A performance-conserving approach for reducing peak power consumption in server systems
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The combination of increasing component power consumption, a desire for denser systems, and the required performance growth in the face of technology-scaling issues are posing enormous challenges for powering and cooling of server systems. The challenges are directly linked to the peak power consumption of servers.Our solution, Power Shifting, reduces the peak power consumption of servers minimizing the impact on performance. We reduce peak power consumption by using workload-guided dynamic allocation of power among components incorporating real-time performance feedback, activity-related power estimation techniques, and performance-sensitive activity-regulation mechanisms to enforce power budgets.We apply our techniques to a computer system with a single processor and memory. Power shifting adds a system power manager with a dynamic, global view of the system's power consumption to continuously re-budget the available power amongst the two components. Our contributions include:• Demonstration of the greater effectiveness of dynamic power allocation over static budgeting,• Evaluation of different power shifting policies,• Analysis of system and workload factors critical to successful power shifting, and• Proposal of performance-sensitive power budget enforcement mechanisms that ensure system reliability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Energy management for commercial servers
Lefurgy, C., Rajamani, K., Rawson, F., Felter, W., Kistler, M., & Keller, T. W. (2003) · Computer · doi:10.1109/mc.2003.1250880 · Cited by 473 · cited 1×
“We focus on these two components as they are the most significant consumers of power in server computing systems, with memory often outstripping the processors in a fully-configured system[ 5 ].”
BackgroundSelf-citationECOSystem: managing energy as a first class operating system resource
Zeng, H., Ellis, C. S., Lebeck, A. R., & Vahdat, A. (2002) · Proceedings of the 10th international conference on Architectural support for programming languages and operating systems · doi:10.1145/605397.605411 · Cited by 375
Energy is just another resource: energy accounting and energy pricing in the Nemesis OS
Neugebauer, R., & McAuley, D. (2005) · Workshop on Hot Topics in Operating Systems · doi:10.1109/hotos.2001.990063 · Cited by 100
Cited by
Power provisioning for a warehouse-sized computer
Fan, X., Weber, W.-D., & Barroso, L. A. (2007) · Proceedings of the 34th annual international symposium on Computer architecture · doi:10.1145/1250662.1250665 · Cited by 1,797
Power provisioning for a warehouse-sized computer
Fan, X., Weber, W.-D., & Barroso, L. A. (2007) · ACM SIGARCH Computer Architecture News · doi:10.1145/1273440.1250665 · Cited by 662
pMapper: Power and Migration Cost Aware Application Placement in Virtualized Systems
Verma, A., Ahuja, P., & Neogi, A. (2008) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-89856-6_13 · Cited by 649
No "power" struggles: coordinated multi-level power management for the data center
Raghavendra, R., Ranganathan, P., Talwar, V., Wang, Z., & Zhu, X. (2008) · Proceedings of the 13th international conference on Architectural support for programming languages and operating systems · doi:10.1145/1346281.1346289 · Cited by 619
RAPL: memory power estimation and capping
David, H., Gorbatov, E., Hanebutte, U. R., Khanna, R., & Le, C. (2010) · Proceedings of the 16th ACM/IEEE international symposium on Low power electronics and design · doi:10.1145/1840845.1840883 · Cited by 597
Optimal power allocation in server farms
Gandhi, A., Harchol-Balter, M., Das, R., & Lefurgy, C. (2009) · Proceedings of the eleventh international joint conference on Measurement and modeling of computer systems · doi:10.1145/1555349.1555368 · Cited by 457
GreenCloud: a new architecture for green data center
Liu, L., Wang, H., Liu, X., Jin, X., He, W. B., Wang, Q. B., & Chen, Y. (2009) · Proceedings of the 6th international conference industry session on Autonomic computing and communications industry session · doi:10.1145/1555312.1555319 · Cited by 371
Ensemble-level Power Management for Dense Blade Servers
Ranganathan, P., Leech, P., Irwin, D., & Chase, J. (2006) · ACM SIGARCH Computer Architecture News · doi:10.1145/1150019.1136492 · Cited by 357
Memory power management via dynamic voltage/frequency scaling
David, H., Fallin, C., Gorbatov, E., Hanebutte, U. R., & Mutlu, O. (2011) · Proceedings of the 8th ACM international conference on Autonomic computing · doi:10.1145/1998582.1998590 · Cited by 334
Mistral: Dynamically Managing Power, Performance, and Adaptation Cost in Cloud Infrastructures
Jung, G., Hiltunen, M. A., Joshi, K. R., Schlichting, R. D., & Pu, C. (2010) · 2010 IEEE 30th International Conference on Distributed Computing Systems · doi:10.1109/icdcs.2010.88 · Cited by 299
Lefurgy, C., Wang, X., & Ware, M. (2007) · Fourth International Conference on Autonomic Computing (ICAC'07) · doi:10.1109/icac.2007.35 · Cited by 292
Benefits and limitations of tapping into stored energy for datacenters
Govindan, S., Sivasubramaniam, A., & Urgaonkar, B. (2011) · Proceedings of the 38th annual international symposium on Computer architecture · doi:10.1145/2000064.2000105 · Cited by 223
“The impact of peak power on provisioning has been looked at from both provisioning for IT equipment - maximizing the utilization of the datacenter power infrastructure [12,13,19,29,36] as well as the cooling cost viewpoint [2,42].”
BackgroundMercury and freon: temperature emulation and management for server systems
Heath, T., Centeno, A. P., George, P., Ramos, L., Jaluria, Y., & Bianchini, R. (2006) · Proceedings of the 12th international conference on Architectural support for programming languages and operating systems · doi:10.1145/1168857.1168872 · Cited by 199
Power capping: a prelude to power shifting
Lefurgy, C., Wang, X., & Ware, M. (2008) · Cluster Computing · doi:10.1007/s10586-007-0045-4 · Cited by 188
“[18] use open-loop control to shift power between processor and memory components to maintain a server power budget.”
BackgroundOn Architecture Design, Congestion Notification, TCP Incast and Power Consumption in Data Centers
Zhang, Y., & Ansari, N. (2013) · IEEE Communications Surveys & Tutorials · doi:10.1109/surv.2011.122211.00017 · Cited by 165
Raghavendra (2008) · doi:10.1145/1353534.1346289 · Cited by 134
Autonomic Power & Performance Management for Large-Scale Data Centers
Khargharia, B., Hariri, S., Szidarovszky, F., Houri, M., El-Rewini, H., Khan, S. U., Ahmad, I., & Yousif, M. S. (2007) · 2007 IEEE International Parallel and Distributed Processing Symposium · doi:10.1109/ipdps.2007.370510 · Cited by 60
Metadata
- Authors
- Felter, W., Rajamani, K., Keller, T., & Rusu, C.
- Venue
- Proceedings of the 19th annual international conference on Supercomputing
- Publisher
- ACM
- Published
- 2005-06-20
- Pages
- 293-302
- OpenAlex
- W2109066397
- Cited by
- 196
- References
- 3
- FWCI
- 10.71
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.