The DOI matches its Crossref record.
Monitoring vital signs using millimeter wave
Abstract
Continuous monitoring of human's breathing and heart rates is useful in maintaining better health and early detection of many health issues. Designing a technique that can enable contactless and ubiquitous vital sign monitoring is a challenging research problem. This paper presents mmVital, a system that uses 60 GHz millimeter wave (mmWave) signals for vital sign monitoring. We show that the mmWave signals can be directed to human's body and the RSS of the reflections can be analyzed for accurate estimation of breathing and heart rates. We show how the directional beams of mmWave can be used to monitor multiple humans in an indoor space concurrently. mmVital relies on a novel human finding procedure where a human can be located within a room by reflection loss based object/human classification. We evaluate mmVital using a 60 GHz testbed in home and office environment and show that it provides the mean estimation error of 0.43 Bpm (breathing rate) and 2.15 bpm (heart rate). Also, it can locate the human subject with 98.4% accuracy within 100 ms of dwell time on reflection. We also demonstrate that mmVital is effective in monitoring multiple people in parallel and even behind the wall.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Towards Environment Independent Device Free Human Activity Recognition
Jiang, W., Miao, C., Ma, F., Yao, S., Wang, Y., Yuan, Y., Xue, H., Song, C., Ma, X., Koutsonikolas, D., et al. (2018) · Proceedings of the 24th Annual International Conference on Mobile Computing and Networking · doi:10.1145/3241539.3241548 · Cited by 573
PhaseBeat: Exploiting CSI Phase Data for Vital Sign Monitoring with Commodity WiFi Devices
Wang, X., Yang, C., & Mao, S. (2017) · 2017 IEEE 37th International Conference on Distributed Computing Systems (ICDCS) · doi:10.1109/icdcs.2017.206 · Cited by 356
CardiacWave: A mmWave-based Scheme of Non-Contact and High-Definition Heart Activity Computing
Xu, C., Li, H., Li, Z., Zhang, H., Rathore, A. S., Chen, X., Wang, K., Huang, M.-C., & Xu, W. (2021) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3478127 · Cited by 49
Metadata
- Authors
- Yang, Z., Pathak, P. H., Zeng, Y., Liran, X., & Mohapatra, P.
- Venue
- Proceedings of the 17th ACM International Symposium on Mobile Ad Hoc Networking and Computing
- Publisher
- ACM
- Published
- 2016-07-05
- Pages
- 211-220
- OpenAlex
- W2471074815
- Cited by
- 183
- References
- 0
- FWCI
- 20.62
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Monitoring vital signs using millimeter wave. https://app.cochat.ai/papers/10.1145/2942358.2942381
- The paper
- Yang, Z., Pathak, P. H., Zeng, Y., Liran, X., & Mohapatra, P. (2016). Monitoring vital signs using millimeter wave. Proceedings of the 17th ACM International Symposium on Mobile Ad Hoc Networking and Computing. https://doi.org/10.1145/2942358.2942381
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.