The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Optical temperature sensing of up-conversion luminescent materials: Fundamentals and progress
Abstract
Abstract Temperature monitoring plays an important role in ensuring product quality, saving energy, promoting the development of national economy and providing basic diagnostic criteria in the field of biomedicine. Due to the importance and universality of temperature measurement, the study of temperature sensing property and the pursuit of high sensitivity have become an important research field of rare-earth luminescent materials in recent years, and have received extensive attention. In this paper, different optical temperature sensing methods and principles, the application of rare-earth luminescent materials in optical temperature sensing, and the types of up-conversion luminescent thermometry materials are reviewed. First, we introduce that optical thermometry can realize non-contact temperature measurement, large-scale imaging, wide dynamic range and rapid response in biological fluorescent tag, accurate measurement of local temperature in medical treatment, and direct temperature measurement of an inaccessible object, which has a very broad application prospect. Meanwhile, we emphasize that the fluorescence intensity ratio technique based on the thermally coupled levels of rare-earth ions has been considered as a reliable and promising non-contact optical temperature sensing method due to its high accuracy and reliability. In the later sections, we review the fundamentals and research progress of rare-earth luminescent materials in optical temperature sensing. Double-doped up-conversion thermometry materials with diverse activators and Yb3+ as sensitizers are mainly introduced, as well as tri-doped multi-color optical thermometry materials. Finally, we summarize the current research results and discuss further research directions on the basis of their current developments. It is hoped that this review could provide new inspiration for the subsequent novel temperature sensors in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Second window for in vivo imaging
Smith, A. M., Mancini, M. C., & Nie, S. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.326 · Cited by 2,848
Exposure Modeling of Engineered Nanoparticles in the Environment
Mueller, N. C., & Nowack, B. (2008) · Environmental Science & Technology · doi:10.1021/es7029637 · Cited by 1,828
Tuning upconversion through energy migration in core–shell nanoparticles
Wang, F., Deng, R., Wang, J., Wang, Q., Han, Y., Zhu, H., Chen, X., & Liu, X. (2011) · Nature Materials · doi:10.1038/nmat3149 · Cited by 1,795
Luminescent probes and sensors for temperature
Wang, X.-D., Wolfbeis, O. S., & Meier, R. J. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60102a · Cited by 1,647
Self-citationControlling upconversion nanocrystals for emerging applications
Zhou, B., Shi, B., Jin, D., & Liu, X. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.251 · Cited by 1,503
Gai, S., Li, C., Yang, P., & Lin, J. (2014) · Chemical Reviews · doi:10.1021/cr4001594 · Cited by 1,460
A systematic analysis of the spectra of the lanthanides doped into single crystal LaF3
Carnall, W. T., Goodman, G. L., Rajnak, K., & Rana, R. S. (1989) · The Journal of Chemical Physics · doi:10.1063/1.455853 · Cited by 1,239
Okabe, K., Inada, N., Gota, C., Harada, Y., Funatsu, T., & Uchiyama, S. (2012) · Nature Communications · doi:10.1038/ncomms1714 · Cited by 1,203
Dong, B., Cao, B., He, Y., Liu, Z., Li, Z., & Feng, Z. (2012) · Advanced Materials · doi:10.1002/adma.201200431 · Cited by 811
Upconverting nanoparticles: assessing the toxicity
Gnach, A., Lipinski, T., Bednarkiewicz, A., Rybka, J., & Capobianco, J. A. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00177j · Cited by 652
Cited by
Duarah, R., Torné‐Morató, H., Zhang, G., Amin, Y., Pabast, M., Sharma, N., He, S., Das, M. R., & Pompa, P. P. (2026) · Advanced Healthcare Materials · doi:10.1002/adhm.202504419 · Cited by 24
Metadata
- Authors
- Zhao, Y., Wang, X., Zhang, Y., Li, Y., & Yao, X.
- Venue
- Journal of Alloys and Compounds
- Publisher
- Elsevier BV
- Published
- 2020-03
- Volume
- 817
- Pages
- 152691
- ISSN
- 0925-8388 (ISSN-L)
- OpenAlex
- W2981186509
- Cited by
- 380
- References
- 43
- FWCI
- 10.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical temperature sensing of up-conversion luminescent materials: Fundamentals and progress. https://app.cochat.ai/papers/10.1016/j.jallcom.2019.152691
- The paper
- Zhao, Y., Wang, X., Zhang, Y., Li, Y., & Yao, X. (2020). Optical temperature sensing of up-conversion luminescent materials: Fundamentals and progress. Journal of Alloys and Compounds. https://doi.org/10.1016/j.jallcom.2019.152691
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.