The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Assessing mobile touch interfaces for tetraplegics
Abstract
Mobile touch-screen interfaces and tetraplegic people have a controversial connection. While users with residual capacities in their upper extremities could benefit immensely from a device which does not require strength to operate, the precision needed to effectively select a target bars these people access to countless communication, leisure and productivity opportunities. Insightful projects attempted to bridge this gap via either special hardware or particular interface tweaks. Still, we need further insight into the challenges and the frontiers separating failure from success for such applications to take hold. This paper discusses an evaluation conducted with 15 tetraplegic people to learn the limits to their performance within a comprehensive set of interaction methods. We then present the results concerning a particular interaction technique: Tapping. Results show that performance varies across different areas of the screen whose distribution changes with target size.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assistive Technologies: Principles and Practice
Cook, A. M., & Polgar, J. M. (1995) · Cited by 1,011
EdgeWrite: a stylus-based text entry method designed for high accuracy and stability of motion
Wobbrock, J. O., Myers, B. A., & Kembel, J. A. (2003) · Proceedings of the 16th annual ACM symposium on User interface software and technology · doi:10.1145/964696.964703 · Cited by 355
Target size study for one-handed thumb use on small touchscreen devices
Parhi, P., Karlson, A. K., & Bederson, B. B. (2006) · Proceedings of the 8th conference on Human-computer interaction with mobile devices and services · doi:10.1145/1152215.1152260 · Cited by 352
Mobile text entry: relationship between walking speed and text input task difficulty
Mizobuchi, S., Chignell, M., & Newton, D. C. (2005) · International Conference on Human-Computer Interaction with Mobile Devices and Services (MobileHCI) · doi:10.1145/1085777.1085798 · Cited by 133 · cited 1×
“Indeed, this is true for able-bodied users in static environments and also for situationally impaired subjects [8,4].”
BackgroundEvaluating one handed thumb tapping on mobile touchscreen devices
Perry, K. B., & Hourcade, J. P. (2008) · Graphics Interface · Cited by 109
Touch key design for target selection on a mobile phone
Park, Y. S., Han, S. H., Park, J., & Cho, Y. (2008) · International Conference on Human-Computer Interaction with Mobile Devices and Services (MobileHCI) · doi:10.1145/1409240.1409304 · Cited by 93
Using handhelds to help people with motor impairments
Myers, B. A., Wobbrock, J. O., Yang, S., Yeung, B., Nichols, J. W., & Miller, R. C. (2002) · International ACM SIGACCESS Conference on Computers and Accessibility (ASSETS) · doi:10.1145/638249.638266 · Cited by 81
Barrier pointing: using physical edges to assist target acquisition on mobile device touch screens
Froehlich, J., Wobbrock, J. O., & Kane, S. K. (2007) · Proceedings of the 9th international ACM SIGACCESS conference on Computers and accessibility · doi:10.1145/1296843.1296849 · Cited by 74
Research works printed but not linked: 1
- Sears , A. , When Computers Fade. Pervasive Computing and Situationally-Induced Impairments and Disabilities , pp. 1298 -- 1302 . Lawrence Erlbaum Associates , 2003 . Sears, A., et al. When Computers Fade. Pervasive Computing and Situationally-Induced Impairments and Disabilities, pp. 1298--1302. Lawrence Erlbaum Associates, 2003.
Cited by
Usability of mobile applications: literature review and rationale for a new usability model
Harrison, R., Flood, D., & Duce, D. (2013) · Journal of Interaction Science · doi:10.1186/2194-0827-1-1 · Cited by 736
Naftali, M., & Findlater, L. (2014) · Proceedings of the 16th international ACM SIGACCESS conference on Computers & accessibility - ASSETS '14 · doi:10.1145/2661334.2661372 · Cited by 105
“[13] measured the accuracy of tapping, crossing, exiting and directional gesturing operations with users with tetraplegia, finding that targets located at the bottom of the screen and next to the preferred hand were the easiest to select.”
BackgroundSmart Touch: Improving Touch Accuracy for People with Motor Impairments with Template Matching
Mott, M. E., Vatavu, R.-D., Kane, S. K., & Wobbrock, J. O. (2016) · Proceedings of the 2016 CHI Conference on Human Factors in Computing Systems · doi:10.1145/2858036.2858390 · Cited by 68
“[16,17] explored how different interaction techniques and target properties impact the ability of users to acquire targets.”
BackgroundInfluentialEvaluating swabbing: a touchscreen input method for elderly users with tremor
Wacharamanotham, C., Hurtmanns, J., Mertens, A., Kronenbuerger, M., Schlick, C. M., & Borchers, J. (2011) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/1978942.1979031 · Cited by 81
“The targets were spread evenly across the screen because previous research has shown that finger selection accuracy can differ for different areas [5].”
BackgroundTowards accessible touch interfaces
Guerreiro, T., Nicolau, H., Jorge, J., & Gonçalves, D. (2010) · Proceedings of the 12th international ACM SIGACCESS conference on Computers and accessibility · doi:10.1145/1878803.1878809 · Cited by 66
“However, no correlations between participants’ characteristics and task performance were found [4].”
BackgroundSelf-citation
Metadata
- Authors
- Guerreiro, T. J. V., Nicolau, H., Jorge, J., & Gonçalves, D.
- Affiliations
- Instituto de Engenharia de Sistemas e Computadores Investigação e Desenvolvimento (PT)
- Venue
- Proceedings of the 12th international conference on Human computer interaction with mobile devices and services
- Publisher
- ACM
- Published
- 2010-09-07
- Pages
- 31-34
- OpenAlex
- W1978118359
- Semantic Scholar
- 0e8e861f1dfcd3acf1f0ba7740033a4c7f29fa60
- Cited by
- 34
- References
- 8
- Citations by year
- 2024: 2 · 2023: 2 · 2022: 2 · 2021: 2 · 2019: 2 · 2018: 4 · 2016: 4 · 2015: 2 · 2014: 4 · 2013: 5 · 2012: 2
- FWCI
- 2.45
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- International Conference on Human-Computer Interaction with Mobile Devices and Services (MobileHCI) (publishedVersion)
- Funders
- Fundação para a Ciência e a Tecnologia
- Topics
- Physical Sciences › Computer Science › Human-Computer Interaction › Interactive and Immersive Displays
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Health Sciences › Health Professions › Occupational Therapy › Assistive Technology in Communication and Mobility
- Keywords
- tetraplegia, touch screen interface, mobile devices, assistive technology, target size, interaction performance, upper limb impairment, accessibility evaluation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessing mobile touch interfaces for tetraplegics. https://app.cochat.ai/papers/10.1145/1851600.1851608
- The paper
- Guerreiro, T. J. V., Nicolau, H., Jorge, J., & Gonçalves, D. (2010). Assessing mobile touch interfaces for tetraplegics. Proceedings of the 12th international conference on Human computer interaction with mobile devices and services. https://doi.org/10.1145/1851600.1851608
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.