Occupancy-driven energy management for smart building automation
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Buildings are among the largest consumers of electricity in the US. A significant portion of this energy use in buildings can be attributed to HVAC systems used to maintain comfort for occupants. In most cases these building HVAC systems run on fixed schedules and do not employ any fine grained control based on detailed occupancy information. In this paper we present the design and implementation of a presence sensor platform that can be used for accurate occupancy detection at the level of individual offices. Our presence sensor is low-cost, wireless, and incrementally deployable within existing buildings. Using a pilot deployment of our system across ten offices over a two week period we identify significant opportunities for energy savings due to periods of vacancy. Our energy measurements show that our presence node has an estimated battery lifetime of over five years, while detecting occupancy accurately. Furthermore, using a building simulation framework and the occupancy information from our testbed, we show potential energy savings from 10% to 15% using our system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Instrumenting the world with wireless sensor networks
Estrin, D., Girod, L., Pottie, G., & Srivastava, M. (2002) · 2001 IEEE International Conference on Acoustics, Speech, and Signal Processing. Proceedings (Cat. No.01CH37221) · doi:10.1109/icassp.2001.940390 · Cited by 1,164
Somniloquy: Augmenting Network Interfaces to Reduce PC Energy Usage
Agarwal, Y., Hodges, S. E., Chandra, R., Scott, J., Bahl, P., & Gupta, R. K. (2009) · Cited by 228
Self-citationEvaluation of energy-efficiency in lighting systems using sensor networks
Delaney, D. T., O’Hare, G. M. P., & Ruzzelli, A. G. (2009) · ACM International Conference on Systems for Energy-Efficient Buildings, Cities, and Transportation (BuildSys) · doi:10.1145/1810279.1810293 · Cited by 142
CO 2-Based Occupancy Detection for On-Line Outdoor Air Flow Control
Wang, S., & Jin, X. (1998) · Indoor and Built Environment · doi:10.1159/000024577 · Cited by 136
Kleissl, J. P., & Agarwal, Y. (2010) · Proceedings - ACM IEEE Design Automation Conference · doi:10.1145/1837274.1837464 · Cited by 122
Self-citationThe self-programming thermostat: optimizing setback schedules based on home occupancy patterns
Gao, G., & Whitehouse, K. (2009) · ACM International Conference on Systems for Energy-Efficient Buildings, Cities, and Transportation (BuildSys) · doi:10.1145/1810279.1810294 · Cited by 112
Home energy saving through a user profiling system based on wireless sensors
Barbato, A., Borsani, L., Capone, A., & Melzi, S. (2009) · ACM International Conference on Systems for Energy-Efficient Buildings, Cities, and Transportation (BuildSys) · doi:10.1145/1810279.1810291 · Cited by 97
Sonar-based measurement of user presence and attention
Tarzia, S. P., Dick, R. P., Dinda, P. A., & Memik, G. (2009) · ACM International Joint Conference on Pervasive and Ubiquitous Computing (UbiComp) · doi:10.1145/1620545.1620559 · Cited by 87
Localized air-conditioning with occupancy control in an open office
Lo, L. J., & Novoselac, A. (2010) · Energy and Buildings · doi:10.1016/j.enbuild.2010.02.003 · Cited by 79
Lightweight People Counting and Localizing for Easily Deployable Indoors WSNs
Teixeira, T., & Savvides, A. (2008) · IEEE Journal of Selected Topics in Signal Processing · doi:10.1109/jstsp.2008.2001426 · Cited by 36
Cited by
Energy intelligent buildings based on user activity: A survey
Nguyen, T. A., & Aiello, M. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2012.09.005 · Cited by 714
Candanedo, L. M., & Feldheim, V. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2015.11.071 · Cited by 586
Coordinating occupant behavior for building energy and comfort management using multi-agent systems
Klein, L., Kwak, J.-Y., Kavulya, G., Jazizadeh, F., Becerik-Gerber, B., Varakantham, P., & Tambe, M. (2012) · Automation in Construction · doi:10.1016/j.autcon.2011.11.012 · Cited by 367
A review of smart building sensing system for better indoor environment control
Dong, B., Prakash, V., Feng, F., & O'Neill, Z. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2019.06.025 · Cited by 360
Measuring and monitoring occupancy with an RFID based system for demand-driven HVAC operations
Li, N., Calis, G., & Becerik-Gerber, B. (2012) · Automation in Construction · doi:10.1016/j.autcon.2012.02.013 · Cited by 330
Buckman, A. H., Mayfield, M., & B.M. Beck, S. (2014) · Smart and Sustainable Built Environment · doi:10.1108/sasbe-01-2014-0003 · Cited by 318
Balaji, B., Xu, J., Nwokafor, A., Gupta, R., & Agarwal, Y. (2013) · Proceedings of the 11th ACM Conference on Embedded Networked Sensor Systems · doi:10.1145/2517351.2517370 · Cited by 318
Self-citationBuilding occupancy estimation and detection: A review
Chen, Z., Jiang, C., & Xie, L. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.03.084 · Cited by 280
Jung, W., & Jazizadeh, F. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.01.070 · Cited by 276
Occupancy Estimation Using Only WiFi Power Measurements
Depatla, S., Muralidharan, A., & Mostofi, Y. (2015) · IEEE Journal on Selected Areas in Communications · doi:10.1109/jsac.2015.2430272 · Cited by 267
Handling model uncertainty in model predictive control for energy efficient buildings
Maasoumy, M., Razmara, M., Shahbakhti, M., & Vincentelli, A. S. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.03.057 · Cited by 254
Occupancy-based HVAC control systems in buildings: A state-of-the-art review
Esrafilian-Najafabadi, M., & Haghighat, F. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.107810 · Cited by 218
Non-Intrusive Occupancy Monitoring using Smart Meters
Chen, D., Barker, S., Subbaswamy, A., Irwin, D., & Shenoy, P. (2013) · Proceedings of the 5th ACM Workshop on Embedded Systems For Energy-Efficient Buildings · doi:10.1145/2528282.2528294 · Cited by 180
“Thus, many systems monitor occupancy by strategically deploying one or more environmental sensors, including motion [2, 24, 26], door [1], acoustic [8, 17], camera [14, 15, 20], contact [26, 29], and CO2 [10, 31] sensors.”
BackgroundKnown unknowns: Indirect energy effects of information and communication technology
Horner, N. C., Shehabi, A., & Azevedo, I. L. (2016) · Environmental Research Letters · doi:10.1088/1748-9326/11/10/103001 · Cited by 177
Indoor air quality and energy management through real-time sensing in commercial buildings
Kumar, P., Martani, C., Morawska, L., Norford, L., Choudhary, R., Bell, M., & Leach, M. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2015.11.037 · Cited by 165
“The state–of–the–art In line with the needs for SES, the development of end–user interaction tools, as well as the analysis of the energy efficiency of the built environment has received considerable attention in recent years [49-51].”
BackgroundSurvey of Non-Image-Based Approaches for Counting People
Kouyoumdjieva, S. T., Danielis, P., & Karlsson, G. (2020) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2019.2902824 · Cited by 61
“One of the main application areas for occupancy detection solutions is thus in the context of smart buildings automation, often for optimizing energy consumption in the heating, ventilation and air conditioning (HVAC) system [9].”
BackgroundDesign Patterns for Cyber-Physical Systems of Buildings
Kychkin, A., Deryabin, A., Vikentyeva, O., & Shestakova, L. (2021) · Lecture Notes in Information Systems and Organisation · doi:10.1007/978-3-030-71397-3_6
Metadata
- Authors
- Agarwal, Y., Balaji, B., Gupta, R., Lyles, J., Wei, M., & Weng, T.
- Venue
- Proceedings of the 2nd ACM Workshop on Embedded Sensing Systems for Energy-Efficiency in Building
- Publisher
- ACM
- Published
- 2010-11-02
- Pages
- 1-6
- OpenAlex
- W1972440681
- Cited by
- 570
- References
- 10
- FWCI
- 71.98
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.