CoChat

Using multiple energy gears in MPI programs on a power-scalable cluster

Freeh, Vincent W., Lowenthal, David K. · 2005 · Proceedings of the tenth ACM SIGPLAN symposium on Principles and practice of parallel programming
Cited by 208

The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.

Abstract

Recently, system architects have built low-power, high-performance clusters, such as Green Destiny. The idea behind these clusters is to improve the energy efficiency of nodes. However, these clusters save power at the expense of performance. Our approach is instead to use high-performance cluster nodes that are frequency- and voltage-scalable; energy can than be saved by scaling down the CPU. Our prior work has examined the costs and benefits of executing an entire application at a single reduced frequency.This paper presents a framework for executing a single application in several frequency-voltage settings. The basic idea is to first divide programs into phases and then execute a series of experiments, with each phase assigned a prescribed frequency. During each experiment, we measure energy consumption and time and then use a heuristic to choose the assignment of frequency to phase for the next experiment.Our results show that significant energy can be saved without an undue performance penalty; particularly, our heuristic finds assignments of frequency to phase that is superior to any fixed-frequency solution. Specifically, this paper shows that more than half of the NAS benchmarks exhibit a better energy-time tradeoff using multiple gears than using a single gear. For example, IS using multiple gears uses 9% less energy and executes in 1% less time than the closest single-gear solution. Compared to no frequency scaling, multiple gear IS uses 16% less energy while executing only 1% longer.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1145/1065944.1065967

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Managing energy and server resources in hosting centers

    Chase, J. S., Anderson, D. C., Thakar, P. N., Vahdat, A. M., & Doyle, R. P. (2001) · Proceedings of the eighteenth ACM symposium on Operating systems principles · doi:10.1145/502034.502045 · Cited by 1,284 · cited 1×

    “In [ 9 ], Chase et al. illustrate a method to determine the aggregate system load and then determine the minimal set of servers that can handle that load.”
    Method
  • Scheduling for Reduced CPU Energy

    Weiser, M., Welch, B., Demers, A., & Shenker, S. (2007) · The Kluwer International Series in Engineering and Computer Science · doi:10.1007/978-0-585-29603-6_17 · Cited by 1,181 · cited 1×

    “One important avenue of application-level research on mobile devices focuses on collaboration with the OS [46, 65, 70, 71, 72, 21, 20, 2].”
    Background
  • Real-time dynamic voltage scaling for low-power embedded operating systems

    Pillai, P., & Shin, K. G. (2001) · Proceedings of the eighteenth ACM symposium on Operating systems principles · doi:10.1145/502034.502044 · Cited by 1,138 · cited 1×

    “In terms of research on device-specific energy savings, there is work in the CPU via dynamic voltage scaling [19, 26, 52, 57, 25, 27, 34, 39, 44, 51, 53, 56, 58, 43, 49], the disk via spindown ( e.g. , [31, 15, 66, 3, 42]), and on the memory or network [13, 40, 10, 36, 69, 68, 7, 8, 12, 37, 62, 38].”
    Background
  • Agile application-aware adaptation for mobility

    Noble, B. D., Satyanarayanan, M., Narayanan, D., Tilton, J. E., Flinn, J., & Walker, K. R. (1997) · Proceedings of the sixteenth ACM symposium on Operating systems principles · doi:10.1145/268998.266708 · Cited by 736

  • Energy dissipation in general purpose microprocessors

    Gonzalez, R., & Horowitz, M. (1996) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.535411 · Cited by 644 · cited 1×

    “It could be energy-delay or energy-delay squared, the latter proposed in [45, 24], which has been adopted by Cameron et al. [5] for use in power-aware, high-performance computing.”
    Method
  • Energy-aware adaptation for mobile applications

    Flinn, J., & Satyanarayanan, M. (1999) · Proceedings of the seventeenth ACM symposium on Operating systems principles · doi:10.1145/319151.319155 · Cited by 596 · cited 1×

    “One important avenue of application-level research on mobile devices focuses on collaboration with the OS [46, 65, 70, 71, 72, 21, 20, 2].”
    Background
  • Load balancing and unbalancing for power and performance in cluster-based systems

    Bianchini, R., Carrera, E. V., Heath, T., & Pinheiro, E. (2001) · doi:10.7282/t3-agfw-yt73 · Cited by 479 · cited 1×

    “A similar idea leverages work in cluster load balancing to determine when to turn machines on or off to handle a given load [54, 55 ].”
    Background
  • Energy management for commercial servers

    Lefurgy, C., Rajamani, K., Rawson, F., Felter, W., Kistler, M., & Keller, T. W. (2003) · Computer · doi:10.1109/mc.2003.1250880 · Cited by 473 · cited 1×

    “Such work shows that power and energy management are critical for commercial workloads, especially web servers [4, 41 ].”
    Background
  • Comparing algorithm for dynamic speed-setting of a low-power CPU

    Govil, K., Chan, E., & Wasserman, H. (1995) · Proceedings of the 1st annual international conference on Mobile computing and networking - MobiCom '95 · doi:10.1145/215530.215546 · Cited by 454 · cited 1×

    “In terms of research on device-specific energy savings, there is work in the CPU via dynamic voltage scaling [19, 26, 52, 57, 25, 27, 34, 39, 44, 51, 53, 56, 58, 43, 49], the disk via spindown ( e.g. , [31, 15, 66, 3, 42]), and on the memory or network [13, 40, 10, 36, 69, 68, 7, 8, 12, 37, 62, 38].”
    Background
  • PowerScope: a tool for profiling the energy usage of mobile applications

    Flinn, J., & Satyanarayanan, M. (1999) · Proceedings WMCSA'99. Second IEEE Workshop on Mobile Computing Systems and Applications · doi:10.1109/mcsa.1999.749272 · Cited by 433 · cited 1×

    “One important avenue of application-level research on mobile devices focuses on collaboration with the OS [46, 65, 70, 71, 72, 21 , 20, 2]. Such application-related approaches are complementary to our approach.”
    Background

Show all 38 references

Cited by

Metadata

Authors
Freeh, V. W., & Lowenthal, D. K.
Venue
Proceedings of the tenth ACM SIGPLAN symposium on Principles and practice of parallel programming
Publisher
ACM
Published
2005-06-15
Pages
164-173
OpenAlex
W2031136586
Cited by
208
References
38
FWCI
9.29
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.