The DOI matches its Crossref record; 64 of the 64 references it cites were found in a registry or an index.
FarSense: Pushing the Range Limit of WiFi-based Respiration Sensing with CSI Ratio of Two Antennas
Open accessAbstract
The past few years have witnessed the great potential of exploiting channel state information retrieved from commodity WiFi devices for respiration monitoring. However, existing approaches only work when the target is close to the WiFi transceivers and the performance degrades significantly when the target is far away. On the other hand, most home environments only have one WiFi access point and it may not be located in the same room as the target. This sensing range constraint greatly limits the application of the proposed approaches in real life. This paper presents FarSense--the first real-time system that can reliably monitor human respiration when the target is far away from the WiFi transceiver pair. FarSense works well even when one of the transceivers is located in another room, moving a big step towards real-life deployment. We propose two novel schemes to achieve this goal: (1) Instead of applying the raw CSI readings of individual antenna for sensing, we employ the ratio of CSI readings from two antennas, whose noise is mostly canceled out by the division operation to significantly increase the sensing range; (2) The division operation further enables us to utilize the phase information which is not usable with one single antenna for sensing. The orthogonal amplitude and phase are elaborately combined to address the "blind spots" issue and further increase the sensing range. Extensive experiments show that FarSense is able to accurately monitor human respiration even when the target is 8 meters away from the transceiver pair, increasing the sensing range by more than 100%.1 We believe this is the first system to enable through-wall respiration sensing with commodity WiFi devices and the proposed method could also benefit other sensing applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Time Series Analysis: Forecasting and Control.
Anderson, O. D., Box, G. E. P., & Jenkins, G. M. (1978) · The Statistician · doi:10.2307/2988198 · Cited by 5,298
Spectral Analysis of Signals: The Missing Data Case
Wang, Y., Li, J., & Stoica, P. (2005) · Synthesis Lectures on Signal Processing · doi:10.1007/978-3-031-02525-9 · Cited by 2,890
Tool release: gathering 802.11n traces with channel state information
Halperin, D., Hu, W., Sheth, A., & Wetherall, D. (2011) · ACM SIGCOMM Computer Communication Review · doi:10.1145/1925861.1925870 · Cited by 1,761
SpotFi: Decimeter Level Localization Using WiFi
Kotaru, M., Joshi, K., Bharadia, D., & Katti, S. (2015) · Proceedings of the 2015 ACM Conference on Special Interest Group on Data Communication · doi:10.1145/2785956.2787487 · Cited by 1,169
Understanding and Modeling of WiFi Signal Based Human Activity Recognition
Wang, W., Liu, A. X., Shahzad, M., Ling, K., & Lu, S. (2015) · Proceedings of the 21st Annual International Conference on Mobile Computing and Networking · doi:10.1145/2789168.2790093 · Cited by 1,110
Smart Homes that Monitor Breathing and Heart Rate
Adib, F., Mao, H., Kabelac, Z., Katabi, D., & Miller, R. C. (2015) · Proceedings of the 33rd Annual ACM Conference on Human Factors in Computing Systems · doi:10.1145/2702123.2702200 · Cited by 916
A Review on Recent Advances in Doppler Radar Sensors for Noncontact Healthcare Monitoring
Li, C., Lubecke, V. M., Boric-Lubecke, O., & Lin, J. (2013) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2013.2256924 · Cited by 821
Decimeter-level localization with a single WiFi access point
Vasisht, D., Kumar, S., & Katabi, D. (2016) · Networked Systems Design and Implementation · Cited by 719
Adib, F., & Katabi, D. (2013) · Proceedings of the ACM SIGCOMM 2013 conference on SIGCOMM · doi:10.1145/2486001.2486039 · Cited by 698
Droitcour, A. D., Boric-Lubecke, O., Lubecke, V. M., Lin, J., & Kovacs, G. T. A. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.823552 · Cited by 662
Cited by
Enabling Joint Communication and Radar Sensing in Mobile Networks—A Survey
Zhang, J. A., Rahman, M. L., Wu, K., Huang, X., Guo, Y. J., Chen, S., & Yuan, J. (2022) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2021.3122519 · Cited by 1,091
Integrated Sensing and Communications: Recent Advances and Ten Open Challenges
Lu, S., Liu, F., Li, Y., Zhang, K., Huang, H., Zou, J., Li, X., Dong, Y., Dong, F., Zhu, J., et al. (2024) · IEEE Internet of Things Journal · doi:10.1109/jiot.2024.3361173 · Cited by 516
A Survey on Human Behavior Recognition Using Channel State Information
Wang, Z., Jiang, K., Hou, Y., Dou, W., Zhang, C., Huang, Z., & Guo, Y. (2019) · IEEE Access · doi:10.1109/access.2019.2949123 · Cited by 149
Metadata
- Authors
- Zeng, Y., Wu, D., Xiong, J., Yi, E., Gao, R., & Zhang, D.
- Venue
- Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Published
- 2019-09-09
- Volume
- 3
- Issue
- 3
- Pages
- 1-26
- ISSN
- 2474-9567 (ISSN-L)
- OpenAlex
- W2962319395
- Cited by
- 469
- References
- 64
- FWCI
- 11.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.