CoChat

One-Dimensional Optical Lattice Clock with a Fermionic171Yb Isotope

Open access
Kohno, Takuya, Yasuda, Masami, Hosaka, Kazumoto, Inaba, Hajime, Nakajima, Yoshiaki, Hong, Feng-Lei · 2009 · Applied Physics Express
Cited by 98

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

We demonstrate a one-dimensional optical lattice clock with ultracold 171 Yb atoms, which is free from the linear Zeeman effect. The absolute frequency of the 1 S 0 ( F = 1/2)– 3 P 0 ( F = 1/2) clock transition in 171 Yb is determined to be 518 295 836 590 864(28) Hz with respect to the SI second.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1143/apex.2.072501

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 98

Metadata

Authors
Kohno, T., Yasuda, M., Hosaka, K., Inaba, H., Nakajima, Y., & Hong, F.-L.
Venue
Applied Physics Express
Published
2009-06-19
Volume
2
Pages
072501
ISSN
  • 1882-0778 (ISSN-L)
  • 1882-0786
OpenAlex
W1998096499
Cited by
98
References
3
FWCI
7.06
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: One-Dimensional Optical Lattice Clock with a Fermionic171Yb Isotope. https://app.cochat.ai/papers/10.1143/apex.2.072501
The paper
Kohno, T., Yasuda, M., Hosaka, K., Inaba, H., Nakajima, Y., & Hong, F.-L. (2009). One-Dimensional Optical Lattice Clock with a Fermionic171Yb Isotope. Applied Physics Express. https://doi.org/10.1143/apex.2.072501

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.