Using multiple energy gears in MPI programs on a power-scalable cluster
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Recently, system architects have built low-power, high-performance clusters, such as Green Destiny. The idea behind these clusters is to improve the energy efficiency of nodes. However, these clusters save power at the expense of performance. Our approach is instead to use high-performance cluster nodes that are frequency- and voltage-scalable; energy can than be saved by scaling down the CPU. Our prior work has examined the costs and benefits of executing an entire application at a single reduced frequency.This paper presents a framework for executing a single application in several frequency-voltage settings. The basic idea is to first divide programs into phases and then execute a series of experiments, with each phase assigned a prescribed frequency. During each experiment, we measure energy consumption and time and then use a heuristic to choose the assignment of frequency to phase for the next experiment.Our results show that significant energy can be saved without an undue performance penalty; particularly, our heuristic finds assignments of frequency to phase that is superior to any fixed-frequency solution. Specifically, this paper shows that more than half of the NAS benchmarks exhibit a better energy-time tradeoff using multiple gears than using a single gear. For example, IS using multiple gears uses 9% less energy and executes in 1% less time than the closest single-gear solution. Compared to no frequency scaling, multiple gear IS uses 16% less energy while executing only 1% longer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Managing energy and server resources in hosting centers
Chase, J. S., Anderson, D. C., Thakar, P. N., Vahdat, A. M., & Doyle, R. P. (2001) · Proceedings of the eighteenth ACM symposium on Operating systems principles · doi:10.1145/502034.502045 · Cited by 1,284 · cited 1×
“In [ 9 ], Chase et al. illustrate a method to determine the aggregate system load and then determine the minimal set of servers that can handle that load.”
MethodScheduling for Reduced CPU Energy
Weiser, M., Welch, B., Demers, A., & Shenker, S. (2007) · The Kluwer International Series in Engineering and Computer Science · doi:10.1007/978-0-585-29603-6_17 · Cited by 1,181 · cited 1×
“One important avenue of application-level research on mobile devices focuses on collaboration with the OS [46, 65, 70, 71, 72, 21, 20, 2].”
BackgroundReal-time dynamic voltage scaling for low-power embedded operating systems
Pillai, P., & Shin, K. G. (2001) · Proceedings of the eighteenth ACM symposium on Operating systems principles · doi:10.1145/502034.502044 · Cited by 1,138 · cited 1×
“In terms of research on device-specific energy savings, there is work in the CPU via dynamic voltage scaling [19, 26, 52, 57, 25, 27, 34, 39, 44, 51, 53, 56, 58, 43, 49], the disk via spindown ( e.g. , [31, 15, 66, 3, 42]), and on the memory or network [13, 40, 10, 36, 69, 68, 7, 8, 12, 37, 62, 38].”
BackgroundAgile application-aware adaptation for mobility
Noble, B. D., Satyanarayanan, M., Narayanan, D., Tilton, J. E., Flinn, J., & Walker, K. R. (1997) · Proceedings of the sixteenth ACM symposium on Operating systems principles · doi:10.1145/268998.266708 · Cited by 736
Energy dissipation in general purpose microprocessors
Gonzalez, R., & Horowitz, M. (1996) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.535411 · Cited by 644 · cited 1×
“It could be energy-delay or energy-delay squared, the latter proposed in [45, 24], which has been adopted by Cameron et al. [5] for use in power-aware, high-performance computing.”
MethodEnergy-aware adaptation for mobile applications
Flinn, J., & Satyanarayanan, M. (1999) · Proceedings of the seventeenth ACM symposium on Operating systems principles · doi:10.1145/319151.319155 · Cited by 596 · cited 1×
“One important avenue of application-level research on mobile devices focuses on collaboration with the OS [46, 65, 70, 71, 72, 21, 20, 2].”
BackgroundLoad balancing and unbalancing for power and performance in cluster-based systems
Bianchini, R., Carrera, E. V., Heath, T., & Pinheiro, E. (2001) · doi:10.7282/t3-agfw-yt73 · Cited by 479 · cited 1×
“A similar idea leverages work in cluster load balancing to determine when to turn machines on or off to handle a given load [54, 55 ].”
BackgroundEnergy management for commercial servers
Lefurgy, C., Rajamani, K., Rawson, F., Felter, W., Kistler, M., & Keller, T. W. (2003) · Computer · doi:10.1109/mc.2003.1250880 · Cited by 473 · cited 1×
“Such work shows that power and energy management are critical for commercial workloads, especially web servers [4, 41 ].”
BackgroundComparing algorithm for dynamic speed-setting of a low-power CPU
Govil, K., Chan, E., & Wasserman, H. (1995) · Proceedings of the 1st annual international conference on Mobile computing and networking - MobiCom '95 · doi:10.1145/215530.215546 · Cited by 454 · cited 1×
“In terms of research on device-specific energy savings, there is work in the CPU via dynamic voltage scaling [19, 26, 52, 57, 25, 27, 34, 39, 44, 51, 53, 56, 58, 43, 49], the disk via spindown ( e.g. , [31, 15, 66, 3, 42]), and on the memory or network [13, 40, 10, 36, 69, 68, 7, 8, 12, 37, 62, 38].”
BackgroundPowerScope: a tool for profiling the energy usage of mobile applications
Flinn, J., & Satyanarayanan, M. (1999) · Proceedings WMCSA'99. Second IEEE Workshop on Mobile Computing Systems and Applications · doi:10.1109/mcsa.1999.749272 · Cited by 433 · cited 1×
“One important avenue of application-level research on mobile devices focuses on collaboration with the OS [46, 65, 70, 71, 72, 21 , 20, 2]. Such application-related approaches are complementary to our approach.”
BackgroundImproving dynamic voltage scaling algorithms with PACE
Lorch, J. R., & Smith, A. J. (2001) · Proceedings of the 2001 ACM SIGMETRICS international conference on Measurement and modeling of computer systems · doi:10.1145/378420.378429 · Cited by 386 · cited 1×
“In terms of research on device-specific energy savings, there is work in the CPU via dynamic voltage scaling [19, 26, 52, 57, 25, 27, 34, 39, 44, 51, 53, 56, 58, 43, 49], the disk via spindown ( e.g. , [31, 15, 66, 3, 42]), and on the memory or network [13, 40, 10, 36, 69, 68, 7, 8, 12, 37, 62, 38].”
BackgroundECOSystem: managing energy as a first class operating system resource
Zeng, H., Ellis, C. S., Lebeck, A. R., & Vahdat, A. (2002) · Proceedings of the 10th international conference on Architectural support for programming languages and operating systems · doi:10.1145/605397.605411 · Cited by 375
Lebeck, A. R., Fan, X., Zeng, H., & Ellis, C. (2000) · ACM SIGPLAN Notices · doi:10.1145/356989.356999 · Cited by 370 · cited 1×
“In terms of research on device-specific energy savings, there is work in the CPU via dynamic voltage scaling [19, 26, 52, 57, 25, 27, 34, 39, 44, 51, 53, 56, 58, 43, 49], the disk via spindown ( e.g. , [31, 15, 66, 3, 42]), and on the memory or network [13, 40, 10, 36, 69, 68, 7, 8, 12, 37, 62, 38].”
BackgroundEnergy-Efficient Server Clusters
Elnozahy, E. N. M., Kistler, M., & Rajamony, R. (2002) · Cited by 344
Dynamic voltage scaling on a low-power microprocessor
Pouwelse, J., Langendoen, K., & Sips, H. (2001) · Proceedings of the 7th annual international conference on Mobile computing and networking · doi:10.1145/381677.381701 · Cited by 343 · cited 1×
“In terms of research on device-specific energy savings, there is work in the CPU via dynamic voltage scaling [19, 26, 52, 57, 25, 27, 34, 39, 44, 51, 53, 56, 58, 43, 49], the disk via spindown ( e.g. , [31, 15, 66, 3, 42]), and on the memory or network [13, 40, 10, 36, 69, 68, 7, 8, 12, 37, 62, 38].”
BackgroundAdaptive Disk Spin-Down Policies for Mobile Computers.
Douglis, F., & Krishnan, P. (1995) · Cited by 334
Conserving disk energy in network servers
Carrera, E. V., Pinheiro, E., & Bianchini, R. (2003) · International Conference on Supercomputing · doi:10.1145/782814.782829 · Cited by 321 · cited 1×
“One study of four energy conservation schemes concludes that reducing the spindle speed of disks is the only viable option for server farms [6].”
BackgroundGe, R., Feng, X., & Cameron, K. W. (2005) · ACM/IEEE SC 2005 Conference (SC'05) · doi:10.1109/sc.2005.57 · Cited by 315
Policies for dynamic clock scheduling
Grunwald, D. C., Morrey, C. B., Levis, P. A., Neufeld, M., & Farkas, K. I. (2000) · doi:10.5555/1251229.1251235 · Cited by 286
Software strategies for portable computer energy management
Lorch, J. R., & Smith, A. J. (1998) · IEEE Personal Communications · doi:10.1109/98.683740 · Cited by 273 · cited 1×
“In terms of research on device-specific energy savings, there is work in the CPU via dynamic voltage scaling [19, 26, 52, 57, 25, 27, 34, 39, 44, 51, 53, 56, 58, 43, 49], the disk via spindown ( e.g. , [31, 15, 66, 3, 42]), and on the memory or network [13, 40, 10, 36, 69, 68, 7, 8, 12, 37, 62, 38].”
BackgroundPower management techniques for mobile communication
Kravets, R. H., & Krishnan, P. (1998) · ACM Annual International Conference on Mobile Computing and Networking (MobiCom) · doi:10.1145/288235.288276 · Cited by 272 · cited 1×
“In terms of research on device-specific energy savings, there is work in the CPU via dynamic voltage scaling [19, 26, 52, 57, 25, 27, 34, 39, 44, 51, 53, 56, 58, 43, 49], the disk via spindown ( e.g. , [31, 15, 66, 3, 42]), and on the memory or network [13, 40, 10, 36, 69, 68, 7, 8, 12, 37, 62, 38].”
BackgroundHard real-time scheduling for low-energy using stochastic data and DVS processors
Gruian, F. (2001) · Proceedings of the 2001 international symposium on Low power electronics and design - ISLPED '01 · doi:10.1145/383082.383092 · Cited by 245 · cited 1×
“In terms of research on device-specific energy savings, there is work in the CPU via dynamic voltage scaling [19, 26, 52, 57, 25, 27, 34, 39, 44, 51, 53, 56, 58, 43, 49], the disk via spindown ( e.g. , [31, 15, 66, 3, 42]), and on the memory or network [13, 40, 10, 36, 69, 68, 7, 8, 12, 37, 62, 38].”
BackgroundEnergy conservation policies for web servers
Elnozahy, M., Kistler, M., & Rajamony, R. (2003) · USENIX Symposium on Internet Technologies and Systems · Cited by 228
Reducing Energy Consumption of Disk Storage Using Power-Aware Cache Management
Zhu, Q., David, F. M., Devaraj, C. F., Li, Z., Zhou, Y., & Cao, P. (2005) · 10th International Symposium on High Performance Computer Architecture (HPCA'04) · doi:10.1109/hpca.2004.10022 · Cited by 219 · cited 1×
“Another approach is to improve cache performance—if many consecutive disk accesses are cache hits, the disk can be profitably powered down until there is a miss; this is the approach taken by [ 73 ].”
BackgroundPower-aware QoS management in Web servers
Sharma, V., Thomas, A., Abdelzaher, T., Skadron, K., & Lu, Z. (2004) · Proceedings. 2003 International Symposium on System-on-Chip (IEEE Cat. No.03EX748) · doi:10.1109/real.2003.1253254 · Cited by 216 · cited 2×
“The work in [ 61 ] applies real-time techniques to web servers in order to conserve energy while maintaining quality of service.”
MethodA dynamic disk spin-down technique for mobile computing
Helmbold, D. P., Long, D. D. E., & Sherrod, B. (1996) · Proceedings of the 2nd annual international conference on Mobile computing and networking · doi:10.1145/236387.236423 · Cited by 213 · cited 1×
“In terms of research on device-specific energy savings, there is work in the CPU via dynamic voltage scaling [19, 26, 52, 57, 25, 27, 34, 39, 44, 51, 53, 56, 58, 43, 49], the disk via spindown ( e.g. , [31, 15, 66, 3, 42]), and on the memory or network [13, 40, 10, 36, 69, 68, 7, 8, 12, 37, 62, 38].”
BackgroundEnergy efficient fixed-priority scheduling for real-time systems on variable voltage processors
Quan, G., & Hu, X. S. (2001) · ACM/IEEE Design Automation Conference (DAC) · doi:10.1145/378239.379074 · Cited by 213 · cited 1×
“In terms of research on device-specific energy savings, there is work in the CPU via dynamic voltage scaling [19, 26, 52, 57, 25, 27, 34, 39, 44, 51, 53, 56, 58 , 43, 49], the disk via spindown (e.g., [31, 15, 66, 3, 42]), and on the memory or network [13, 40, 10, 36, 69, 68, 7, 8, 12, 37, 62, 38].”
BackgroundEvery joule is precious: the case for revisiting operating system design for energy efficiency
Vahdat, A. M., Lebeck, A. R., & Ellis, C. S. (2000) · ACM SIGOPS European Workshop · doi:10.1145/566726.566735 · Cited by 168 · cited 1×
“At the system level, there is work in trying to make the OS energy-aware through making energy a first class resource [63, 16, 11].”
BackgroundScheduler-based DRAM energy management
Delaluz, V., Sivasubramaniam, A., Kandemir, M., Vijaykrishnan, N., & Irwin, M. J. (2002) · Proceedings - ACM IEEE Design Automation Conference · doi:10.1145/513918.514095 · Cited by 139 · cited 1×
“In terms of research on device-specific energy savings, there is work in the CPU via dynamic voltage scaling [19, 26, 52, 57, 25, 27, 34, 39, 44, 51, 53, 56, 58, 43, 49], the disk via spindown ( e.g. , [31, 15, 66, 3, 42]), and on the memory or network [13, 40, 10, 36, 69, 68, 7, 8, 12, 37, 62, 38].”
BackgroundApplication-specific Network Management for Energy-Aware Streaming of Popular Multimedia Formats
Chandra, S., & Vahdat, A. M. (2002) · Cited by 138
Architectural requirements and scalability of the NAS parallel benchmarks
Wong, F. C., Martin, R. P., Arpaci-Dusseau, R. H., & Culler, D. (1999) · ACM/IEEE Conference on Supercomputing (SC) · doi:10.1145/331532.331573 · Cited by 132 · cited 1×
“…/* Tuple (energy,time) for current G (initially the baseline) */ given ≺ /* A user-defined relationship that defines total order of T */ /* Invoke the function to start method that produces final solution, G are well-written ( e.g. , see [67])—so that they are not unrealistically communication bound.”
BackgroundOperating-system directed power reduction
Lu, Y.-H., Benini, L., & Micheli, G. D. (2000) · International Symposium on Low Power Electronics and Design (ISLPED) · doi:10.1109/lpe.2000.155250 · Cited by 124 · cited 1×
“One important avenue of application-level research on mobile devices focuses on collaboration with the OS [46, 65, 70 , 71, 72, 21, 20, 2]. Such application-related approaches are complementary to our approach.”
BackgroundExploring the Energy-Time Tradeoff in MPI Programs on a Power-Scalable Cluster
Freeh, V. W., Pan, F., Kappiah, N., Lowenthal, D. K., & Springer, R. (2005) · IEEE International Parallel and Distributed Processing Symposium (IPDPS) · doi:10.1109/ipdps.2005.214 · Cited by 122
Self-citationEnergy priority scheduling for variable voltage processors
Pouwelse, J. A., Langendoen, K. G., & Sips, H. J. (2001) · International Symposium on Low Power Electronics and Design (ISLPED) · doi:10.1145/383082.383089 · Cited by 110 · cited 1×
“In terms of research on device-specific energy savings, there is work in the CPU via dynamic voltage scaling [19, 26, 52, 57, 25, 27, 34, 39, 44, 51, 53, 56, 58, 43, 49], the disk via spindown ( e.g. , [31, 15, 66, 3, 42]), and on the memory or network [13, 40, 10, 36, 69, 68, 7, 8, 12, 37, 62, 38].”
BackgroundReducing disk power consumption in servers with DRPM
Gurumurthi, S., Sivasubramaniam, A., Kandemir, M., & Franke, H. (2003) · Computer · doi:10.1109/mc.2003.1250884 · Cited by 103 · cited 1×
“DRPM is a scheme that dynamically modulates the speed of the disk to save energy [28, 29].”
BackgroundApplication transformations for energy and performance-aware device management
Heath, T., Pinheiro, E., Hom, J., et al. (2002) · doi:10.5555/645989.674304 · Cited by 68
Power-aware communication for mobile computers
Kravets, R. H., Schwan, K., & Calvert, K. L. (2003) · IEEE International Workshop on Mobile Multimedia Communications (MoMuC) · doi:10.1109/momuc.1999.819474 · Cited by 51
Program Counter Based Techniques for Dynamic Power Management
Gniady, C., Hu, Y., & Lu, Y.-H. (2005) · IEEE International Symposium on High-Performance Computer Architecture (HPCA) · doi:10.1109/hpca.2004.10021 · Cited by 46 · cited 2×
“Note that our inclusion of the program counter bears some resemblance to existing program counter based techniques [ 23 ], though that work is aimed solely at saving energy in the disk.”
MethodResult
Cited by
A Power-Aware Run-Time System for High-Performance Computing
Hsu, C.-H., & Feng, W.-C. (2005) · ACM/IEEE SC 2005 Conference (SC'05) · doi:10.1109/sc.2005.3 · Cited by 402
PowerPack: Energy Profiling and Analysis of High-Performance Systems and Applications
Ge, R., Feng, X., Song, S., Chang, H.-C., Li, D., & Cameron, K. W. (2010) · IEEE Transactions on Parallel and Distributed Systems · doi:10.1109/tpds.2009.76 · Cited by 382
Collecting Performance Data with PAPI-C
Terpstra, D., Jagode, H., You, H., & Dongarra, J. (2010) · Tools for High Performance Computing 2009 · doi:10.1007/978-3-642-11261-4_11 · Cited by 338
Ge, R., Feng, X., & Cameron, K. W. (2005) · ACM/IEEE SC 2005 Conference (SC'05) · doi:10.1109/sc.2005.57 · Cited by 315
Power-aware scheduling of virtual machines in DVFS-enabled clusters
von Laszewski, G., Wang, L., Younge, A. J., & He, X. (2009) · 2009 IEEE International Conference on Cluster Computing and Workshops · doi:10.1109/clustr.2009.5289182 · Cited by 285
Metadata
- Authors
- Freeh, V. W., & Lowenthal, D. K.
- Venue
- Proceedings of the tenth ACM SIGPLAN symposium on Principles and practice of parallel programming
- Publisher
- ACM
- Published
- 2005-06-15
- Pages
- 164-173
- OpenAlex
- W2031136586
- Cited by
- 208
- References
- 38
- FWCI
- 9.29
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.