Doped Oxides for High-Temperature Luminescence and Lifetime Thermometry
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
The measurement of high temperatures in oxides and oxide-based structures in practical applications often presents challenges including steep thermal gradients, the presence of flames or chemically aggressive environments, and the transparency or translucency of most oxides. For turbine engines, oxide coatings are of great commercial importance, and the rapid motion of parts prohibits contact thermometry. Luminescence thermometry offers a number of advantages for measuring temperature in such systems and has been the subject of ongoing study for many years. Recent work on rare-earth-doped thermal barrier coatings, environmental barrier coatings, and related oxides has demonstrated the feasibility of luminescence thermometry to temperatures well in excess of 1000°C. The luminescent properties of these materials and the analytical techniques used to extract reproducible temperature measurements from the measured luminescence are reviewed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Shannon, R. D. (1976) · Acta Crystallographica Section A · doi:10.1107/s0567739476001551 · Cited by 66,145 · cited 1×
“The rare-earth ions substitute for Y3+ because of the similarity in ionic radii (36, 37), but unlike in YSZ, they occupy inherently low-symmetry sites in these materials [C1 and C2 sites for the X2 phase of Y2SiO5, C1 and Ci for D-type Y2Si2O7 (38–40)].”
BackgroundEffective ionic radii in oxides and fluorides
Shannon, R. D., & Prewitt, C. T. (1969) · Acta Crystallographica Section B Structural Crystallography and Crystal Chemistry · doi:10.1107/s0567740869003220 · Cited by 8,627
Optical Absorption Intensities of Rare-Earth Ions
Judd, B. R. (1962) · Physical Review · doi:10.1103/physrev.127.750 · Cited by 8,105
Intensities of Crystal Spectra of Rare-Earth Ions
Ofelt, G. S. (1962) · The Journal of Chemical Physics · doi:10.1063/1.1701366 · Cited by 7,526
The energy gap law for radiationless transitions in large molecules
Englman, R., & Jortner, J. (1970) · Molecular Physics · doi:10.1080/00268977000100171 · Cited by 2,778 · cited 1×
“A multidimensional quantum mechanical treatment of the process has been made (90), and the rate equation for this process is WCT(T ) = W0T ∗−1/2 exp(−Ea/kT ∗), 7a.”
Time-Correlated Single Photon Counting
(1984) · Elsevier eBooks · doi:10.1016/b978-0-12-524140-3.x5001-1 · Cited by 2,550
Theory of Concentration Quenching in Inorganic Phosphors
Dexter, D. L., & Schulman, J. H. (1954) · The Journal of Chemical Physics · doi:10.1063/1.1740265 · Cited by 2,253
Spectra and Energy Levels of Rare Earth Ions in Crystals
Goodwin, D. W. (1969) · Physics Bulletin · doi:10.1088/0031-9112/20/12/010 · Cited by 1,648
Spectra and Energy Levels of Rare Earth Ions in Crystals
Dieke, G. H., & Satten, R. A. (1970) · American Journal of Physics · doi:10.1119/1.1976350 · Cited by 1,520
Review of temperature measurement
Childs, P., Greenwood, J. R., & Long, C. A. (2000) · Review of Scientific Instruments · doi:10.1063/1.1305516 · Cited by 980
Systematic behaviour in trivalent lanthanide charge transfer energies
Dorenbos, P. (2003) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/15/49/018 · Cited by 659
Krämer, S., Yang, J., Levi, C. G., & Johnson, C. A. (2006) · Journal of the American Ceramic Society · doi:10.1111/j.1551-2916.2006.01209.x · Cited by 642
Effect of Dopants on Zirconia Stabilization—An X‐ray Absorption Study: I, Trivalent Dopants
Li, P., Chen, I., & Penner‐Hahn, J. E. (1994) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.1994.tb06964.x · Cited by 578
Advanced Ceramic Materials for High Temperature Applications
Belmonte, M. (2006) · Advanced Engineering Materials · doi:10.1002/adem.200500269 · Cited by 283
Oxide Materials with Low Thermal Conductivity
Winter, M. R., & Clarke, D. R. (2007) · Journal of the American Ceramic Society · doi:10.1111/j.1551-2916.2006.01410.x · Cited by 268
Self-citationBazzi, R., Flores, M. A., Louis, C., Lebbou, K., Zhang, W., Dujardin, C., Roux, S., Mercier, B., Ledoux, G., Bernstein, E., et al. (2004) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2003.10.031 · Cited by 200
Naccache, R., Vetrone, F., Speghini, A., Bettinelli, M., & Capobianco, J. A. (2008) · The Journal of Physical Chemistry C · doi:10.1021/jp711494d · Cited by 135
Cation self-diffusion of Ca44, Y88, and Zr96 in single-crystalline calcia- and yttria-doped zirconia
Kilo, M., Taylor, M. A., Argirusis, C., Borchardt, G., Lesage, B., Weber, S., Scherrer, S., Scherrer, H., Schroeder, M., & Martin, M. (2003) · Journal of Applied Physics · doi:10.1063/1.1628379 · Cited by 129
Decay pathway and high-temperature luminescence of Eu3+ in Ca2Gd8Si6O26
Chambers, M. D., Rousseve, P. A., & Clarke, D. R. (2008) · Journal of Luminescence · doi:10.1016/j.jlumin.2008.10.008 · Cited by 93
Self-citationConcepts for luminescence sensing of thermal barrier coatings
Gentleman, M. M., & Clarke, D. R. (2004) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2004.08.005 · Cited by 93
Self-citationMultiphonon and energy transfer relaxation in charge compensated crystals
Miller, M. P., & Wright, J. C. (1979) · The Journal of Chemical Physics · doi:10.1063/1.438074 · Cited by 69
Thermal quenching of luminescence and isovalent trap model for rare‐earth‐ion‐doped AlN
Łożykowski, H. J., & Jadwisienczak, W. M. (2007) · physica status solidi (b) · doi:10.1002/pssb.200642152 · Cited by 63
Hess, N. J., & Schiferl, D. (1990) · Journal of Applied Physics · doi:10.1063/1.346593 · Cited by 55
High caesarean section rates among women over 30
Marwick, J. C., & Lynn, R. (2001) · BMJ · doi:10.1136/bmj.323.7307.284 · Cited by 20
Cited by
Darolia, R. (2013) · International Materials Reviews · doi:10.1179/1743280413y.0000000019 · Cited by 748
Standardizing luminescence nanothermometry for biomedical applications
Bednarkiewicz, A., Marciniak, L., Carlos, L. D., & Jaque, D. (2020) · Nanoscale · doi:10.1039/d0nr03568h · Cited by 411
Optical temperature sensing of up-conversion luminescent materials: Fundamentals and progress
Zhao, Y., Wang, X., Zhang, Y., Li, Y., & Yao, X. (2020) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2019.152691 · Cited by 380
Sensing temperature via downshifting emissions of lanthanide-doped metal oxides and salts. A review
Dramićanin, M. D. (2016) · Methods and Applications in Fluorescence · doi:10.1088/2050-6120/4/4/042001 · Cited by 348
Thermographic phosphors for thermometry: A survey of combustion applications
Aldén, M., Omrane, A., Richter, M., & Särner, G. (2011) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2010.07.001 · Cited by 325
Metadata
- Authors
- Chambers, M. D., & Clarke, D. R.
- Venue
- Annual Review of Materials Research
- Publisher
- Annual Reviews
- Published
- 2009-08-01
- Volume
- 39
- Issue
- 1
- Pages
- 325-359
- ISSN
- 1531-7331 (ISSN-L)
- 1545-4118
- OpenAlex
- W2135605669
- Cited by
- 281
- References
- 24
- FWCI
- 2.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.