The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Target size study for one-handed thumb use on small touchscreen devices
Abstract
This paper describes a two-phase study conducted to determine optimal target sizes for one-handed thumb use of mobile handheld devices equipped with a touch-sensitive screen. Similar studies have provided recommendations for target sizes when using a mobile device with two hands plus a stylus, and interacting with a desktop-sized display with an index finger, but never for thumbs when holding a small device in a single hand. The first phase explored the required target size for single-target (discrete) pointing tasks, such as activating buttons, radio buttons or checkboxes. The second phase investigated optimal sizes for widgets used for tasks that involve a sequence of taps (serial), such as text entry. Since holding a device in one hand constrains thumb movement, we varied target positions to determine if performance depended on screen location. The results showed that while speed generally improved as targets grew, there were no significant differences in error rate between target sizes =9.6 mm in discrete tasks and targets =7.7 mm in serial tasks. Along with subjective ratings and the findings on hit response variability, we found that target size of 9.2 mm for discrete tasks and targets of 9.6 mm for serial tasks should be sufficiently large for one-handed thumb use on touchscreen-based handhelds without degrading performance and preference.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The information capacity of the human motor system in controlling the amplitude of movement.
Fitts, P. M. (1954) · Journal of Experimental Psychology · doi:10.1037/h0055392 · Cited by 6,466 · cited 1×
“While these results seem contradictory, they are both consistent with Fitts’ model for motor movement [ 4 ], which defines movement time (MT) with respect to the distance to (or amplitude, A) and size of (W) the target as:”
Result
Cited by
Kane, S. K., Bigham, J. P., & Wobbrock, J. O. (2008) · Proceedings of the 10th International ACM SIGACCESS Conference on Computers and Accessibility · doi:10.1145/1414471.1414487 · Cited by 374
Age-related differences in performance with touchscreens compared to traditional mouse input
Findlater, L., Froehlich, J. E., Fattal, K., Wobbrock, J. O., & Dastyar, T. (2013) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/2470654.2470703 · Cited by 172
SemFeel: a user interface with semantic tactile feedback for mobile touch-screen devices
Yatani, K., & Truong, K. N. (2009) · Proceedings of the 22nd annual ACM symposium on User interface software and technology · doi:10.1145/1622176.1622198 · Cited by 164
Investigating selection and reading performance on a mobile phone while walking
Schildbach, B., & Rukzio, E. (2010) · Proceedings of the 12th international conference on Human computer interaction with mobile devices and services · doi:10.1145/1851600.1851619 · Cited by 154
Bailly, G., Lecolinet, E., & Nigay, L. (2017) · ACM Computing Surveys · doi:10.1145/3002171 · Cited by 139
Metadata
- Authors
- Parhi, P., Karlson, A. K., & Bederson, B. B.
- Venue
- Proceedings of the 8th conference on Human-computer interaction with mobile devices and services
- Publisher
- ACM
- Published
- 2006-09-12
- Pages
- 203-210
- OpenAlex
- W2036530198
- Cited by
- 352
- References
- 1
- FWCI
- 10.75
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Target size study for one-handed thumb use on small touchscreen devices. https://app.cochat.ai/papers/10.1145/1152215.1152260
- The paper
- Parhi, P., Karlson, A. K., & Bederson, B. B. (2006). Target size study for one-handed thumb use on small touchscreen devices. Proceedings of the 8th conference on Human-computer interaction with mobile devices and services. https://doi.org/10.1145/1152215.1152260
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.