WearBreathing: Real World Respiratory Rate Monitoring Using Smartwatches
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Respiratory rate is a vital physiological signal that may be useful for a multitude of clinical applications, especially if measured in the wild rather than controlled settings. In-the-wild respiratory rate monitoring is currently done using dedicated chest band sensors, but these devices are specialized, expensive and cumbersome to wear day after day. While recent works have proposed using smartwatch based accelerometer and gyroscope data for respiratory rate monitoring, current methods are unreliable and inaccurate in the presence of motion and have therefore only been applied in controlled or low-motion settings. Thus, measuring respiratory rate in the wild remains a challenge. We observe that for many applications, having fewer accurate readings is better than having more, less accurate readings. Based on this, we develop WearBreathing, a novel system for respiratory rate monitoring. WearBreathing consists of a machine learning based filter that detects and rejects sensor data that are not suitable for respiratory rate extraction and a convolutional neural network model for extracting respiratory rate from accelerometer and gyroscope data. Using a diverse, out-of-the-lab dataset that we collected, we show that WearBreathing has a 2.5 to 5.8 times lower mean absolute error (MAE) than existing approaches. We show that WearBreathing is tunable and by changing a single threshold value, it can, for example, deliver a reading every 50 seconds with a MAE of 2.05 breaths/min or a reading every 5 minutes with an MAE of 1.09 breaths/min. Finally, we evaluate power consumption and find that with some power saving measures, WearBreathing can run on a smartwatch while providing a full day's worth of battery life.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adam: A Method for Stochastic Optimization
Kingma, D. P., & Ba, J. (2014) · arXiv · doi:10.48550/arxiv.1412.6980 · Cited by 98,946
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Respiratory rate predicts cardiopulmonary arrest for internal medicine inpatients.
Fieselmann, J. F., Hendryx, M. S., Helms, C. M., & Wakefield, D. S. (1993) · Journal of General Internal Medicine · doi:10.1007/bf02600071 · Cited by 399 · cited 2×
“[10] reported that a respiratory rate over 27 breaths/minute was a significant predictor of cardiac arrest.”
Dehkordi, P., Garde, A., Molavi, B., Ansermino, J. M., & Dumont, G. A. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00948 · Cited by 66
Cited by
Kwon, H., Tong, C., Haresamudram, H., Gao, Y., Abowd, G. D., Lane, N. D., & Plötz, T. (2020) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3411841 · Cited by 152
IMUGPT 2.0: Language-Based Cross Modality Transfer for Sensor-Based Human Activity Recognition
Leng, Z., Bhattacharjee, A., Rajasekhar, H., Zhang, L., Bruda, E., Kwon, H., & Plötz, T. (2024) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3678545 · Cited by 61
“An LLM automatically generates textual descriptions of activities, which are then converted into motion sequences by a motion synthesis model.”
Approaching the Real-World: Supporting Activity Recognition Training with Virtual IMU Data
Kwon, H., Wang, B., Abowd, G. D., & Plötz, T. (2021) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3478096 · Cited by 48
“Its applications include, for example, continuous monitoring of human well-being in everyday life scenarios [1, 9, 56, 85, 114].”
BackgroundLeng, Z., Kwon, H., & Ploetz, T. (2023) · Proceedings of the 2023 International Symposium on Wearable Computers · doi:10.1145/3594738.3611361 · Cited by 39
“3611361 fitness, analyzing health-related behavior, and improving industrial processes [2, 4, 14, 23].”
BackgroundInvestigating Enhancements to Contrastive Predictive Coding for Human Activity Recognition
Haresamudram, H., Essa, I., & Plötz, T. (2023) · 2023 IEEE International Conference on Pervasive Computing and Communications (PerCom) · doi:10.1109/percom56429.2023.10099197 · Cited by 27
Metadata
- Authors
- Liaqat, D., Abdalla, M., Abed-Esfahani, P., Gabel, M., Son, T., Wu, R., Gershon, A., Rudzicz, F., & Lara, E. D.
- Venue
- Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Published
- 2019-06-21
- Volume
- 3
- Issue
- 2
- Pages
- 1-22
- ISSN
- 2474-9567 (ISSN-L)
- OpenAlex
- W2955745546
- Cited by
- 58
- References
- 4
- FWCI
- 2.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.