The DOI matches its Crossref record.
Room temperature ionic liquids as novel media for ‘clean’ liquid–liquid extraction
Abstract
The partitioning of simple, substituted-benzene derivatives between water and the room temperature ionic liquid, butylmethylimidazolium hexafluorophosphate, is based on the solutes’ charged state or relative hydrophobicity; room temperature ionic liquids thus may be suitable candidates for replacement of volatile organic solvents in liquid–liquid extraction processes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 12
- T. C. Lo, in Handbook of Separations Techniques for Chemical Engineers, ed. P. A. Schwietzer, McGraw-Hill, New York, 1996, pp. 1-450–1-529
- J. Rydberg, C.Musikas and G. R.Choppin, Principles and Practices of Solvent Extraction, Marcel Dekker, New York, 1992
- Seddon, 1997, J. Chem. Technol. Biotechnol., 68, 351, 10.1002/(SICI)1097-4660(199704)68:4<351::AID-JCTB613>3.0.CO;2-4 · DOI · Paper page
- Chauvin, 1995, CHEMTECH, 25, 26
- Hussey, 1988, Pure Appl. Chem., 60, 1763, 10.1351/pac198860121763 · DOI · Paper page
- Wilkes, 1992, J. Chem. Soc., Chem. Commun., 965, 10.1039/c39920000965 · DOI · Paper page
- Fuller, 1994, J. Chem. Soc., Chem. Commun., 299, 10.1039/c39940000299 · DOI · Paper page
- Wilkes, 1982, Inorg. Chem., 21, 1263, 10.1021/ic00133a078 · DOI · Paper page
- C. Hansch, A.Leo and D.Hoekman, Exploring QSAR Hydrophobic, Electronic and Steric Constants, American Chemical Society, Washington, DC, 1995
- Leahy, 1992, J. Chem. Soc., Perkin Trans. 2, 723, 10.1039/P29920000723 · DOI
- Leahy, 1992, J. Chem. Soc., Perkin Trans. 2, 705, 10.1039/P29920000705 · DOI
- J. G. Huddleston, S. T.Griffin, J.Zhang, H. D.Willauer and R. D.Rogers, in Aqueous Two-Phase Systems, ed. R. Kaul in Methods in Biotechnology, ed. J. M. Walker, Humana Press, Totowa, NJ, 1998, in press
Cited by
Carbon capture and storage (CCS): the way forward
Bui, M., Adjiman, C. S., Bardow, A., Anthony, E. J., Boston, A., Brown, S., Fennell, P. S., Fuss, S., Galindo, A., Hackett, L. A., et al. (2018) · Energy & Environmental Science · doi:10.1039/c7ee02342a · Cited by 4,374
Beyond Mechanical Recycling: Giving New Life to Plastic Waste
Vollmer, I., Jenks, M. J. F., Roelands, M. C. P., White, R. J., van Harmelen, T., de Wild, P., van der Laan, G. P., Meirer, F., Keurentjes, J. T. F., & Weckhuysen, B. M. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.201915651 · Cited by 1,905
Ionic liquids and catalysis: Recent progress from knowledge to applications
Olivier-Bourbigou, H., Magna, L., & Morvan, D. (2010) · Applied Catalysis A: General · doi:10.1016/j.apcata.2009.10.008 · Cited by 1,639
Use of ionic liquids as ‘green’ solvents for extractions
Zhao, H., Xia, S., & Ma, P. (2005) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.1333 · Cited by 873
Multiscale Studies on Ionic Liquids
Dong, K., Liu, X., Dong, H., Zhang, X., & Zhang, S. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00776 · Cited by 773
Metadata
- Authors
- Huddleston, J. G., Willauer, H. D., Swatloski, R. P., Visser, A. E., & Rogers, R. D.
- Venue
- Chem. Commun.
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 1998
- Issue
- 16
- Pages
- 1765-1766
- ISSN
- 1359-7345 (ISSN-L)
- 1364-548X
- OpenAlex
- W2088379574
- Cited by
- 2,167
- References
- 0
- FWCI
- 12.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Room temperature ionic liquids as novel media for ‘clean’ liquid–liquid extraction. https://app.cochat.ai/papers/10.1039/a803999b
- The paper
- Huddleston, J. G., Willauer, H. D., Swatloski, R. P., Visser, A. E., & Rogers, R. D. (1998). Room temperature ionic liquids as novel media for ‘clean’ liquid–liquid extraction. Chem. Commun. https://doi.org/10.1039/a803999b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.