77.045124 · Cited by 85 · see citing works
Effect of a thin dielectric layer on terahertz transmission characteristics for metal hole arrays
Tanaka, M., Miyamaru, F., Hangyo, M., et al. (2005) · Optics Letters · doi:10.1364/ol.30.001210 · Cited by 78 · see citing works
Tanaka, T., Akazawa, M., Sano, E., et al. (2006) · Japanese Journal of Applied Physics · doi:10.1143/jjap.45.4058 · Cited by 14 · see citing works
Flagged first, then by citations
Research works printed but not linked: 13
- A. K. Azad, Y. Zhao, W. Zhang, and M. He: Opt. Lett. 31 (2006) 2637. · DOI
- R. Ulrich: Infrared Phys. 7 (1967) 37. · DOI
- K. Sakai, T. Fukui, Y. Tsunawaki, and H. Yoshinaga: Jpn. J. Appl. Phys. 8 (1969) 1046. · DOI
- F. Miyamaru, M. Tanaka, and M. Hangyo: Phys. Rev. B 74 (2006) 153416. · DOI
- C.-C. Chen: IEEE Trans. Microwave Theory Tech. 21 (1973) 1.
- S. A. Kuznetsov, V. V. Kubarev, P. V. Kalinin, and N. A. Vinokurov: Conf. Dig. Int. Conf. Infrared and Millimeter Waves/THz Electronics, 2007, p. 303.
- E. Kato, S. Yoshida, H. Yoshida, A. Hayashi, S. Hayashi, Y. Ogawa, C. Otani, and K. Kawase: Conf. Dig. Int. Conf. Infrared and Millimeter Waves/THz Electronics, 2007, p. 1012.
- P. Vogel and L. Genzel: Infrared Phys. 4 (1964) 257. · DOI
- T. W. Ebbesen, H. J. Lezec, H. F. Ghaemi, T. Thio, and P. A. Wolff: Nature 391 (1998) 667. · DOI
- M. Sarrazin, J. P. Vigneron, and J. M. Vigoureux: Phys. Rev. B 67 (2003) 085415. · DOI
- M. Akazawa, Y. Yamazaki, and E. Sano: Jpn. J. Appl. Phys. 44 (2005) L1481. · DOI
- J. B. Pendry, L. Martin-Moreno, and F. J. Garcia-Vidal: Science 305 (2004) 847. · DOI
- F. Miyamaru, M. Tanaka, and M. Hangyo: Phys. Rev. B 74 (2006) 153416. · DOI
Cited by
Sorted by citations
Highly sensitive terahertz measurement of layer thickness using a two-cylinder waveguide sensor
Theuer, M., Beigang, R., & Grischkowsky, D. (2010) · Applied Physics Letters · doi:10.1063/1.3481080 · Cited by 38 · see citing works
- Authors
- Yoshida, S., Kato, E., Suizu, K., Nakagomi, Y., Ogawa, Y., & Kawase, K.
- Affiliations
- Nagoya University (JP)
- Advantest (Japan) (JP)
- Tohoku University (JP)
- Venue
- Applied Physics Express
- Publisher
- IOP Publishing
- Published
- 2009-01-16
- Volume
- 2
- Issue
- 1
- Pages
- 012301
- ISSN
- 1882-0778 (ISSN-L)
- 1882-0786
- OpenAlex
- W1969091702
- Cited by
- 31
- References
- 6
- Citations by year
- 2025: 1 · 2023: 1 · 2022: 1 · 2021: 1 · 2019: 1 · 2018: 1 · 2017: 2 · 2015: 1 · 2014: 4 · 2013: 8 · 2012: 2
- FWCI
- 2.64
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Applied Physics Express (publishedVersion)
- Funders
- Ministry of Education, Culture, Sports, Science and Technology
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Metamaterials and Metasurfaces Applications
- Physical Sciences › Physics and Astronomy › Astronomy and Astrophysics › Superconducting and THz Device Technology
- Keywords
- terahertz sensing, metal mesh, PET film, film thickness measurement, transmission spectra, refractive index, terahertz imaging, two-dimensional imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review