Joint optimization of idle and cooling power in data centers while maintaining response time

Ahmad, Faraz, Vijaykumar, T. N.·2010·ACM SIGPLAN Notices

Abstract

Server power and cooling power amount to a significant fraction of modern data centers' recurring costs. While data centers provision enough servers to guarantee response times under the maximum loading, data centers operate under much less loading most of the times (e.g., 30-70% of the maximum loading). Previous server-power proposals exploit this under-utilization to reduce the server idle power by keeping active only as many servers as necessary and putting the rest into low-power standby modes. However, these proposals incur higher cooling power due to hot spots created by concentrating the data center loading on fewer active servers, or degrade response times due to standby-to-active transition delays, or both. Other proposals optimize the cooling power but incur considerable idle power. To address the first issue of power, we propose PowerTrade , which trades-off idle power and cooling power for each other, thereby reducing the total power. To address the second issue of response time, we propose SurgeGuard to overprovision the number of active servers beyond that needed by the current loading so as to absorb future increases in the loading. SurgeGuard is a two-tier scheme which uses well-known over-provisioning at coarse time granularities (e.g., one hour) to absorb the common, smooth increases in the loading, and a novel fine-grain replenishment of the over-provisioned reserves at fine time granularities (e.g., five minutes) to handle the uncommon, abrupt loading surges. Using real-world traces, we show that combining PowerTrade and SurgeGuard reduces total power by 30% compared to previous low-power schemes while maintaining response times within 1.7%.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1145/1735971.1736048

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 188

Metadata

Authors
Ahmad, F., & Vijaykumar, T. N.
Venue
ACM SIGPLAN Notices
Published
2010-03-05
Volume
45
Issue
3
Pages
243-256
ISSN
  • 0362-1340 (ISSN-L)
  • 1558-1160
OpenAlex
W2097964682
Cited by
188
References
0
FWCI
67.77
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Joint optimization of idle and cooling power in data centers while maintaining response time. https://app.cochat.ai/papers/10.1145/1735971.1736048
The paper
Ahmad, F., & Vijaykumar, T. N. (2010). Joint optimization of idle and cooling power in data centers while maintaining response time. ACM SIGPLAN Notices. https://doi.org/10.1145/1735971.1736048

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.