A study in interactive 3-D rotation using 2-D control devices
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This paper describes and evaluates the design of four virtual controllers for use in rotating three-dimensional objects using the mouse. Three of four of these controllers are "new" in that they extend traditional direct manipulation techniques to a 3-D environment. User performance is compared during simple and complex rotation tasks. The results indicate faster performance for complex rotations using the new continuous axes controllers compared to more traditional slider approaches. No significant differences in accuracy for complex rotations were found across the virtual controllers.A second study compared the best of these four virtual controllers (the Virtual Sphere) to a control device by Evans, Tanner and Wein. No significant differences either in time to complete rotation task or accuracy of performance were found. All but one subject indicated they preferred the Virtual Sphere because it seemed more "natural".
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
There's More to Interaction Than Meets the Eye: Some Issues in Manual Input
BUXTON, W. (1986) · User Centered System Design · doi:10.1201/b15703-15 · Cited by 167
Tablet-based valuators that provide one, two, or three degrees of freedom
Evans, K. B., Tanner, P. P., & Wein, M. (1981) · ACM SIGGRAPH Conference (SIGGRAPH) · doi:10.1145/800224.806794 · Cited by 62
Cited by
Fitts' Law as a Research and Design Tool in Human-Computer Interaction
MacKenzie, I. S. (1992) · Human–Computer Interaction · doi:10.1207/s15327051hci0701_3 · Cited by 1,637
QuickTime VR: an image-based approach to virtual environment navigation
Chen, S. E. (1995) · Proceedings of the 22nd annual conference on Computer graphics and interactive techniques - SIGGRAPH '95 · doi:10.1145/218380.218395 · Cited by 1,160
Macmolplt: a graphical user interface for GAMESS
Bode, B. M., & Gordon, M. S. (1998) · Journal of Molecular Graphics and Modelling · doi:10.1016/s1093-3263(99)00002-9 · Cited by 1,125
Simulating Humans: Computer Graphics, Animation, and Control
Badler, N. I., Phillips, C. B., & Webber, B. L. (1993) · Oxford University Press eBooks · doi:10.1093/oso/9780195073591.001.0001 · Cited by 751
SKETCH: an interface for sketching 3D scenes
Zeleznik, R. C., Herndon, K. P., & Hughes, J. F. (2006) · ACM SIGGRAPH 2006 Courses on - SIGGRAPH '06 · doi:10.1145/1185657.1185770 · Cited by 650
Metadata
- Authors
- Chen, M., Mountford, S. J., & Sellen, A.
- Venue
- ACM SIGGRAPH Computer Graphics
- Published
- 1988-06
- Volume
- 22
- Issue
- 4
- Pages
- 121-129
- ISSN
- 0097-8930 (ISSN-L)
- OpenAlex
- W2153079896
- Cited by
- 317
- References
- 2
- FWCI
- 14.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.