Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 17 of the 19 references it cites were found in a registry or an index.

An Ultrasonic Contactless Sensor for Breathing Monitoring

Open access
Arlotto, Philippe, Grimaldi, Michel, Naeck, Roomila, Ginoux, Jean-Marc · 2014 · Sensors

Abstract

The monitoring of human breathing activity during a long period has multiple fundamental applications in medicine. In breathing sleep disorders such as apnea, the diagnosis is based on events during which the person stops breathing for several periods during sleep. In polysomnography, the standard for sleep disordered breathing analysis, chest movement and airflow are used to monitor the respiratory activity. However, this method has serious drawbacks. Indeed, as the subject should sleep overnight in a laboratory and because of sensors being in direct contact with him, artifacts modifying sleep quality are often observed. This work investigates an analysis of the viability of an ultrasonic device to quantify the breathing activity, without contact and without any perception by the subject. Based on a low power ultrasonic active source and transducer, the device measures the frequency shift produced by the velocity difference between the exhaled air flow and the ambient environment, i.e., the Doppler effect. After acquisition and digitization, a specific signal processing is applied to separate the effects of breath from those due to subject movements from the Doppler signal. The distance between the source and the sensor, about 50 cm, and the use of ultrasound frequency well above audible frequencies, 40 kHz, allow monitoring the breathing activity without any perception by the subject, and therefore without any modification of the sleep quality which is very important for sleep disorders diagnostic applications. This work is patented (patent pending 2013-7-31 number FR.13/57569).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s140815371

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1. Block diagram of the device. The optimum distances and angles between the transmitter/receiver and the subject depend on the angle of the sensors relative to the head, the level of ultrasound source and the characteristics of the receiving system.
Figure 1. Block diagram of the device. The optimum distances and angles between the transmitter/receiver and the subject depend on the angle of the sensors relative to the head, the level of ultrasound source and the characteristics of the receiving system.CC BY · PubMed Central
Figure 2. Block diagram of the receiver system.
Figure 2. Block diagram of the receiver system.CC BY · PubMed Central
Figure 3. Signal visualization during rest and expiration phases. On top (A) a time (vertical) to frequency (horizontal) representation around the incident frequency pick. On bottom (B) the spectrum module during an expiration phase (1) and (C) the spectrum module during a rest phase (2), expressed in decibels.
Figure 3. Signal visualization during rest and expiration phases. On top (A) a time (vertical) to frequency (horizontal) representation around the incident frequency pick. On bottom (B) the spectrum module during an expiration phase (1) and (C) the spectrum module during a rest phase (2), expressed in decibels.CC BY · PubMed Central
Figure 4. Observation angle of the scattered wave.
Figure 4. Observation angle of the scattered wave.CC BY · PubMed Central
Figure 5. Observation angle of the scattered wave. We can see that there is no scattered signal θs = 90° or backscattered signal θs = 180° with a local maximum for θs = 130°.
Figure 5. Observation angle of the scattered wave. We can see that there is no scattered signal θs = 90° or backscattered signal θs = 180° with a local maximum for θs = 130°.CC BY · PubMed Central
Figure 6. Signal visualization during nasal and mouth breathing.
Figure 6. Signal visualization during nasal and mouth breathing.CC BY · PubMed Central
Figure 7. Signal visualization versus head position. On the right, the face, as viewed from the sensor.
Figure 7. Signal visualization versus head position. On the right, the face, as viewed from the sensor.CC BY · PubMed Central
Figure 8. Signal visualization during large and rapid subject movements.
Figure 8. Signal visualization during large and rapid subject movements.CC BY · PubMed Central
Figure 9. Frequency response of the IIR elliptic filter.
Figure 9. Frequency response of the IIR elliptic filter.CC BY · PubMed Central
Figure 10. Residual analysis: plot of the residual value of typical breathing data for different cutoff frequencies. The optimal cutoff is chosen at the point where noise contribution equals signal contribution.
Figure 10. Residual analysis: plot of the residual value of typical breathing data for different cutoff frequencies. The optimal cutoff is chosen at the point where noise contribution equals signal contribution.CC BY · PubMed Central
Figure 11. Frequency response of the Butterworth lowpass filter used for the breathing signal.
Figure 11. Frequency response of the Butterworth lowpass filter used for the breathing signal.CC BY · PubMed Central
Figure 12. Typical breathing signal versus time (s). Arbitrary unit.
Figure 12. Typical breathing signal versus time (s). Arbitrary unit.CC BY · PubMed Central
Figure 13. Breathing and movement combination. Rapid motions widen the spectrum and impede breathing detection. The single hatched area corresponds to the frequencies from where the movement signal is computed.
Figure 13. Breathing and movement combination. Rapid motions widen the spectrum and impede breathing detection. The single hatched area corresponds to the frequencies from where the movement signal is computed.CC BY · PubMed Central
Figure 14. Breathing and movement signals. The movement signal (green; linear scale) increases when the patient changes position. The breathing signal (blue) shows expirations and four apneas. When the movement signal increases the breathing signal is meaningless.
Figure 14. Breathing and movement signals. The movement signal (green; linear scale) increases when the patient changes position. The breathing signal (blue) shows expirations and four apneas. When the movement signal increases the breathing signal is meaningless.CC BY · PubMed Central
Figure 15. Correspondence between the received spectrum and a nasal cannula signal.
Figure 15. Correspondence between the received spectrum and a nasal cannula signal.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Research works printed but not linked: 3

  1. Kelkar, 2004, Development of movement artefacts free breathing monitor, J. Instrum. Soc. India, 38, 34
  2. Avalur, D.S. (2013). Human Breath Detection using a Microphone. [M.Sc. Thesis, University of Groningen].
  3. Obukhov, 1953, Effect of weak inhomogeneities in the atmosphere on sound and light propagation, Izv. Akad. Nauk. Seriya Geofiz., 2, 155

Cited by

See all 104

Metadata

Authors
Arlotto, P., Grimaldi, M., Naeck, R., & Ginoux, J.-M.
Affiliations
  • Université de Toulon (FR)
  • Centre Hospitalier Intercommunal Toulon-La Seyne-sur-Mer (FR)
  • Centre National de la Recherche Scientifique (FR)
Corresponding author
Arlotto, Philippe
Venue
Sensors
Publisher
MDPI AG
Published
2014-08-20
Volume
14
Issue
8
Pages
15371-15386
ISSN
1424-8220 (ISSN-L)
OpenAlex
W2005774119
Cited by
102
References
19
Citations by year
2026: 4 · 2025: 4 · 2024: 8 · 2023: 10 · 2022: 9 · 2021: 11 · 2020: 15 · 2019: 12 · 2018: 9 · 2017: 6 · 2016: 7 · 2015: 7
FWCI
3.46
Type
journal article
Language
en
Open access
Locations
  • Sensors (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • HAL (submittedVersion, other-oa)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Physical Sciences › Physics and Astronomy › Instrumentation › Flow Measurement and Analysis
Keywords
respiratory monitoring, contactless sensors, ultrasonic sensors, Doppler shift, apnea, sleep-disordered breathing, polysomnography, breathing detection, signal processing, non-invasive monitoring
MeSH terms
Humans, Monitoring, Physiologic, Sleep Apnea Syndromes, Ultrasonics, Polysomnography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An Ultrasonic Contactless Sensor for Breathing Monitoring. https://app.cochat.ai/papers/10.3390/s140815371
The paper
Arlotto, P., Grimaldi, M., Naeck, R., & Ginoux, J.-M. (2014). An Ultrasonic Contactless Sensor for Breathing Monitoring. Sensors. https://doi.org/10.3390/s140815371

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.