The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
The light field stereoscope: immersive computer graphics via factored near-eye light field displays with focus cues
Abstract
Over the last few years, virtual reality (VR) has re-emerged as a technology that is now feasible at low cost via inexpensive cellphone components. In particular, advances of high-resolution micro displays, low-latency orientation trackers, and modern GPUs facilitate immersive experiences at low cost. One of the remaining challenges to further improve visual comfort in VR experiences is the vergence-accommodation conflict inherent to all stereoscopic displays. Accurate reproduction of all depth cues is crucial for visual comfort. By combining well-known stereoscopic display principles with emerging factored light field technology, we present the first wearable VR display supporting high image resolution as well as focus cues. A light field is presented to each eye, which provides more natural viewing experiences than conventional near-eye displays. Since the eye box is just slightly larger than the pupil size, rank-1 light field factorizations are sufficient to produce correct or nearly-correct focus cues;no time-multiplexed image display or gaze tracking is required.We analyze lens distortions in 4D light field space and correct them using the afforded high-dimensional image formation. We also demonstrate significant improvements in resolution and retinal blur quality over related near-eye displays. Finally, we analyze diffraction limits of these types of displays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A flexible new technique for camera calibration
Zhang, Z. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.888718 · Cited by 15,004
Levoy, M., & Hanrahan, P. (1996) · Proceedings of the 23rd annual conference on Computer graphics and interactive techniques · doi:10.1145/237170.237199 · Cited by 3,755
A head-mounted three dimensional display
Sutherland, I. E. (1968) · Proceedings of the December 9-11, 1968, fall joint computer conference, part I on - AFIPS '68 (Fall, part I) · doi:10.1145/1476589.1476686 · Cited by 2,065
Wheatstone, C. (1838) · Philosophical Transactions of the Royal Society of London · doi:10.1098/rstl.1838.0019 · Cited by 1,320
Perceiving Layout and Knowing Distances
Cutting, J. E., & Vishton, P. M. (1995) · Perception of Space and Motion · doi:10.1016/b978-012240530-3/50005-5 · Cited by 1,029
Motion and vision II Stabilized spatio-temporal threshold surface
Kelly, D. H. (1979) · Journal of the Optical Society of America · doi:10.1364/josa.69.001340 · Cited by 743
Decentering Distortion of Lenses
Brown, D. C. (1966) · Photogrammetric Engineering & Remote Sensing · Cited by 718
Handbook of Virtual Environments: Design, Implementation, and Applications
(2002) · CRC Press eBooks · doi:10.1201/9780585399102 · Cited by 628
High dynamic range display systems
Seetzen, H., Heidrich, W., Stuerzlinger, W., Ward, G., Whitehead, L., Trentacoste, M., Ghosh, A., & Vorozcovs, A. (2004) · ACM Transactions on Graphics · doi:10.1145/1015706.1015797 · Cited by 562
Virtual Reality Exposure Therapy for Vietnam Veterans With Posttraumatic Stress Disorder
Rothbaum, B. O., Hodges, L. F., Ready, D., Graap, K., & Alarcon, R. D. (2001) · The Journal of Clinical Psychiatry · doi:10.4088/jcp.v62n0808 · Cited by 531
Cakmakci, O., & Rolland, J. (2006) · Journal of Display Technology · doi:10.1109/jdt.2006.879846 · Cited by 507
Compressive light field photography using overcomplete dictionaries and optimized projections
Marwah, K., Wetzstein, G., Bando, Y., & Raskar, R. (2013) · ACM Transactions on Graphics · doi:10.1145/2461912.2461914 · Cited by 398
Self-citationLanman, D., & Luebke, D. (2013) · ACM Transactions on Graphics · doi:10.1145/2508363.2508366 · Cited by 367
Medical Physiology and Biophysics.
(1960) · Annals of Internal Medicine · doi:10.7326/0003-4819-53-4-856 · Cited by 361
A stereo display prototype with multiple focal distances
Akeley, K., Watt, S. J., Girshick, A. R., & Banks, M. S. (2004) · ACM Transactions on Graphics · doi:10.1145/1015706.1015804 · Cited by 315
Focus cues affect perceived depth
Watt, S. J., Akeley, K., Ernst, M. O., & Banks, M. S. (2005) · Journal of Vision · doi:10.1167/5.10.7 · Cited by 297
High-speed switchable lens enables the development of a volumetric stereoscopic display
Love, G. D., Hoffman, D. M., Hands, P. J. W., Gao, J., Kirby, A. K., & Banks, M. S. (2009) · Optics Express · doi:10.1364/oe.17.015716 · Cited by 244
Benton, S. A., & Bove, V. M. (2008) · Wiley eBooks · doi:10.1002/9780470224137 · Cited by 231
Volumetric 3D displays and application infrastructure
Favalora, G. E. (2005) · Computer · doi:10.1109/mc.2005.276 · Cited by 229
A review of head-mounted displays (HMD) technologies and applications for consumer electronics
Kress, B., & Starner, T. (2013) · SPIE Proceedings · doi:10.1117/12.2015654 · Cited by 219
Handbook of Virtual Environments: Design, Implementation, and Applications, Second Edition
(2014) · CRC Press eBooks · doi:10.1201/b17360 · Cited by 192
Lanman, D., & Luebke, D. (2013) · ACM SIGGRAPH 2013 Emerging Technologies · doi:10.1145/2503368.2503379 · Cited by 171
Wetzstein, G., Lanman, D., Heidrich, W., & Raskar, R. (2011) · ACM Transactions on Graphics · doi:10.1145/2010324.1964990 · Cited by 160
Self-citationWetzstein, G., Lanman, D. R., Heidrich, W., & Raskar, R. (2011) · ACM SIGGRAPH Conference (SIGGRAPH) · doi:10.1145/1964921.1964990 · Cited by 152
Self-citationBlur and Disparity Are Complementary Cues to Depth
Held, R. T., Cooper, E. A., & Banks, M. S. (2012) · Current Biology · doi:10.1016/j.cub.2012.01.033 · Cited by 148
MacKenzie, K. J., Hoffman, D. M., & Watt, S. J. (2010) · Journal of Vision · doi:10.1167/10.8.22 · Cited by 124
An optical see-through head mounted display with addressable focal planes
Liu, S., Cheng, D., & Hua, H. (2008) · IEEE/ACM International Symposium on Mixed and Augmented Reality (ISMAR) · doi:10.1109/ismar.2008.4637321 · Cited by 122
Computational augmented reality eyeglasses
Maimone, A., & Fuchs, H. (2013) · Proceedings - International Symposium on Mixed and Augmented Reality, ISMAR · doi:10.1109/ismar.2013.6671761 · Cited by 119
Heide, F., Lanman, D. R., Reddy, D., et al. (2014) · ACM Transactions on Graphics · doi:10.1145/2601097.2601120 · Cited by 49
Focus information is used to interpret binocular images
Hoffman, D. M., & Banks, M. S. (2010) · Journal of Vision · doi:10.1167/10.5.13 · Cited by 47
Clarberg, P., Toth, R., Hasselgren, J., et al. (2014) · ACM Transactions on Graphics · doi:10.1145/2601097.2601214 · Cited by 30
Depth-tuning of occluded moving objects by boundary selection of motion signals
Berzhanskaya, J., Grossberg, S., & Ennio Mingolla, B. (2005) · Journal of Vision · doi:10.1167/5.8.834 · Cited by 14
Cited by
State of the art of virtual reality technology
Anthes, C., Garcia-Hernandez, R. J., Wiedemann, M., & Kranzlmuller, D. (2016) · 2016 IEEE Aerospace Conference · doi:10.1109/aero.2016.7500674 · Cited by 541
Neural holography with camera-in-the-loop training
Peng, Y., Choi, S., Padmanaban, N., & Wetzstein, G. (2020) · ACM Transactions on Graphics · doi:10.1145/3414685.3417802 · Cited by 514
Self-citationVirtual and Augmented Reality on the 5G Highway
Orlosky, J., Kiyokawa, K., & Takemura, H. (2017) · Journal of Information Processing · doi:10.2197/ipsjjip.25.133 · Cited by 107
Metadata
- Authors
- Huang, F.-C., Chen, K., & Wetzstein, G.
- Venue
- ACM Transactions on Graphics
- Published
- 2015-07-27
- Volume
- 34
- Issue
- 4
- Pages
- 1-12
- ISSN
- 0730-0301 (ISSN-L)
- 1557-7368
- OpenAlex
- W2067827172
- Cited by
- 264
- References
- 32
- FWCI
- 50.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.