CoChat

Doctor's Dilemma: Evaluating an Explainable Subtractive Spatial Lightweight Convolutional Neural Network for Brain Tumor Diagnosis

Kumar, Ambeshwar, Manikandan, Ramachandran, Kose, Utku, Gupta, Deepak, Satapathy, Suresh C. · 2021 · ACM Transactions on Multimedia Computing, Communications, and Applications
Cited by 39

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

In Medicine Deep Learning has become an essential tool to achieve outstanding diagnosis on image data. However, one critical problem is that Deep Learning comes with complicated, black-box models so it is not possible to analyze their trust level directly. So, Explainable Artificial Intelligence (XAI) methods are used to build additional interfaces for explaining how the model has reached the outputs by moving from the input data. Of course, that's again another competitive problem to analyze if such methods are successful according to the human view. So, this paper comes with two important research efforts: (1) to build an explainable deep learning model targeting medical image analysis, and (2) to evaluate the trust level of this model via several evaluation works including human contribution. The target problem was selected as the brain tumor classification, which is a remarkable, competitive medical image-based problem for Deep Learning. In the study, MR-based pre-processed brain images were received by the Subtractive Spatial Lightweight Convolutional Neural Network (SSLW-CNN) model, which includes additional operators to reduce the complexity of classification. In order to ensure the explainable background, the model also included Class Activation Mapping (CAM). It is important to evaluate the trust level of a successful model. So, numerical success rates of the SSLW-CNN were evaluated based on the peak signal-to-noise ratio (PSNR), computational time, computational overhead, and brain tumor classification accuracy. The objective of the proposed SSLW-CNN model is to obtain faster and good tumor classification with lesser time. The results illustrate that the SSLW-CNN model provides better performance of PSNR which is enhanced by 8%, classification accuracy is improved by 33%, computation time is reduced by 19%, computation overhead is decreased by 23%, and classification time is minimized by 13%, as compared to state-of-the-art works. Because the model provided good numerical results, it was then evaluated in terms of XAI perspective by including doctor-model based evaluations such as feedback CAM visualizations, usability, expert surveys, comparisons of CAM with other XAI methods, and manual diagnosis comparison. The results show that the SSLW-CNN provides good performance on brain tumor diagnosis and ensures a trustworthy solution for the doctors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1145/3457187

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 39

Metadata

Authors
Kumar, A., Manikandan, R., Kose, U., Gupta, D., & Satapathy, S. C.
Venue
ACM Transactions on Multimedia Computing, Communications, and Applications
Published
2021-10-26
Volume
17
Issue
3s
Pages
1-26
ISSN
  • 1551-6857 (ISSN-L)
  • 1551-6865
OpenAlex
W3211024110
Cited by
39
References
10
FWCI
1.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Doctor's Dilemma: Evaluating an Explainable Subtractive Spatial Lightweight Convolutional Neural Network for Brain Tumor Diagnosis. https://app.cochat.ai/papers/10.1145/3457187
The paper
Kumar, A., Manikandan, R., Kose, U., Gupta, D., & Satapathy, S. C. (2021). Doctor's Dilemma: Evaluating an Explainable Subtractive Spatial Lightweight Convolutional Neural Network for Brain Tumor Diagnosis. ACM Transactions on Multimedia Computing, Communications, and Applications. https://doi.org/10.1145/3457187

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.