C-FMCW Based Contactless Respiration Detection Using Acoustic Signal
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Recent advances in ubiquitous sensing technologies have exploited various approaches to monitoring vital signs. One of the vital signs is human respiration which typically requires reliable monitoring with low error rate in practice. Previous works in respiration monitoring however either incur high cost or suffer from poor error rate. In this paper, we propose a Correlation based Frequency Modulated Continuous Wave method (C-FMCW) which is able to achieve high ranging resolution. Based on C-FMCW, we present the design and implementation of an audio-based highly-accurate system for human respiration monitoring, leveraging on commodity speaker and microphone widely available in home environments. The basic idea behind the audio-based method is that when a user is close to a pair of speaker and microphone, body movement during respiration causes periodic audio signal changes, which can be extracted to obtain the respiration rate. However, several technical challenges exist when applying C-FMCW to detect respiration with commodity acoustic devices. First, the sampling frequency offset between speakers and microphones if not being corrected properly would cause high ranging errors. Second, the uncertain starting time difference between the speaker and microphone varies over time. Moreover, due to multipath effect, weak periodic components due to respiration can easily be overwhelmed by strong static components in practice. To address those challenges, we 1) propose an algorithm to compensate dynamically acoustic signal and counteract the offset between speaker and microphone; 2) co-locate speaker and microphone and use the received signal without reflection (self-interference) as a reference to eliminate the starting time difference; and 3) leverage the periodicity of respiration to extract weak periodic components with autocorrelation. Extensive experimental results show that our system detects respiration in real environments with the median error lower than 0.35 breaths/min, outperforming the state-of-the-arts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smart Homes that Monitor Breathing and Heart Rate
Adib, F., Mao, H., Kabelac, Z., Katabi, D., & Miller, R. C. (2015) · Proceedings of the 33rd Annual ACM Conference on Human Factors in Computing Systems · doi:10.1145/2702123.2702200 · Cited by 916
iSleep: unobtrusive sleep quality monitoring using smartphones
Hao, T., Xing, G., & Zhou, G. (2013) · Proceedings of the 11th ACM Conference on Embedded Networked Sensor Systems · doi:10.1145/2517351.2517359 · Cited by 216 · cited 1×
“iSleep [34] uses microphone on a smartphone to detect the events that are closely related to sleep quality such as body movement and snore.”
MethodAn Ultrasonic Contactless Sensor for Breathing Monitoring
Arlotto, P., Grimaldi, M., Naeck, R., & Ginoux, J.-M. (2014) · Sensors · doi:10.3390/s140815371 · Cited by 102 · cited 7×
“Specifically, the system in [31] monitors the area around nose, while our system monitors the area around chest and abdomen.”
BackgroundMethodInfluential
Cited by
BodyCompass: Monitoring Sleep Posture with Wireless Signals
Yue, S., Yang, Y., Wang, H., Rahul, H., & Katabi, D. (2020) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3397311 · Cited by 112
“3 Radio Specification Weuse a standard FMCW radio similar to the one used in past work [2, 40, 49, 51].”
Metadata
- Authors
- Wang, T., Zhang, D., Zheng, Y., Gu, T., Zhou, X., & Dorizzi, B.
- Venue
- Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Published
- 2018-01-08
- Volume
- 1
- Issue
- 4
- Pages
- 1-20
- ISSN
- 2474-9567 (ISSN-L)
- OpenAlex
- W2783985400
- Cited by
- 180
- References
- 3
- FWCI
- 5.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.